Läs gratis den bruksanvisning för Broan F403601 (8 sidor) i kategorin Fläktkåpa. Guiden har ansetts hjälpsam av 17 personer och har ett genomsnittsbetyg på 3.8 stjärnor baserat på 9 recensioner. Har du en fråga om Broan F403601 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/8
INSTALLATION, USE, AND CARE QUICK START MANUAL
BROAN-NUTONE RANGE HOODS
READ AND SAVE THESE INSTRUCTIONS
⚠ WARNING ⚠ WARNING
CAUTION
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
Use this unit only in the manner intended by the manufacturer. If you have questions,
contact the manufacturer at the address or telephone number listed in the warranty.
Before servicing or cleaning unit, switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
Installation work and electrical wiring must be done by a qualified person(s) in accordance
with all applicable codes and standards, including fire-rated construction.
Sufficient air is needed for proper combustion and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment
manufacturer’s guidelines and safety standards such as those published by the National
Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and the local code authorities.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other
hidden utilities.
Ducted fans must always be vented to the outdoors.
Do not use this unit with any additional solid-state speed control device.
To reduce the risk of fire, use only metal ductwork.
This unit must be grounded.
As an alternative, this product may be installed with the UL-approved cord kit designated
for the product, following instructions packed with the cord kit.
When applicable local regulations comprise more restrictive installation and/or certification
requirements, the aforementioned requirements prevail on those of this document and the
installer agrees to conform to these at his own expense.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause
smoking and greasy spillovers that may ignite. Heat oils slowly on low or
medium settings.
b) Always turn hood ON when cooking at high heat or when flambeing food
(i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fan frequently. Grease should not be allowed to
accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the size of the
surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A
RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray,
then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE
FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE
FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels — This could
cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
For indoor use only.
For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
Your hood motor has a thermal overload which
will automatically shut off the motor if it becomes
overheated. The motor will restart when it cools down.
If the motor continues to shut off and restart, have the
hood serviced.
For best capture of cooking fumes, the bottom of the
hood MUST NOT BE LESS than 18” for electric range
or 26” for gas range and at a recommendedmaximum
of 30” above the cooking surface (at installer
discretion).
Always follow the cooking equipment manufacturer’s
requirements regarding the ventilation needs.
To reduce the risk of fire and to properly exhaust air,
be sure to duct air outside — Do not exhaust air into
spaces within walls or ceiling or into attics, crawl space
or garage.
When installing, servicing or cleaning the unit, it is
recommended to wear safety glasses and gloves.
Please read specification label on product for further
information and requirements.
Always use tools appropriate for the task being
performed.
In the United States In Canada
For complete warranty statement and service parts, or to learn more about
the instructions below, please type your model number in on our website.
Broan-NuTone.com Broan-NuTone.ca
To obtain a paper copy of the detailed instructions, please call us. 800-558-1711 800-567-3855
SOFFIT
18" MIN - 24" MAX
ABOVE
COOKING SURFACE
CABINET
3¼" X 10" DUCT
(F
OR
HORIZONTAL
DISCHARGE
)
W
ALL
CAP
ROOF CAP
3¼" X 10", 6" ROUND OR
7" ROUND DUCT
(FOR VERTICAL
DISCHARGE
)
HOUSE WIRING
(TOP OR BACK OF HOOD)
HOOD
HH0327A
1114025A
EN
electrical range - 18" min
gas range - 26" min
above cooking surface
NOTE: Mounting distances over 30" are at the installer and user
discretion.
HM0023
3¼" x 10" damper/
duct connector*/**
*some models only
**save screws
7” round damper
(bueZ2 series only)
ductfree filter*
aluminum filter*
7” round duct plate
(f40000 series only)** (not shown)
parts bag
B INSTALL DUCTWORK (DUCTED INSTALLATIONS) C CHECK BOX CONTENT
HO0434
TOP
REAR
D PREPARE THE HOOD
HM0023
OR
HD1089
HINGE PINS
B C
NON-DUCTED INSTALLATION ONLY
D E
OR
install a strain relief
RECOMMENDED TOOLS AND ACCESSORIES
1/8” & 7/64”
1-1/2”
Wood shims (2) and wood screws (4)
Strain relief, 1/2” diameter
BP87Q Damper (7” round ducting)
E PERFORM REQUIRED CUTOUTS
Use the proper diagram below for placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole, only cut the hole for electrical wiring.
DUCT ACCESS HOLE
AA
CENTER LINE
ELECTRICAL ACCESS
( )
WOOD SHIMS
(-  )
CABINET FRONT
1¹/"
2¹/"
7¹/"
5¹/"
CABINET
BOTTOM
CABINET FRONT
CABINET
BOTTOM
7" DUCT
ACCESS HOLE
For 3¼” x 10adapter/damper, A = 5¼”
5¹/ or 5⁷/"
8" Ø
2¹/"
7¹/"
CENTER LINE
ELECTRICAL ACCESS
( )
WOOD SHIMS
(-  )
HD1576A
VERTICAL DISCHARGE
For 3¼” x 10adapter/damper, A = 5¼”
4"
³/"
A
7¹/"
CENTER LINE
A
CABINET FRONT
FLUSH
DUCT ACCESS HOLE
CABINET
BOTTOM
ELECTRICAL ACCESS
( )
HD1577A
WOOD SHIMS
(-  )
HORIZONTAL DISCHARGE
Remove electrical access panel. Remove louver cover from front of hood. Remove either top or rear electrical knockout.
DUCTED INSTALLATION ONLY
Remove appropriate duct knockout.
Fit damper/duct connector over opening.
Hinge pins per figure above.


Produktspecifikationer

Varumärke: Broan
Kategori: Fläktkåpa
Modell: F403601

Behöver du hjälp?

Om du behöver hjälp med Broan F403601 ställ en fråga nedan och andra användare kommer att svara dig