Air King 9218 Bruksanvisning
Läs gratis den bruksanvisning för Air King 9218 (6 sidor) i kategorin Fläkt. Guiden har ansetts hjälpsam av 4 personer och har ett genomsnittsbetyg på 4.6 stjärnor baserat på 2.5 recensioner. Har du en fråga om Air King 9218 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/6

Rev. C 11/24
1
5085468
IMPORTANT INSTRUCTIONS - OPERATING MANUAL
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE,
INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD
RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
FLOOR/TABLE FAN
12" (30,5 cm) MODEL 9212 29WK54
14" (35,5 cm) MODEL 9214 1VN44
18" (45,7 cm) MODEL 9218 36L464
Commercial Style fan
WARNING: This fan should be used only in a
clean, dry environment. Mounting of this product
in any way other than specied in the instruction
sheet will null and void the manufacturers warranty.
It is not intended to be used in agricultural settings.

Rev. C 11/24
2
5085468
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INFORMATION
When using electrical appliances, basic precautions should always be followed to reduce
the risk of fire, electrical shock and injury to persons, including the following:
Read all instructions before using this Fan.
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR PERSONAL INJURY, ALWAYS
FOLLOW THESE IMPORTANT SAFETY INSTRUCTIONS AND WARNINGS:
DO NOT use this fan to ventilate areas where flammable liquids or vapors are used, stored or are present, including paints,
gasoline, varnishes, floor refinishing products or solvents. ALWAYS read and follow all warnings and instructions on the
containers for these products!
ALWAYS be sure the plug fits tightly into the outlet. When plugs fit loosely into outlets, they may slip partially out of the outlet
and create a poor connection. This may cause outlets to overheat and create a potential fire hazard. Outlets in this condition
should be replaced by a qualified electrician.
ALWAYS unplug the power cord when servicing, cleaning or moving the Fan. DO NOT use the ON/OFF switch as the sole
means of disconnecting power. NEVER leave children unattended when the Fan is on or plugged in. ALWAYS turn off and
unplug the Fan when not in use.
BE CERTAIN that the power source for the Fan is 120V AC. DO NOT plug the Fan into 240V or other power source.
The Blue Plug™ on your AirKing fan is a safety feature. It contains a non-replaceable safety device (fuse) that should not be removed
or tampered with. To reduce the risk of fire, electric shock and personal injury, DO NOT attempt to remove, replace, repair or tamper
with the originally supplied plug. If the Fan has stopped functioning, it may be due to the safety device incorporated in this plug.
The power cord is equipped with a three-prong grounded plug that must be inserted into a matching receptacle. Under no
circumstances should the grounding prong be cut off the plug. Where a two-prong wall receptacle is encountered, it must be
replaced with a properly grounded three-prong receptacle installed in accordance with the National Electrical Code (NEC) and
all applicable local codes and ordinances. This work must be done only by a qualified electrician, using copper wire only.
DO NOT USE A THREE-PRONG TO TWO-PRONG ADAPTER. IMPROPER CONNECTION MAY CREATE THE RISK OF
ELECTRICAL SHOCK. USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA.
WARNING: To reduce the risk of fire, electric shock, or injury to persons, do not use replacement parts that have not been
recommended by the manufacturer (e.g. parts made at home using a 3D printer).
• AVOID the use of extension cords, power strips, power taps, outlet style air fresheners or other cord connected device, as these
devices may overheat and cause a fire hazard.
• DO NOT route power cord under rugs, carpets, runners or furniture. This may damage the cord or cause it to overheat creating a fire hazard.
• ALWAYS place the Fan on a stable, flat, level surface while in operation to prevent the Fan from overturning.
• NEVER insert or allow fingers or objects to enter grill openings while Fan is in operation or injury and/or damage to the Fan may occur.
• DO NOT block, cover or obstruct air flow to or from the fan while in operation.
• DO NOT use this Fan outdoors or near water or wet locations such as a bath tub, pool or hot tub. Use of this Fan in a wet location
may create a shock hazard.
• DO NOT run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under
furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
• NEVER use a single extension cord to operate more than one Fan or other electrical device.
• DO NOT use this Fan if it has been damaged or is not functioning properly.
• THIS FAN DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 547-7 (2008).This Fan is not suitable for use in agricultural
facilities including areas where livestock, poultry or other animals are confined. Please refer to National Electric Code (NEC) Article
547-7 (2008), or applicable state or local codes or standards relating to electrical requirements for agricultural buildings.
• THIS FAN DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 500 (2008).This Fan is not suitable for use in hazardous
locations. Please refer to National Electric Code (NEC) Article 500 or applicable state or local codes or standards relating to
electrical requirements for hazardous locations.
WARNING
WARNING
CAUTION

