Barska AX11224 Bruksanvisning
Läs gratis den bruksanvisning för Barska AX11224 (2 sidor) i kategorin Valv. Guiden har ansetts hjälpsam av 18 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 9.5 recensioner. Har du en fråga om Barska AX11224 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/2

User’s Manual for Biometric Safe
A. Initialization Button
B. Battery Compartment
C. Bolts
D. Fingerprint Scanner
E. Indicator Lights
FG
A
B
D
E
H
* Actual model may vary
See reverse side for more information
9/12
BC248
1. INSTALL BATTERIES
1. Remove Battery Compartment (B) cover
2. Insert 4 AA batteries and restore battery cover
3. Bolts (C) automatically extend when batteries are inserted
To retract bolts:
- Press and release Wake-Up Button (F)
- Place any finger on the Fingerprint Scanner (D)
- Bolts will retract
2. FINGERPRINT REGISTRATION
IMPORTANT:
The safe is in Factory Default mode, ANY fingerprint can
open the safe. Only successful registered fingerprint can
terminate Factory Default mode
During registration the door must remain open and the Bolts (C)
must be in the retracted position. Otherwise, the fingerprint will
not be saved
To retract bolts:
- Press and release Wake-Up Button (F)
- Place any finger on Fingerprint Scanner (D)
- Bolts will retract
1. Press and release Initialization Button (A)
2. Immediately place a finger on the Fingerprint Scanner (D)
- Hold finger still
- 1 beep will be heard recognizing the fingerprint; followed by
2 consecutive beeps
- Remove finger
- Registration is complete
Successful Registration
Registration is successful when a total of 3 beeps are heard
Unsuccessful Registration
2 short beeps will be heard; repeat registration process again
3. To register another fingerprint – repeat steps 1 - 2
3. TEST A REGISTERED FINGERPRINT
1. With safe door open, press and release Wake-Up Button (F)
- Bolts (C) will extend
2. Press and release Wake-Up Button (F)
- Place a non-registered finger on the Fingerprint Scanner (D)
- Bolts will stay extended
3. If the bolts retract with a non-registered fingerprint,
registration was unsuccessful; and safe remains in Factory
Default mode
- Repeat steps under FINGERPRINT REGISTRATION
4. Press and release Wake-Up Button (F)
- Place a registered finger on the Fingerprint Scanner (D)
- Bolts will retract
4. CLOSE/OPEN SAFE DOOR
CLOSE: Close door, press and release Wake-Up Button (F)
- Bolts will extend
OPEN: Press and release Wake-Up Button (F)
- Place a registered finger on Fingerprint Scanner (D)
- Bolts will retract
5. BEEP SOUND OPTIONS
Beep OFF: Press and HOLD the Initialization Button (A) until
the Indicator Lights (E) are flashing green – RELEASE the
Initialization Button
Beep ON: Press and HOLD the Initialization Button (A) until
the Indicator Lights (E) are flashing green followed by 1 beep
– RELEASE the Initialization Button
6. DOOR OPEN ALARM
Regardless of the beep sound option chosen (either On or Off)
the door alarm is fixed to beep
The alarm is activated when the safe door is open and Bolts
(C) are retracted
Within 5 seconds, the Indicator Lights (E) will start to
flash green
More than 5 minutes, the safe will start beeping every
10-20 seconds
Close safe door, press and release Wake-Up Button (F) to
extend the Bolts (C) to cease the alarm
With the safe door open and the Bolts (C) extended, no lights
or beeping will be heard
7. OPEN SAFE WITH EMERGENCY KEY
1. To expose the Emergency Key access, remove Logo
Plate (G) screws with provided Allen wrench
2. Insert Emergency Key into key access, and turn clockwise
to open
NOTE: Store Emergency Keys in a secure place, NOT inside
of the safe
C
F. Wake-Up Button
G. Logo Plate and Emergency
Key Access
H. External Battery Access
(optional)
WARNING
- New Safe is in Factory Default mode, ANY fingerprint
can open the safe. Only successful registered
fingerprint can terminate Factory Default mode.
- Register at least two different fingerprints and test a
few times before closing the safe door.
- Test with a non-registered fingerprint. If the safe
opens, the safe remains in Factory Default mode.
- Avoid leaving safe door open and unattended; it will
allow unauthorized individuals to add their fingerprints
and/or reprogram the safe, gaining full access to the
safe and the contents.
- Test the Emergency Keys and store them in a secure
place, NOT inside of the safe.
- To maximize the security and performance of the
safe, test registered fingerprints every 6 months.
Read all instructions before using this safe.
Produktspecifikationer
| Varumärke: | Barska |
| Kategori: | Valv |
| Modell: | AX11224 |
Behöver du hjälp?
Om du behöver hjälp med Barska AX11224 ställ en fråga nedan och andra användare kommer att svara dig
Valv Barska Manualer
13 September 2024
13 September 2024
13 September 2024
13 September 2024
13 September 2024
13 September 2024
13 September 2024
13 September 2024
13 September 2024
13 September 2024
Valv Manualer
- Sistec
- Guzzanti
- Duralock
- Oxloc
- Juwel
- Master Lock
- Steren
- Ferm
- Nedis
- Filex
- First Austria
- FireKing
- Kreator
- SereneLife
- Kreator-Varo
Nyaste Valv Manualer
1 April 2025
1 April 2025
1 April 2025
1 April 2025
1 April 2025
27 Mars 2025
1 Februari 2025
9 Januari 2025
7 Januari 2025
1 Januari 2025