Camille Bauer Sineax V608 Bruksanvisning


Läs gratis den bruksanvisning för Camille Bauer Sineax V608 (4 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 16 personer och har ett genomsnittsbetyg på 4.9 stjärnor baserat på 8.5 recensioner. Har du en fråga om Camille Bauer Sineax V608 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/4
1
Contents
1. Read first and then … ..........................................................................1
2. Scope of supply ....................................................................................
1
3. Brief description ....................................................................................
1
4. Technical data .......................................................................................
1
5. Mounting ...............................................................................................
2
6. Electrical connections ...........................................................................
2
7. Configuring the transmitter ...................................................................
3
8. Commissioning .....................................................................................
4
9. Maintenance .........................................................................................
4
10. Accessories and spare parts ................................................................
4
11. Releasing the transmitter ......................................................................
4
12. Dimensional drawings ...........................................................................
4
13. Declaration of conformity ......................................................................
4
1. Read first and then …
The proper and safe operation of the device assumes that the
Operating Instructions are read and the safety warnings given
in the various Sections
5. Mounting
6. Electrical connections
7. Configuring the transmitter
8. Commissioning
are
observed.
The device should only be handled by appropriately trained personnel who
are familiar with it and authorised to work in electrical installations.
Unauthorized repair or alteration of the unit invalidates the warranty.
2. Scope of supply (Figs. 1 and 2)
Transmitter (1)
Order Code: Significance of the 2nd. and 3rd. digits
Description Order Code
2. Version 608 - 8
Standard,
not electrically isolated 1
EEx ia IIC T6, not electrically isolated 3
3.
Configuration
Basic configuration, programmed 0
Configured to order
1
Fig. 1 Fig. 2
1 Operating Instructions (2) in German, French and English
1 Type Examination Certificate (3), only for “intrinsically safe” explosion-
proof devices)
Programmable
Temperature
Transmitter
SINEAX V 608
V 608-8 Be 142 117-01 02.06
Camille Bauer LTD
Aargauerstrasse 7
CH-5610 Wohlen/Switzerland
Phone +41 56 618 21 11
Fax +41 56 618 35 35
e-mail: info@camillebauer.com
http://www.camillebauer.com
Operating Instructions
The instruments must only be disposed of in the
correct way!
Safety precautions to be strictly observed are marked with following
symbols in the Operating Instructions:
3. Brief description
The programmable SINEAX V 608 is a two-wire transmitter.
It is used for measuring temperature in conjunction with a thermocouple
or resistance thermometer. Thermocouple non-linearities are automatically
compensated. The output signal is a current in the range 4…20 mA.
Measured variable, measuring range, signalling and other parameters are
programmed with the aid of a PC and the corresponding software.
The sensor circuit is monitored for open and short-circuits and the output
responds in a defined manner if one is detected.
The power supply of 12…30 V DC is connected together with the signal by
the two leads connected to the measurement output (loop powered).
Explosion-proof “intrinsically safe” EEx ia IIC T6 versions rounds off the
series of transmitters.
Transmitters supplied as standard versions are configured as follows:
– Measuring input:
– Measuring range:
– Measuring output:
– Open-circuit supervision:
– Mains ripple suppression:
Pt 100 for three-wire connection
0 … 600 °C
4 … 20 mA
Output 21.6 mA
For frequency 50 Hz
4. Technical data
Measuring input
Input variable and measuring range configured
Input variables
Measuring ranges
Limits
Min.
span
Max.
span
Temperatures with
resistance thermometers
for two, three or
four-wire connection
Pt 100, IEC 60 751 – 200 to 850 °C 50 K 850 K
Ni 100, DIN 43 760 – 60 to 250 °C 50 K 250 K
Temperatures with
thermocouples
Type B, E, J, K, N, R, S, T
acc. to IEC 60 584-1
Type L and U, DIN 43 710
Type W5 Re/W26 Re,
Type W3 Re/W25 Re
acc. to ASTM E 988-90
acc. to type 2 mV 80 mV
Cold junction compensation
Internal: Incorporated Pt 100
or
with Pt 100 connected to the terminals
External: Via cold junction thermostat
0 … 60 °C, configurable
(1)
(2)
(3)


Produktspecifikationer

Varumärke: Camille Bauer
Kategori: Inte kategoriserad
Modell: Sineax V608

Behöver du hjälp?

Om du behöver hjälp med Camille Bauer Sineax V608 ställ en fråga nedan och andra användare kommer att svara dig