Rev. C 11/24
3
5085468
MODEL 9212 29WK54 / 9214 1VN44 / 9218 36L464
DESCRIPTION
The AirKing floor/table fan features 3-speed rotary knob operation and a 3-paddle
fan blade. This fan has a permanently lubricated motor with a 9 ft. (2.74 m) 18/3
cord set and is constructed of sturdy, powder coated steel.
SPECIFICATIONS
Motor .........................................120 V, 60 Hz
Blade diameter ...........................12" (30,5 cm); 14" (35,5 cm); 18" (45,7 cm)
Speeds .......................................3
Control ........................................Rotary Switch
Air flow distribution .....................90°
Approvals ...................................ETL Listed. Close mesh Fan guard
meets OSHA requirements.
*Tested in accordance with AMCA standard 230-99
OPERATION
1. Plug in cord and select desired operating speed with knob on back of fan.
WARNING: THIS FAN SHOULD BE USED ONLY IN A
CLEAN, DRY ENVIRONMENT. MOUNTING OF THIS PRODUCT
IN ANY WAY OTHER THEN SPECIFIED IN THE INSTRUCTION SHEET WILL NULL
AND VOID THE MANUFACTURER’S WARRANTY.
MAINTENANCE
WARNING:
ALWAYS UNPLUG THE CORD BEFORE
MOVING OR SERVICING.
WARNING: DO NOT IMMERSE FAN IN WATER!
CLEANING: Use a soft cloth and mild soap solution such as liquid dish washing
detergent. Dry all parts completely before reconnecting to power supply.
CAUTION: DO NOT USE GASOLINE, BENZINE, THINNER,
HARSH CLEANERS, ETC. AS THEY WILL DAMAGE THE FAN. NEVER
USE ALCOHOL OR SOLVENTS.
LUBRICATION: Precision bearings are sealed at the factory for life and do not
require further lubrication.
STORAGE: Store the Fan, with these instructions, in a clean and dry place.
DISPOSITION: Corrugated packaging materials are recyclable. For
environmentally responsible disposal of this product, contact your local waste
service provider or visit www.1800recycling.com
®
.
CALIFORNIA RESIDENTS ONLY:
WARNING: THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL
[OR CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE
CANCER.
WARNING: THIS PRODUCT CAN EXPOSE YOU TO A
CHEMICAL [OR CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA
TO CAUSE REPRODUCTIVE TOXICITY.
MODEL 9212 / 29WK54
SPEED HIGH MED LOW
CFM* 1360 1170 1010
M
3
/s 0.64 0.55 0.48
RPM 1545 1205 900
Amps 0.8 0.6 0.5
Watts 85 76 64
dB A 56 49 42
*Tested in accordance with AMCA standard 230-99
MODEL 9214 / 1VN44
SPEED HIGH MED LOW
CFM* 1650 1470 1180
M
3
/s 0.77 0.68 0.55
RPM 1498 1296 934
Amps 0.6 0.5 0.4
Watts 63 56 48
dB A 58 55 48
*Tested in accordance with AMCA standard 230-99
MODEL 9218 / 36L464
SPEED HIGH MED LOW
CFM* 3190 2970 2660
M
3
/s 1.51 1.40 1.26
RPM 1500 1300 1100
Amps 1.5 1.3 1.0
Watts 180 150 125
dB A 67 58 49
Produktspecifikationer
Varumärke: | Air King |
Kategori: | Fläkt |
Modell: | 9218 |
Behöver du hjälp?
Om du behöver hjälp med Air King 9218 ställ en fråga nedan och andra användare kommer att svara dig
Fläkt Air King Manualer
10 Oktober 2024
27 September 2024
24 September 2024
23 September 2024
22 September 2024
21 September 2024
15 September 2024
14 September 2024
13 September 2024
11 September 2024
Fläkt Manualer
- Vortice
- Clatronic
- Livoo
- Rok
- Alpine
- Eurom
- Tristar
- Kalorik
- Inventum
- Café
- Crane
- Argoclima
- Stadler Form
- Eurolite
- IXL
Nyaste Fläkt Manualer
8 April 2025
8 April 2025
8 April 2025
5 April 2025
3 April 2025
2 April 2025
2 April 2025
1 April 2025
1 April 2025
1 April 2025