Läs gratis den bruksanvisning för Drayton Lifestyle LP722 (2 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 30 personer och har ett genomsnittsbetyg på 4.8 stjärnor baserat på 8 recensioner. Har du en fråga om Drayton Lifestyle LP722 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/2

Changingthetimings
PresstheSET?buttonandyou’llsee‘SETPROG?’.
Setallweekdays
Firstyousetthetimesthataregoingtobethesameforeach
weekday,thenyoucanselecteachdayindividuallyandmake
anyfurtheradjustments.Ifyouwanteachdaytobequite
different,gostraightto‘Seteachday’.
PresstheYESbutton,andthedisplaywillask‘SETMONtoFRI
PROG?’.
PressYESandyou’llseeON1,thestartofyourfirstheatingperi-
od.Adjustitin1-minutestepsusingthe–and+buttons.
Ifthe–and+buttonsarehelddown,thetimechangesin
10-minutesteps.
PressSET?,andyou’llseeOFF1,theendofyourfirstheating
period.Adjustthisinthesameway,pressSET?,thenrepeat
theprocedureforON2,OFF2,ON3andOFF3.
Seteachday
If,afteryou’vesetOFF3youwanttofine-tuneoneormore
weekdays,pressSET?untilyoufindthefirstdayyouwantto
adjust–thengothroughtheprocedure,alteringanytimeyou
wish.PressSET?tomoveontothenextday.Whenyou’ve
finished,pressSET?untilyousee‘SETSATSUNPROG?’.
Ifyoudon’twanttoalteranyindividualdays,keeppressing
SET?untilyousee‘SETSATSUNPROG?’.
Setweekend
PressYESandalterON1,OFF1,ON2,OFF2,ON3andOFF3
timesinthesameway.
Seteachday
If,afteryou’vesetOFF3forbothSAT&SUN,youwanttofine-
tuneSaturdayorSunday,pressSET?untilyoufindthefirstday
youwanttoadjust–thengothroughtheprocedure,alteringany
timeyouwish.PressSET?tomoveontothenextday.When
youpressSET?aftersettingyourhotwaterforSundays,thepro-
grammerwillgobacktonormaloperation.
Ifyoudon’twanttoaltereitherday,keeppressingSET?
untiltheprogrammergoesbacktonormaloperation.
SAT
THELP11224hrELECTRONICPROGRAMMER
LP112–a24hrprogram,withlinkedcentralheatingandhot
wateronforupto3heatingperiodseachday,andeveryday
thesame.
Ifthetimingshaven’tbeensetforyou,thenyourprogrammer
willstillbeonthefactory-setstandard24hrprogram,with
centralheatingandhotwateroperatingtogetheronthe
samesettingsforeverydayoftheweek.Butit’seasyto
makechanges–justfollowtheinstructions.
Wanttoleaveatimingasitis?PressSET?andmoveonto
thenextone.
Ifyouneedtoresetyourtimingstothestandardprogram
andstartagain,press‘SET’and‘+’togethertogobackto
thepre-setprogram.
Ifyoudon’tpressanythingfortwominut
es,theprogrammer
automaticallygoesbacktonormaloperation.
Thestandardprogram
Yoursystemwillcomeonforupto3heatingperiodsevery
24hrs.ON1startsthefirstone,OFF1finishesit,andsoon.
NoticethatonthestandardprogramON2andOFF2areset
tothesametime.*Thismeansyoursystemwon’trespond,
butifyouwanttoactivatethatmiddleperiod,orchangeany
othertimings–readon.
Changingthetimings
PresstheSET?buttonandyou’llsee‘SETPROG?’.
PresstheYESbutton,andyou’llseeON1,thestartofyourfirst
heatingperiod.Adjustitin1-minutestepsusingthe–and+
buttons.Ifthe–and+buttonsarehelddown,thetimechanges
in10-minutesteps.
PressSET?,andyou’llseeOFF1,theendofyourfirstheating
period.Adjustthisinthesameway,pressSET?,thenrepeatthe
procedureforON2,OFF2,ON3andOFF3.
WhenyoupressSET?aftersettingOFF3,theprogrammerwill
returntonormaloperation.
THELP24124hrELECTRONICPROGRAMMER
LP241–a24hrprogram,withcentralheatingandhotwater
workingindependentlyforupto3heatingperiodseachday,
andeverydaythesame.
