Burg-Wachter PointSafe P 4 E FS Bruksanvisning
Burg-Wachter
Valv
PointSafe P 4 E FS
Läs gratis den bruksanvisning för Burg-Wachter PointSafe P 4 E FS (8 sidor) i kategorin Valv. Guiden har ansetts hjälpsam av 36 personer och har ett genomsnittsbetyg på 4.9 stjärnor baserat på 18.5 recensioner. Har du en fråga om Burg-Wachter PointSafe P 4 E FS eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/8

www.burg.biz
BURG-WÄCHTER KG
Altenhofer Weg 15
58300 Wetter
Germany
PointSafe FS
en User Manual
BA PointSafe FS dp 02/2015


PointSafe FS English 2 |
Structure Dear customer,
Thank you for buying a PointSafe FP. This safe was developed and manu-
factured by Burg-Wächter using the latest fingerprint sensor technology.
This Fingerprint (FP) PointSafe has been designed to be used in both
standard and hotel modes. In addition to the keypad and Fingerprint reader,
this safe comes with mechanical emergency override key.
Important: Please read the entire User Manual before
you start programming.
We hope you enjoy your new Fingerprint safe.BURG-WÄCHTER
Important Notes
– Store your codes and emergency Override key at a secure location
and Not inside the safe (the emergency lock is located under
the 4 batteries).
– For security reasons we recommend you do use personal numbers Not
for example D. O. B and Telephone numbers as your User or Master code.
– If the safe is not going to be used for a prolonged period of time,
please remove the batteries.
– For hotel mode: See “ ” and the attachedPointSafe FP in hotel mode
guest code instructions.
– For security reasons, Both the user and administrator codes should
be changed from there factory settings.
– This Fingerprint Pointsafe will only reach its required security level
if correctly bolt fixed to a secure wall or floor.
(Please use the provided anchoring bolts)
– For security reasons, the user code should be different from
the Master code.
– Please contact your vendor if you have any questions or problems
regarding your PointSafe FS.
General
This PointSafe FP can be operated in both standard mode and hotel mode.
Standard mode: The safe can be operated by using a Master code,
User code and up to fingerprints.5
Hotel mode: The safe can be operated by using a Master code,
User code and fingerprint.1
The Master code must have 8 digits.
The user code can have between 3 and 6 digits.
Master Code: 12345678 (factory set)
User Code: 168 (factory set)
When an action has been successfully completed, the green “opening
readiness” LED goes on. The red “Denied entry / Blocking time” LED indicates
that the action failed. In such case the original settings are retained.
Illustrations
Close / Clear button
Control of the locking mechanism for automated closing of the bolts.
On / Enter button
Green “Ready” LED
When a valid opening code is entered and programming is successful,
the LED goes on.
Battery replacement symbol
When this LED is on, please replace batteriesall 4
(LR6 / AA / 1.5V / Alkaline).
Entry / Programming LED
When PointSafe is in programming mode, the LED goes on.
When the programming mode is terminated LED goes out.
Denied entry / Blocking time
The LED is on when an invalid code is entered or programming is
incorrect. When a incorrect code is entered three times in a row,
the operation of the safe will be blocked for 5 minutes. The LED will
flash during this time and code entry or fingerprint will not work
during this time.
Technical Data
Blocking times After 3 wrong code entries for 5 minutes
Power supply 4 x MIGNON LR6 / AA / ALKALINE
Working
temperature
conditions
-15 °C to + 50 °C
up to 95 % rel. air humidity (noncondensing)
Signal Tones
1 x During opening or closing
2 x Fingerprint sensor defective or a contact problem
3 x No guest code stored in hotel mode
8 x Motor or bolt mechanism blocked
Setting up PointSafe
– Remove the screw from the battery compartment side
– Shift the front panel cover cap with the PointSafe logo down
– Insert the batteries (4 pieces, LR6 / AA / 1.5V / Alkaline)
– The electronics will need approx. 30 sec. to load the program.
Then press the “Enter” button
– Enter the user code (168)
– Press the “Enter” button again
Now the safe can be opened and individually programmed
Standard Mode
Opening with Master code
– Press “On / Enter”, then enter the Master code.
The door automatically opens.
Opening with User code
– Press “On / Enter”, then enter the User code.
The door automatically opens.
Open with finger
– Press “On / Enter”, then move your stored finger over the sensor.
The door automatically opens.
Close
– Press the “Close / Clear” button.
Produktspecifikationer
Varumärke: | Burg-Wachter |
Kategori: | Valv |
Modell: | PointSafe P 4 E FS |
Behöver du hjälp?
Om du behöver hjälp med Burg-Wachter PointSafe P 4 E FS ställ en fråga nedan och andra användare kommer att svara dig
Valv Burg-Wachter Manualer
27 Mars 2025
31 December 2025
31 December 2025
6 December 2024
6 December 2024
6 December 2024
30 September 2024
29 September 2024
14 September 2024
8 September 2024
Valv Manualer
- ROMA
- Barska
- Kreator
- Sygonix
- Juwel
- Yale
- Hama
- EasySafe
- Royal Sovereign
- Challenge
- Dometic
- Honeywell
- Rottner
- Handson