Läs gratis den bruksanvisning för Cocraft DL-04 (4 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 22 personer och har ett genomsnittsbetyg på 3.9 stjärnor baserat på 11.5 recensioner. Har du en fråga om Cocraft DL-04 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/4
GREAT BRITAIN
For consumer contact, please visit www.clasohlson.co.uk
and click on customer service.
Digital Spirit Level
Art. No 40-8180 Model DL-04 (D600XP)
Please read theentire instruction manual before use and save it for future
reference. Wereserve theright for any errors in text or images and for making any
necessary technical changes to this document. Ifyou should have any questions
concerning technical problems please contact our Customer Services.
Safety
Always keep thespirit level out of thereach of children and animals.
Remove exhausted batteries.
Do not incinerate exhausted batteries.
Do not short-circuit thebatteries.
Do not mix old and new batteries.
Make sure that thebatteries are inserted as indicated by themarkings in
thebattery compartment.
Care and maintenance
The spirit level is aprecision instrument and must be handled with care.
Do not expose thespirit level to dust and moisture. The spirit level must not
be subjected to blows, vibration and extreme temperatures. If thespirit level
is to be unused for along time, remove thebatteries.
Disposal
Follow local ordinances when disposing of this product. If you are unsure
about how to dispose of this product contact local council.
Description
600 mm digital spirit level.
Sturdy aluminium frame.
Two bubble vials for level and plumb, high precision, deviation only ± 0.5 mm/m.
Digital slope measurement, accuracy ± 0.2°. Resultcan be displayed in °,
%, mm/m or in/ft.
V-shaped groove along theentire underside allows precision measurement
on pipes as well.
If you choose theunits in/ft, thedisplay
shows H = 6 7/8 (H=L·tan α, L = 3.28 ft,
α = 30°). If you choose slope in %,
thedisplay shows H = 57.72 (H=L·tan , α
L = 100, α = 30°).
Buttons
1. [CAL] Press to enter calibration mode.
2. [UNIT] ] Press to toggle between different display units: ° (degrees),
% (slope), mm/m and in/ft (rising - falling).
3. [Hold] Press to save thecurrently displayed data. Whenthe hold function
has been activated, thedisplay shows H”. Press[Hold] again to deac-
tivate thefunction.
4. [REF] Press to save areference point. Whenthe reference point has been
saved, thedisplay shows S”. Press[REF] again to deactivate it.
5. [Audio] Switch buzzer on/off. Whenthe buzzer is on, it sounds at 0°, 45°
and 9 (± 0.5°).
6. [ ] Press to switch on thespirit level. Holddown for about three seconds
to switch off thespirit level.
Display icons
7. Showsgraphically whether thelevel is sloping up or down or is level.
8. Showsthat thebuzzer is active
9. Hshows that thehold function has been activated (display data frozen)
10. Sshows that areference point has been saved
11. Showsthe slope
12. Batterystatus
Examples of different displays for thesame slope. Press[UNIT] to change
thedisplay units.
Measuredslope is
displayed in
degrees: 30°
Measuredslope
is displayed as
apercentage:
57,72 %
Measuredslope is
displayed in
millimetres/metre:
577 mm/m
Measuredslope
is displayed in
inches per foot:
6 7/8 in/ft
Ifthe angle is greater than 45° but less
than 90° (H=L/tan ).α
NOTE: The display switches off automatically when thebatteries are low.
Tosave thebatteries there is an automatic switch-off function which switches
off thespirit level if it has been motionless for three minutes.
Use
1. Press [ ]; thedisplay comes on.
2. Placethe spirit level on alevel surface. Theslope is displayed directly as 090°.
3. Theangle is displayed in both directions.
Measurement from a reference surface
During measurement you can save ameasured
value as 0° so that it can be used as areference
for thenext measurement.
Example: You want to use theslope (A) as
areference for thenext measurement (B).
1. Place thespirit level on thereference surface (A).
2. Press [REF]. Thedisplay shows 0”.
3. Place thespirit level on thenew measurement
surface (B).
4. Read off theangle between (A) and (B) on
thedisplay.
Calibrating the spirit level
1. Placethe spirit level on aat surface with aslope of less than 5°.
Ifthe slope is greater, thedisplay shows “Err”.
2. Holddown [CAL] for about ve seconds to start calibration.
3. Whenthe display shows “CAL 1”, release thebutton and wait for
theactual slope to be displayed.
4. Turnthe spirit level through 18 and put it back on thesame surface.
5. Holddown [CAL] for about ve seconds and release thebutton when
“CAL 2” appears.
6. “CAL 2” ashes three times and thereading is displayed again.
Technical specification
Length 600 mm
Accuracy, digital slope gauge ± 0.2°
Accuracy of bubble vials ± 0.5 mm/m
Measuring range 0 to 90°
Units of measurement °, %, mm/m, in/ft
Environment for use 0 °C to 40 °C
1
3
9
8 10 12
52
711
4
6
H=L·tan α
H=L/tan α
45°< < 90°α