Ifthetimingshaven’tbeensetforyou,thenyourprogrammer
willstillbeonthefactory-setstandard24hrprogram,with
centralheatingandhotwateroperatingtogetheronthe
sametimingsforeverydayoftheweek.Butit’seasytomake
changes,andhaveheatingandwaterworkingindependently
–justfollowtheinstructions.
Wanttoleaveatimingasitis?PressSET?andmoveonto
thenextone.
Ifyouneedtoresetyourtimingstothestandardprogram
andstartagain,press‘SET’and‘+’togethertogobackto
thepre-setprogram.
If
youdon’tpressanythingfortwominutes,theprogrammer
automaticallygoesbacktonormaloperation.
Thestandardprogram
Yoursystemwillcomeonforupto3heatingperiodsevery24hrs.
ON1startsthefirstone,OFF1finishesit,andsoon.Noticethaton
thestandardprogramON2andOFF2aresettothesametimefor
bothcentralheatingandhotwater.*Thismeansyoursystemwon’t
respond,butifyouwanttoactivatethatmiddleperiod,orchange
anyothertimings–readon.
Changingthetimings
PresstheSET?buttonandyou’llsee‘SETPROG?’.
DUAL
CHANNEL
LP112,LP241,LP522,LP722
SINGLE
CHANNEL
forheatingORhotwater
LP111,LP711
Technical Helpline: 0333 7000622
Email: [email protected]
Web: www.draytoncontrols.co.uk
forheatingANDhotwater
InstallationInstructions
06490033001ISSL
DUAL
CHANNEL
LP112,LP241,LP522,LP722
SINGLE
CHANNEL
User’sInstructions
TIMESWITCHES
forheatingORhotwater
LP111,LP711
Technical Helpline: 0333 7000622
Email: [email protected]
Web: www.draytoncontrols.co.uk
forheatingANDhotwater
UserInstructions
06490033001ISSL
INSTALLATIONINSTRUCTIONS
PLEASENOTE:INSTALLATIONMUSTONLYBE
CARRIEDOUTBYAQUALIFIEDELECTRICIANOR
HEATINGENGINEER.
MAKESUREMAINSINPUTHASA3AMPFUSE.
TECHNICALDATA
LifestyleProgrammersandTimeswitchesconformtothe
essentialrequirementsoftheseDirectives:
2014/30/EU
– Electromagnetic Compatibility Directive
2014/35/EU – Low Voltage Directive
BEFOREINSTALLATION
First,makesurethemainssupplyisswitchedoff!
PROGRAMMERONLY
Theprogrammermustbesettothetypeofsystemitistocon-
trol.Thelinkonthebackoftheunithastwosettings–PandG.
P=afullypumpedandcontrolledsystem–allowing
heatingandhotwatertobesetseparately.
G=agravity-fedhotwatersystem–whichdoesnotallow
independentsettingofheatingwithouthotwater,though
hotwatercanbecontrolledalone.
USINGANEXISTINGWALL-PLATE
Loosenthesecuringscrewsontheoldprogrammerand
unplugit.Checkthatthere’s70mmclearancetotherightof
thewall-plate,and25mmaboveit.Checkthechartonthe
nextpagetocompareterminalsandifnecessary,changethe
wiringofthewall-platetosuit.NowplugtheLifestyleunitinto
thewall-plateandtightenthesecuringscrews.
Checkthe3Afuse,andswitchonthemains.
FITTINGANEWWALL-PLATE
Theideallocationis1.4mabovefloorlevel,withreasonable
lighting,goodaccess,nocondensation,noextremesof
temperature,andasupportingsurfacethatfullycoversthe
backoftheunit.
Positionwith70mmclearancetotheright,25mmabove,and
sufficientroomtoaccessthesecuringscrewsunderneath.
Fix,withterminalsatthetop,eitherdirecttoaflatwallusingwall
plugsandNo.6x1”(25mm)woodscrews,oronaflushmount-
ingsingleconduitboxtypeUA1(BS4662)usingM3.5x14bolts.
DONOTUSEASURFACEMOUNTINGBOX.
WIRINGTHETIMESWITCH
Makethewiringconnectionsas
above.Notethattheoutput
contactsarevoltage-free,so
powerneedstobeputonto
Terminal1eitherbylinkingfrom
TerminalLorfromaseparate
supplywitha3Afuse.
WIRINGTHEPROGRAMMER
Arrowednumbersrelateto
thejunctionbox.
Consultboilerhandbook
fordetailsofpump
overrunwiring.
