CyberPower BP240VL3U01 Bruksanvisning
                    CyberPower
                    
                    Inte kategoriserad
                    
                    BP240VL3U01
                
                                
    Läs gratis den bruksanvisning för CyberPower BP240VL3U01 (1 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 9 personer och har ett genomsnittsbetyg på 4.7 stjärnor baserat på 5 recensioner. Har du en fråga om CyberPower BP240VL3U01 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
                        Sida 1/1
                    
                    
                    
1
2
3
4
5
6
7
8
9
2U
3U
4U
1U
1.  Switch EBM DC breaker to the ON position.
2.  Switch the utility circuit breaker feeding the UPS  
to the ON position.
3.  Turn the UPS ON – push and hold the ON/OFF 
power button for 3 seconds; you will hear 
continuous beeps, the BATTERY ON yellow  
LED will first turn on for a couple of seconds 
followed by the ON-LINE green LED.
4.  Customize UPS system configuration settings as 
needed. See User’s Manual for complete details.  
User Manual is available to download on  
www.CyberPowerSystems.com.
5.  Connect equipment load to the UPS system.
1.  Install rack mount ears to the extended battery 
module (EBM) using eight black M5X7L flat head 
screws. Install hanging brackets using six silver 
M5X6L pan head screws. 
2.  Locate the space where the extended battery 
module will be installed in the rack.
3.  Install the rackmount rails using eight black 
M5X12L pan head screws with plastic washers 
and adjust the rails to the necessary rack depth.
4.  Place the extended battery module on to the 
rackmount rails. Make sure both left and right 
hanging brackets are securely on the rackmount 
rails. Secure the extended battery module with 
the rack mount ears to the rack using four black 
M5X12L pan head screws.
BP240VL3U01/ BP240VL3U02
QUICK START GUIDE
K01-0000704-00
UNPACKING
RACKMOUNT INSTALLATION
TOWER INSTALLATION
CONNECTING UPS TO  
EXTENDED BATTERY MODULE
CONNECTING UPS TO MULTIPLE
EXTENDED BATTERY MODULES
EXTERNAL BATTERY MODULE CONFIGURATION
POWER ON THE UPS SYSTEM
1.  Turn o the DC breaker on the EBM.
2.  Loosen the two screws to remove the battery 
cable retention bracket of the power module.
3.  Use the output cable of the EBM to connect it  
to the power module.
4.  Rotate the battery cable retention bracket  
and tighten the two screws to secure the  
battery connector.
5.  Turn on the DC breaker on the EBM.
1.  Connect the 1st EBM to the UPS power module 
following the “Connecting UPS to Extended Bat-
tery Module” instructions.
2.  Turn o the DC breaker of the 2nd EBM.
3.  Loosen the two screws to remove the battery 
cable retention bracket of the 1st EBM.
4.  Use the output cable of the 2nd EBM to con-
nect it to the 1st EBM. Rotate the battery cable 
retention bracket and tighten the two screws to 
secure the battery connector.
5.  Turn on the DC breaker on the 2nd EBM.
6.  Proceed to the External Battery Module  
Configuration instructions to set the EBM  
Number to the quantity of additional units  
installed with the UPS system. This operation 
can also be done if there is an RMCARD  
installed in the UPS, or via PowerPanel®  
Business Edition Agent software. Please see 
their respective User’s Manuals for instructions.
1.  Adhere four circular rubber pads to the left hand 
side of the extended battery module. This will 
become the bottom side.
2.  Stand the extended battery module on its 
side with the rubber pads facing down. Install 
dust covers on open screw holes. If installing 
the extended battery module together with a 
UPS or an additional EBM secure the tie plate 
between the two using four black M5X7L flat 
head screws. Optionally adhere four circular 
rubber pads to each rack mount ear to use as 
tower stands. Screw the tower stands on to the 
EBM and UPS using four black M5X12L pan head 
screws for added stability as shown below.  
1
3 41 Rack mount ear
Rack mount rail
2
This document is believed to be accurate, but CyberPower reserves the right to change or correct the contents and does not 
assume any responsibility for omissions or errors. Entire contents copyright ©2018 CyberPower Systems, Inc. All rights reserved. 
Reproduction in whole or in part without permission is prohibited. 
Need Additional Help? Feel free to contact our Tech Support department with installation, troubleshooting, 
or general product questions.
CyberPower Technical Support | 1-877-297-6937 | tech@cpsww.com | www.CyberPowerSystems.com
Mailing Address: 4241 12th Avenue E, Suite 400, Shakopee, MN 55379, USA
Hours of Operation: Monday–Friday, 7:00am–6:00pm (CST)
IEC320 C14 TO IEC320 C13 
POWER CORD RT GUIDE  x1
LEFT & RIGHT RACKMOUNT 
RAILS x1 EACH
LEFT & RIGHT HANGING 
BRACKETS x1 EACH
3U RACKMOUNT EARS 
(TOWER STANDS) x2
TOWER INSTALLATION  
TIE PLATE x1
M5X7L BLACK FLAT 
HEAD SCREWS x8
M5X12L BLACK PAN  
HEAD SCREWS x12
QUICK START GUIDE  x1REGISTRATION CARD  x2EXTENDED BATTERY 
MODULE (EBM) x1
M5X6L SILVER PAN 
HEAD SCREWS x6
PLASTIC WASHERS x8SCREW HOLE DUST 
COVERS x14
RUBBER PADS x12
CAUTION! Installation environment should be in a temperature and humidity controlled indoor area free of conductive 
  contaminants. Do not install this EBM where excessive moisture or heat is present (Please see specifications for acceptable 
  temperature and humidity range).
CAUTION! Never install an EBM, or associated wiring or equipment, during a lightning storm.
CAUTION! Do not work alone under hazardous conditions.
CAUTION! Risk of electric shock, do not remove top cover.
CAUTION! The battery can energize hazardous live parts inside even when the AC input power is disconnected.
CAUTION! Only use replacement batteries which are certified by Cyber Power Systems. Use of incorrect battery type is an electrical 
  hazard that could lead to explosion, fire, electric shock, or short circuit. 
CAUTION! Batteries contain an electrical charge that can cause severe burns. Before servicing batteries, please remove any 
  conductive materials such as jewelry, chains, wrist watches, and rings.
CAUTION! Do not open or mutilate the batteries. Electrolyte fluid is harmful to the skin/eyes and may be toxic.
CAUTION! To avoid electric shock, turn o and unplug the EBM from the wall receptacle (if installed) before servicing the battery.
CAUTION! Only use tools with insulated handles. Do not lay tools or metal parts on top of the UPS or battery terminals.
CAUTION! To prevent the risk of fire or electric shock, only use the supplied hardware to attach the mounting brackets.
1
OFF
External Battery Modules can be configured by the 
user to display correct estimated battery runtimes.
1.  Press the “ ” button to activate the  ENTER
“MAIN MENU.”
2.  Press the “p” and “ ” buttons to scroll to the q
“Configure” menu.
3.  Press the “ENTER” button to select the  
“Configure” menu.
4.  Press the “p” and “ ” buttons to scroll to the q
“EBM Number” option.
5.  Press the “ ” button to select the  ENTER
“EBM Number” option. 
The first configuration number will be displayed 
on the second column of LCD display.
6.  Press the “p” and “ ” buttons to scroll through q
the number of attached Battery modules. 
NOTE: The first EBM is recognized by the UPS 
system as number zero “0”. Set the EBM Number 
to the quantity of additional units installed with 
the UPS system. 
7.  Press the “ ” button to select the number ENTER
of EBM installed. 
You will be prompted to save the selection.  
Press the “ENTER” button to save.
8.  Press the “ ” button to cancel or return  ESC
to the previous LCD menu.
IMPORTANT SAFETY INSTRUCTIONS
This Quick Start Guide contains important instructions. Please read and follow all instructions carefully 
during the installation and operation of the unit. Read this Quick Start Guide thoroughly before 
attempting to unpack, install, or operate this unit.
PLUG INTO A 
WALL 
RECEPTACLE
RELA Y
OUT PUT
OUT
IN
USB
RS23 2
BACK -FEED  PROT ECTI ON
CON NECT OR
BATT ERY  INPU T :  240V
EPO
IN TERF ACE
FU SE
250V~
10A
AC  INPU T
(Cha rge Only )
AC  OUTP UT
240V 
BATT ERY  OUTPU T
BATT ERY  INPU T
240V 
1
OUT PUT  BREAKE R
30A/250V~
OUT PUT  BREAKE R
30A/250V~
NON CRI TICA L
LOAD
21
CR ITIC AL LOA D43
IN PUT  BREAKER
63A /  250V~
2
CONFIGURE SUBMENU AVAILABLE SETTINGS DEFAULT SETTINGS
EBM Number
= [0] [1] [2] [3] [4] [5] [6] [7] [8] [9] [10]
Sets the quantity of  EBM (extended  
battery modules) number to get the  
correct estimated runtime.
0
42
  
