Läs gratis den bruksanvisning för Dayton 3UG73 (24 sidor) i kategorin element. Guiden har ansetts hjälpsam av 19 personer och har ett genomsnittsbetyg på 4.2 stjärnor baserat på 4 recensioner. Har du en fråga om Dayton 3UG73 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/24

Form 5S5433
E
N
G
L
I
S
H
E
S
P
A
Ñ
O
L
F
R
A
N
Ç
A
I
S
Printed in U.S.A.
09663
Version 1
06/2013
Unpacking
Remove the heater from box and
inspect for any damage. If it appears
to be damaged, immediately return.
Check the contents of the box to make
sure it contains one heating unit and
one mounting bracket.
General Safety
Information
When using electric
appliances, basic
precautions should always be followed
to reduce the risk of fire, electric shock
and injury to persons, including the
following:
1.Read all instructions before installing
or using this heater.
2.This heater is hot when in use. To
avoid burns, do not let bare skin
touch hot surfaces. Keep combustible
materials, such as furniture, pillows,
bedding, papers, clothes, etc. and
curtains at least 3 feet (0.9 m) from
the front of the heater.
3.Extreme caution is necessary when
any heater is used by or near children
or invalids, and whenever the heater
is left operating and unattended.
Dayton
®
Electric Utility
Heaters
Operating Instructions & Parts Manual3UG73E and 3UG74E
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
Dayton electric utility heaters are designed to meet a variety of heating
requirements by switching a few wires located in the base of the unit. Heat output
ranges from 6,396 to 17,065 BTU per hour. Features horizontal and vertical flow
(horizontal air throw approximately 18 ft.), built-in thermostat, and high-limit
thermal cutout.
Figure 1
(*) Can be operated at 208V (see Table 1 for ratings).
(**) Heater is shipped from factory wired for these wattages. Heater can be field
adjusted to the other wattages (refer to “Adjusting the Heat Output” on page 4).
Figure 2 –Dimensions
Minimum
Distance to Wall
NOTE:Min. Clearance To Ceiling
When Not Using Mounting
Brackets Is 1
5
/8”
Mounting
Location
6’ Minimum
Distance to Floor
Minimum Distance
from Discharge
to Any Object
Maximum Mounting Height for:
Vertical Air Delivery Unit = 11’
Horizontal Air Delivery Unit = 8’
Front View
Side View
14”
13”
11
1
/4”
5
1
/2”
24”
12
1
/2”
1
3
/4”
1/2”, 3/4”
3UG73E*5000**240/20816020.918.027060˚F17,06512,799
4165240/20816017.415.027060˚F14,21510,659
3332240/20816013.912.027060˚F11,3658,533
2500240/20816010.49.027060˚F8,5336,393
3UG74E5000**208160–24.027060˚F–17,065
4165208160–20.027060˚F–14,215
3332208160–16.027060˚F–11,365
2500208160–12.027060˚F–8,533
Specifications
Amps @Temp.BTU/Hr. @
ModelWattsVoltsPhaseHz240V208VCFMRise240V208V
06/13
5200-11198-000
ISS 1.0
ECR 39427
Produktspecifikationer
| Varumärke: | Dayton |
| Kategori: | element |
| Modell: | 3UG73 |
Behöver du hjälp?
Om du behöver hjälp med Dayton 3UG73 ställ en fråga nedan och andra användare kommer att svara dig
element Dayton Manualer
4 Augusti 2025
element Manualer
Nyaste element Manualer
2 April 2026
2 April 2026
31 Mars 2026
26 Mars 2026
24 Mars 2026
23 Mars 2026
23 Mars 2026
22 Mars 2026
21 Mars 2026
21 Mars 2026