Broan 353 Bruksanvisning


Läs gratis den bruksanvisning för Broan 353 (8 sidor) i kategorin ej kategoriserat. Guiden har ansetts hjälpsam av 3 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 2 recensioner. Har du en fråga om Broan 353 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/8
GABLE-MOUNT
POWERED ATTIC
VENTILATOR
MODEL 353
MODEL 35316
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have
questions, contact the manufacturer at the address or telephone number
listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock
the service disconnecting means to prevent power from being switched
on accidentally. When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done by a qualified person(s)
in accordance with all applicable codes and standards, including fire-rated
construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturers guidelines and
safety standards such as those published by the National Fire Protection
Association (NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
6. The wiring must be permanent. DO NOT USE AN EXTENSION CORD!
Use 14 GA. MINIMUM copper wire. Although the Powered Attic Ventilator
may be wired directly to power, we advise that some type of shut off
switch be installed in the line. Please see the section on electrical wiring
for suggested wiring diagrams and instructions.
7. This unit must be grounded.
7. Records show, under ideal conditions, exposed galvanized steel can
remain rust free up to 100 years. For best protection, the exposed
portion of the roof sheet should be painted, especially in areas of
unusually high industrial air pollution. Follow paint manufacturer’s
instructions for good adhesion.
8. This ventilator is intended for Gable installation. The Broan Models
350, 355, 356 & 358 Roof Mount Ventilators are available for roof
mount applications.
9. Please read specification label on product for further information
and requirements.
10. The wearing of safety glasses and gloves is recommended when
installing, maintaining or cleaning the unit to reduce the risk of injury
that could be caused by the presence of thin metal and/or high
moving parts.
11. If the fan makes excessive noise or if there is unusual noise or smells
of smoke, disconnect power supply and contact customer service.
If this fan is to be used to ventilate a garage:
A. Use only in single family, residential garages
B. Install in a GFCI protected branch circuit
C. To help offset the risk posed by high concentrations of vapors from
paints, glues, solvents, and fuels, install fan at least 18 inches (0.5m)
above the floor
D. NEVER run a vehicle or use a fuel burning appliance inside of a
garage. Deadly levels of carbon monoxide can build up in the area.
Using this garage fan, or opening windows and doors, will NOT
supply enough fresh air to eliminate the danger.
E. Run regularly if exposed to salty air environments
F. Extra cleaning may be required due to possible dirty surroundings
Screwdrivers (Slotted & Phillips)
Hammer
Ruler
Pencil
TOOLS & MATERIALS REQUIRED
PREPARE THE VENTILATOR
1. Unpack the ventilator and find:
1 - power unit with wiring box
4 - angle brackets
8 - sheet metal screws
2. Fasten the four (4) angle
mounting brackets to the housing
using the eight (8) sheet metal
screws provided. Position the
bracket flush with the edge of the
housing band. A close fit between
ventilator and louver will minimize
air recirculation.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or
explosive materials or vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
CAUTION
Electrical supplies
(to comply with codes)
Nails
3. This unit has an unguarded impeller. Do not use in locations readily
accessible to people or animals.
4. Fan is equipped with a thermostat which may start fan automatically.
To reduce risk of injury or electric shock while servicing and cleaning
unit, switch power off at service panel and lock service panel to
prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
5. Home Ventilating Institute (HVI) recommends one square foot of
open air inlet per 300 cfm of fan capacity. The best location for these
air intake vents are under the eaves with direct access to the attic.
Vents for attic side wall installations should be placed at the end of
the house opposite the installed ventilator. Failure to provide these
intakes could cause natural-draft gas appliances to backdraft.
6. Your attic installation will create a screened opening into your attic
space. During a heavy rainstorm there could be a light spray of rain
into this attic space. This is a normal condition with all attic ventilators
and will not cause any damage to the structure.We recommend that
you do not store any valuable articles directly under the fan opening
in the gable. During extreme rain and wind storms you may want to
turn on your attic ventilator to prevent excess mositure accumulaltion
in your attic.
2
INSTALL THE VENTILATOR
1. The ventilator is designed to mount behind existing louvers.
Find the type of louver you have in the examples below. If no
louver exists, one must be installed. Louver should be mounted
in the center of the upper portion of the gable as high as pos-
sible. For maximum efficiency, the area of the louver should
be greater than the outlet area of the ventilator.
There is some loss in fan output because the louver blocks
some of the air flow. Metal louvers have more open area than
wood louvers and usually allow more air flow.
When installing the ventilator behind louvers, you should seal
off any louver area not covered by the ventilator housing band
to prevent air leakage and recirculation. We suggest you mount
the ventilator on a piece of plywood for best sealing. Allow at
least one square foot of air intake area for every 300 CFM of
ventilator capacity.
CAUTION! When installing louvers or shutters, do not re-
move any existing structural members without providing
alternate support members.
The ventilator can be mounted flush to a rectangular type
louver by fastening through the mounting brackets to the
frame of the louver.
On a wide louver the brackets can first be fastened to the
backside of two boards of the appropriate length and these
boards can then be fastened to the frame.
With a narrow louver mounted between studs on 16” centers,
two of the brackets can first be mounted to the backside of
boards and the boards and other brackets nailed to the studs.
The ventilator can also be mounted off-center in an odd
shaped louver.
On large triangular louvers, mount to the frame or nail boards
to the frame to provide a mounting surface for the ventilator.
For the most effective installation, enclose the louver area not
covered by the fan, with plywood or similar material.
Louvers that are smaller than the ventilator outlet will restrict
air delivery. When this condition exists, a chamber should be
built to properly direct the air through the louvers. A typical
example of the suggested construction is shown.
An automatic shutter, Model 433, may also be installed to
provide the necessary outlet for the fan. Installation instruc-
tions are provided with the Model 433 shutter.


Produktspecifikationer

Varumärke: Broan
Kategori: ej kategoriserat
Modell: 353

Behöver du hjälp?

Om du behöver hjälp med Broan 353 ställ en fråga nedan och andra användare kommer att svara dig




ej kategoriserat Broan Manualer

Broan

Broan 353 Bruksanvisning

28 September 2025
Broan

Broan 345SOBK Bruksanvisning

28 September 2025
Broan

Broan 350BR Bruksanvisning

27 September 2025
Broan

Broan 35316 Bruksanvisning

27 September 2025
Broan

Broan 358 Bruksanvisning

27 September 2025
Broan

Broan 356BR Bruksanvisning

27 September 2025
Broan

Broan 345SOWW Bruksanvisning

27 September 2025

ej kategoriserat Manualer

Nyaste ej kategoriserat Manualer