3
ON
1 2
2
OFF
43
Produktspecifikationer
| Varumärke: | CyberPower | 
| Kategori: | Inte kategoriserad | 
| Modell: | BP240VL3U01 | 
Behöver du hjälp?
Om du behöver hjälp med CyberPower BP240VL3U01 ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad CyberPower Manualer
                        
                         3 April 2025
                        
                    
                                                            
                        
                         8 Januari 2025
                        
                    
                                                            
                        
                         8 Januari 2025
                        
                    
                                                            
                        
                         8 Januari 2025
                        
                    
                                                            
                        
                         4 Januari 2025
                        
                    
                                                            
                        
                         4 Januari 2025
                        
                    
                                                            
                        
                         24 December 2024
                        
                    
                                                            
                        
                         12 Oktober 2024
                        
                    
                                                            
                        
                         10 Oktober 2024
                        
                    
                                                            
                        
                         10 Oktober 2024
                        
                    
                                                            Inte kategoriserad Manualer
- Klark Teknik
- Fun Generation
- XGIMI
- Ergotec
- Tornado
- Bayco
- Ultimate Speed
- IOttie
- Liftmaster
- Pattfield
- Overade
- Mammut
- Navitel
- Livington
- Galanz
Nyaste Inte kategoriserad Manualer
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025