Läs gratis den bruksanvisning för Andrews PAC22 Series 2 (3 sidor) i kategorin Luftkonditionering. Guiden har ansetts hjälpsam av 6 personer och har ett genomsnittsbetyg på 4.5 stjärnor baserat på 3.5 recensioner. Har du en fråga om Andrews PAC22 Series 2 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/3

Click www.andrews-sykes.com
or Call Us Free 0800 211 611
PAC22 Series 2
Portable Air Conditioning
Operating Instructions
& Safety Guide
General Safety
Keep children and animals away from air conditioning units.
Never leave them alone in a room where the units in use.
This equipment should only be used by a competent person who
has read and understood these instructions.
Never operate this equipment if you are ill, feeling tired or under the
influence of alcohol or drugs.
Keep the Air Conditioning vents clear of all obstructions.
Never put anything on top of the unit or block the air outlets.
Make sure equipment is switched off and unplugged after use.
Never leave switched on or unattended.
Do not use the unit where sunlight is shining directly onto it.
Check condition of equipment before use. If unit is showing signs
of damage contact your supplier immediately.
Electrical Safety
This unit requires a 230 volt electrical supply. It plugs into a standard BS1363
domestic socket.
Always inspect plugs and leads for damage before plugging into the supply -
DO NOT USE IF ANY DAMAGE IS FOUND
Ensure cables are run as not to cause a hazard.
If an extension lead is used, ensure it is of the correct standard , and fully
uncoiled when being used.
Do not lay electrical cables in wet / damp areas.
Do not move equipment whilst operating.
Do not pull equipment by its cable.
It is recommended that electrical equipment is used via a suitable RCD.
Machine not working?
ONLY A COMPETENT ELECTRICIAN SHOULD ATTEMPT TO RECTIFY
ELECTRICAL SUPPLY PROBLEMS. DO NOT REMOVE ANY PANELS FROM THE
MACHINE.
SERIES 2
Problem Likely Cause Solution
No air flow from the
room unit
Red ‘MAINS’ light off Turn on electricity and/or check mains
supply fuse
No air flow from the
room unit
Red ‘MAINS’ light on.
White ‘DEFROST’
light on
Machine is in defrost mode, do not
adjust anything, machine will revert to
normal run after 10 mins
Insufficient air flow
from the room unit
Blocked air filter Clean filter
No cooling Green ‘COOLING’
light off
Revolve thermostat knob fully anti-
clockwise to ‘1’. Wait 10 minutes for
time delay on start-up.
No cooling Amber ‘ATTENTION’
light illuminated. High
pressure trip.
Press ‘+’ button to re-set and check for:
Lack of water flow... kinked hoses?
Shortage of water..... top up.
External heat exchanger unit mounted in
very high temperature?
Water frozen? Add glycol (33%)
External heat exchanger coil blocked
with dirt.... clean
Air cooled units.... lack of air flow from
exhaust.... kinked or blocked duct, duct
too long.
No cooling Amber ‘ATTENTION’
light illuminated. Low
pressure trip.
Press ‘-’ button to re-set and check for:
No air flow, blocked filter?
Evaporator blocked with ice. Very low air
temperature?
No cooling Amber ‘ATTENTION’
light illuminated. High
level condensate trip.
Condensate pump not reducing water
level. Kink in condensate tube between
room unit and external heat exchanger?
Leak inside room unit. Pump filter inside
room unit blocked. Condensate tube frozen
Produktspecifikationer
| Varumärke: | Andrews |
| Kategori: | Luftkonditionering |
| Modell: | PAC22 Series 2 |
Behöver du hjälp?
Om du behöver hjälp med Andrews PAC22 Series 2 ställ en fråga nedan och andra användare kommer att svara dig
Luftkonditionering Andrews Manualer
4 April 2025
25 Juli 2024
25 Juli 2024
23 Juli 2024
22 Juli 2024
22 Juli 2024
22 Juli 2024
21 Juli 2024
21 Juli 2024
21 Juli 2024
Luftkonditionering Manualer
- Evapolar
- Riffel
- Termozeta
- Midea
- Apc
- Sinclair
- Calor
- Trotec
- Avallon
- Uniprodo
- FREONIC
- Rotel
- Unold
- MRCOOL
- Qlima - Zibro
Nyaste Luftkonditionering Manualer
20 Oktober 2025
20 Oktober 2025
20 Oktober 2025
19 Oktober 2025
17 Oktober 2025
17 Oktober 2025
16 Oktober 2025
16 Oktober 2025
16 Oktober 2025
13 Oktober 2025