Danby DAS120GBHWDB Bruksanvisning

Danby Inte kategoriserad DAS120GBHWDB

Läs nedan 📖 manual på svenska för Danby DAS120GBHWDB (76 sidor) i kategorin Inte kategoriserad. Denna guide var användbar för 4 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/76
DANBY PRODUCTS LIMITED, ONTARIO, CANADA N1H 6Z9
DANBY PRODUCTS INC., FINDLAY, OHIO, USA 45840
www.Danby.com
*
*
INSTALLATION MANUAL
MANUEL D'INSTALLATION
MANUAL DE INSTALACIÓN
2020.12.16
FOR ANY QUESTIONS OR CONCERNS REGARDING INSTALLATION OR SERVICING OF THIS UNIT,
PLEASE CONTACT THE DEALER OR BUILDER WHO SOLD THE UNIT.
_____________________________________________________________________
POUR TOUTE QUESTION OU PRÉOCCUPATION CONCERNANT L’INSTALLATION OU L’ENTRETIEN
DE CET APPAREIL, VEUILLEZ CONTACTER LE REVENDEUR OU LE CONSTRUCTEUR QUI A VENDU
L’APPAREIL.
__________________________________________________________________
PARA CUALQUIER PREGUNTA O INQUIETUD RELACIONADA CON LA INSTALACIÓN O SERVICIO DE
ESTA UNIDAD, PÓNGASE EN CONTACTO CON EL DISTRIBUIDOR O CONSTRUCTOR QUE VENDIÓ LA
UNIDAD.
SPLIT AIR CONDITIONER
Installation Guide ............................................... 1 - 26
CLIMATISEUR DIVISÉ
Guide d’installation........................................... 27 - 52
AIRE ACONDICIONADO DIVIDIDO
Guía de instalación............................................ 53 - 78
MODEL MODÈLE MODELO• •
DAS120GBHWDB
DAS170GBHWDB
DAS220GBHWDB
1
SAVE THESE INSTRUCTIONS!
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
SAFETY PRECAUTIONS
Incorrect installation due to ignoring instructions
can cause serious damage or injury.
When connecting refrigerant piping, do not let
substances or gases other than the specifi ed
refrigerant enter the lines as this will lower the
unit’s capacity and can cause abnormally high
pressure in the refrigeration system, which can
lead to explosion or injury.
Installation must be performed by a certifi ed
HVAC technician. Defective installation can
cause water leakage, electrical shock or fi re.
In North America, installation must be
performed in accordance with the requirement
of NEC and CEC by authorized personnel only.
Contact an HVAC technician or the sales agent
for information on repair or maintenance of this
appliance.
Only use the included accessories, parts and
specifi ed parts for installation. Using non-
standard parts can cause water leakage,
electrical shock, fi re and can cause the unit to
fail.
Install the appliance in a fi rm location that can
support the unit’s weight. If the chosen location
cannot support the appliance’s weight, or if
the installation is not completed properly, the
appliance may fall and cause serious injury or
damage.
For all electrical work, follow all local and
national wiring standards and regulations and
this manual. You must use an independent
circuit and single outlet to supply power. Do not
connect other appliances to the same outlet.
Insuffi cient electrical capacity or defects in
electrical work can cause electrical shock or fi re.
For all electrical work, use all specifi ed cables.
Connect cables tightly and clamp them securely
to prevent external forces from damaging the
terminal. Improper electrical connections can
overheat and cause electrical shock or fi re.
All wiring must be correctly arranged to ensure
that the control board can close properly. If the
control board cover is not closed properly, it
can lead to corrosion and cause the connection
points on the terminal to overheat, catch fi re or
cause electrical shock.
In certain functional environments, such as
kitchens, server rooms, etc., the use of specially
designed air conditioning units is highly
recommended.
This appliance is not intended for use by persons
(including children) whose physical, sensory or
metal capabilities may be different or reduced,
or who lack experience or knowledge, unless
such persons receive supervision or training to
operate the appliance by a person responsible
for their safety.
Do not install the appliance in a location that
may be exposed to combustible gas leaks.
If combustible gas accumulates around the
appliance, it may cause fi re.
Do not operate this appliance in a wet room
such as a bathroom or laundry room. Too
much exposure to water can cause electrical
components to short circuit.
The appliance must be properly grounded or
electric shock can occur.
Install drainage piping according to the
instructions in this manual. Improper drainage
may cause water damage.
NOTE ABOUT FLUORINATED GASES
This appliance contains fl uorinated gasses. For
specifi c information on the type and amount of
gas, refer to the relevant label on the appliance
itself.
Installation, service, maintenance and repair of
this appliance must be performed by a certi ed
HVAC technician.
Uninstallation and recycling must be performed
by a certifi ed HVAC technician.
If the appliance has a leak detection system
installed, it must be checked for leaks at least
every 12 months. When the appliance is
checked for leaks, proper record keeping of all
checks is strongly recommended.
2
INSTALLATION INSTRUCTIONS
ACCESSORIES
1. Mounting plate (x2)
2. Mounting plate fi xing screw ST3.9 x 25 (x10)
3. Clip anchor (x10)
4. Remote control (x2)
5. Dry battery AAA.LR03 (x4)
6. Drain joint
7. Tie
8. Putty
9. Wear protective ring wall
10. Power line
11. Drain pipe
12. Connecting pipe
13. Remote control stand
INSTALLATION SUMMARY
Front Panel
Louver
Drainage Pipe
Signal Cable
Refrigerant Pipe
Remote Control
Outdoor Unit
Power Cable
Functional Filter
On Front of Main Filter
Wall Mounting Plate

