Läs gratis den bruksanvisning för Daizuki CXN1848-WN1 (37 sidor) i kategorin Luftkonditionering. Guiden har ansetts hjälpsam av 3 personer och har ett genomsnittsbetyg på 3.5 stjärnor baserat på 2 recensioner. Har du en fråga om Daizuki CXN1848-WN1 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/37
1
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT — This document is customer property and is to remain with this unit. Please return to service information
pack upon completion of work.
These instructions do not cover all variations in systems or provide for every possible contingency to be met in connection with the in-
stallation. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s
purposes, the matter should be referred to your installing dealer or local distributor.
Note : The manufacturer recommends installing only approved matched indoor and outdoor systems. All of the manufac-
turer’s split systems are A.H.R.I. rated only with TXV indoor systems.And the indoor units must be matched with TXV Some
of the benefits of installing approved matched indoor and outdoor split systems are maximum efficiency, optimum
performance and the best overall system reliability.
Condensing Units
Installer’s Guide
Air conditioning & Heating
X DRIVE SERIES
Split System Heat Pump & Air Conditioner
Up to 18 SEER
2-5 Tons
R410A
Table of Contents
Section 1. Safety............................................................................2
Section 2. Unit Location Considerations.....................................3
Section 3. Unit Preparation...........................................................5
Section 4. Setting the Unit............................................................5
Section 5. Refrigerant Line Considerations................................6
Section 6. Refrigerant Line Routing.............................................7
Section 7. Refrigerant Line Brazing.............................................8
Section 8. Refrigerant Line Leak Check....................................10
Section 9. Evacuation..................................................................11
Section 10. Service Valves..........................................................11
Section 11. Electrical - Low Voltage...........................................12
Section 12. Electrical - High Voltage..........................................14
Section 13. Start Up.....................................................................15
Section 14. System Charge Adjustment....................................16
Section 15. System operation and Troubleshooting.................20
NOTE: Appearance of unit may vary.
2
Section 1. Safety
Important - This document contains a wiring diagram
and service information. This is customer property and is
to remain with this unit. Please return to service
information pack upon completion of work.
Failure to follow this warning could result in property
damage, severe personal injury, or death.
Disconnect all electric power, Including remote disconnects
before servicing. Follow proper lockout/tagout procedures
to ensure the power cannot be inadvertently energized.
HAZARDOUS VOLTAGE!
Any attempt to repair a central air conditioning product
may result in property damage, severe personal injury,
or death.
These units use R-410A refrigerant which operates at
50 to 7o% higher pressures than R-22. Use only
R-410A approved service equipment. Refrigerant cylin-
ders are painted a “Rose” color to indicate the type of
refrigerant and may contain a “dip” tube to allow for
charging of liquid refrigerant into the system. The R410
system of 2/3 tons with MITSUBISHI variable compres-
sor uses PVE oil ( FV50S or equal ), and the R410
system of 4/5 tons with GMCC variable compressor
uses POE oil ( VG74 or equal ). Both of them readily
absorb moisture from the atmosphere.To limit this
‘hygroscopic“ action, the system should remain sealed
whenever possible. If a system has been opened to the
atmosphere for more than 4 hours, the compressor oil
must be replaced. Never break a vacuum with air and
always change the driers when opening the system for
component replacement.
May cause minor to severe burning. Failure to follow
this caution could result in property damage or
personal injury. Do not touch top of compressor.
REFRIGERANT OIL!
HOT SURFACE!
Failure to follow proper procedures can result in
personal illness or injury or severe equipment damage.
System contains oil and refrigerant under high pres-
sure. Recover refrigerant to relieve pressure before
opening system.
CONTAINS REFRIGERANT!
Failure to inspect or use proper service tools may
result in equipment damage or personal injury.
Reconnect all grounding devices. All parts of this
product that are capable of conducting electrical
current are grounded. if grounding wires, screws,
straps, clips, nuts, or washers used to complete a
path to ground are removed for service, they must be
returned to their original position and properly
fastened.
GROUNDING REQUIRED!
Failure to follow this warning will result in abrupt
release of system charge and may result in personal
injury and/or property damage. Extreme caution
should be exercised when opening the Liquid Line
Service valve. Turn valve stem counterclockwise only
until the stem contacts the rolled edge. No torque is
required.
SERVICE VALVES!
Failure to inspect lines or use proper service tools
may result in equipment damage or personal injury.
if using existing refrigerant lines make certain that all
joints are brazed, not soldered.
BRAZING REQUIRED!
Failure to follow this warning could result in property
damage, severe personal injury, or death.
Earth connection essential before connecting electri-
cal supply.
HIGH CURRENT LEAKAGE !
WARNING
CAUTION
CAUTION
WARNING
WARNING
WARNING
CAUTION
This information is intended for use by individuals
possessing adequate backgrounds of electrical and
mechanical experience. Any attempt to repair a central air
conditioning product may result in personal injury and/or
property damage. The manufacturer or seller cannot be
responsible for the interpretation of this information, nor
can it assume any liability in connection with its use.
CAUTION
WARNING
The indoor unit must be matched with TXV.And the
model of TXV can be charged according to the
system capacity
INDOOR UNIT REQUIRED!