Produktspecifikationer

Varumärke: Danby
Kategori: Inte kategoriserad
Modell: DAS120GBHWDB
Färg på produkten: Zwart
Förpackningens vikt: 5300 g
Förpackningens bredd: 687 mm
Djuppackning: 458 mm
Förpackningshöjd: 119 mm
Justerbar i höjdled: Nee
Skärm diagonal: 27 "
Upplösning: 1920 x 1080 Pixels
Pekskärm: Nee
Original bildförhållande: 16:9
Betraktningsvinkel, horisontell: 178 °
Betraktningsvinkel, vertikal: 178 °
Skärmform: Flat
Typiskt kontrastförhållande: 1000:1
Marknadspositionering: Gamen
Antal HDMI-portar: 1
Monteringsalternativ för kabellås: Ja
Kabellåsspårtyp: Kensington
Inbyggda högtalare: Ja
Genomsnittlig effekt: 4 W
Strömförbrukning (i standby): - W
Antal högtalare: 2
Display, antal färger: 16,7 miljoen kleuren
Maximal uppdateringshastighet: 75 Hz
HD typ: Full HD
HDMI: Ja
HDMI-version: 1.4
Displayteknik: LED
Respons tid: 5 ms
Pixelpitch: 0.3114 x 0.3114 mm
VESA montering: Ja
Panelmonteringsgränssnitt: 75 x 75 mm
Antireflexskärm: Ja
Ljusstyrka (typiskt): 250 cd/m²
RGB färgrymd: sRGB
Antal DisplayPorts: 1
Energiförbrukning (HDR) per 1000 timmar: - kWu
Energiförbrukning (SDR) per 1000 timmar: - kWu
Enhetsbredd (med stativ): 613.5 mm
Djupenhet (med stativ): 462.6 mm
Enhetshöjd (med stativ): 181.1 mm
Vikt (med stativ): 3900 g
Färgspektrum: 100 procent
Färgdjup: 8 Bit
Typ av panel: IPS
Hörlurarna avstängda: Ja
Bildstorlek (horisontell): 597.888 mm
Bildstorlek (vertikal): 336.312 mm
Stativ ingår: Ja
DisplayPort-version: 1.2a
AC-ingångsspänning: 100 - 240 V
AC-ingångsfrekvens: 50/60 Hz
Strömförbrukning (typiskt): - W
Tiltvinkelområde: -5 - 20 °
lutningsjusteringar: Ja
European Product Register for Energy Labeling (EPREL)-kod: 1180451

Behöver du hjälp?

Om du behöver hjälp med Danby DAS120GBHWDB ställ en fråga nedan och andra användare kommer att svara dig




Inte kategoriserad Danby Manualer

Inte kategoriserad Manualer

Nyaste Inte kategoriserad Manualer