ConnectionCharts
WiringColourCodes
GRGrey
YYellow
BKBlack
BLBlue
BRBrown
RDRed
WWhite
OROrange
YGYellow/Green
CCommon
HCallforHeat
SSatisfied
NNeutral
EEarth
LLive
*ThermostatKey
USINGADRAYTONSIMP-L-FIT,ALTHOUGHNOT
NECESSARY,WILLMAKETHISINSTALLATIONEASIER.
SWITCHING
STANDARDPROGRAM
CHHW
ON1–startoffirsttimedperiod6.30am6.30am
OFF1–endoffirsttimedperiod8.30am8.30am
ON2–startofsecondtimedperiod*12.00pm12.00pm
OFF2–endofsecondtimedperiod*12.00pm12.00pm
ON3–startofthirdtimedperiod4.30pm4.30pm
OFF3–finalswitch-offoftheday10.30pm10.30pm
User’sInstructions
PROGRAMMERS
SWITCHINGSTANDARDPROGRAM
ON1–startoffirsttimedperiod6.30am
OFF1–endoffirsttimedperiod8.30am
ON2–startofsecondtimedperiod*12.00pm
OFF2–endofsecondtimedperiod*12.00pm
ON3–startofthirdtimedperiod4.30pm
OFF3–finalswitch-offoftheday10.30pm
INTRODUCTIONCont...
SWITCHING
ON1–startoffirsttimedperiod
OFF1–endoffirsttimedperiod
ON2–startofsecondtimedperiod
OFF2–endofsecondtimedperiod
ON3–startofthirdtimedperiod
OFF3–finalswitch-offoftheday
INTRODUCTION
LifestyleTimeswitcheswillautomaticallycontrolyoursystem
byswitchingitonandoffattimesthatsuityou.Theredlight
onthefrontofthetimeswitchshowswhenit’son.
LP111–a24hrprogram,upto3heatingperiods
eachday,andeverydaythesame.
LP711–a7-dayprogram,allowingfordifferent
timingsoneachdayoftheweek,upto3heatingperiods
eachday.
Iftheengineerhasn’tsetyourtimingsforyou,yourtimeswitch
willworkwithastandardprogramthathasbeensetatthe
factory.Ifthisdoesn’tsuityou,it’sveryeasytochangeit–
whenyou’vereadthisintroductorysection,simplyturnto
thepageforyourtimeswitchmodel.
Remember:
MakeyourchangesusingtheSET?,YES/-,and+buttons.
Youcan’tsetON1asthelasttimingbeforemidnight,butyou
cansetOFF3aftermidnight–providingit’snotmorethan23
hoursand59minutesafterON1.
Youneedtosetthetimingsinsequence–i.e.ON1,OFF1,ON2,
OFF2,ON3,OFF3.Ifyougetoutofsequence,thedisplaywill
flashawarning.
SINGLE
CHANNEL
Timeswitch
DUAL
CHANNEL
Programmer
Lifestyle
SINGLE
CHANNEL
Timeswitch
DUAL
CHANNEL
Programmer
Lifestyle
Whatisaprogrammer?
...anexplanationforhouseholders
Programmersallowyoutoset‘On’and‘Off’timeperiods.
Somemodelsswitchthecentralheatinganddomestichot
wateronandoffatthesametime,whileothersallowthe
domestichotwaterandheatingtocomeonandgooffat
differenttimes.
Setthe‘On’and‘Off’timeperiodstosuityourownlifestyle.
Onsomeprogrammersyoumustalsosetwhetheryouwant
theheatingandhotwatertoruncontinuously,rununderthe
chosen‘On’and‘Off’heatingperiods,orbepermanentlyoff.
Thetimeontheprogrammermustbecorrect.Sometypes
havetobeadjustedinspringandautumnatthechanges
betweenGreenwichMeanTimeandBritishSummerTime.
Youmaybeabletotemporarilyadjusttheheatingpro-
gramme,forexample,‘Override’,‘Advance’or‘Boost’.These
areexplainedinthemanufacturer’sinstructions.
Theheatingwillnotworkiftheroomthermostathasswitched
theheatingoff.And,ifyouhaveahot-watercylinder,the
waterheatingwillnotworkifthecylinderthermostatdetects
thatthehotwaterhasreachedthecorrecttemperature.
Iftheengineerhassetyourprogramandtimings–youwon’t
needtodoanythingelse.Justkeepthisguideinasafeplace
forfuturereference.
Sometimesyoumightneedtochangethewayyouuseyour
systemtemporarily–perhapsduetoanexceptionallycoldday.
Here’showtodoit–withoutaffectingthetimingsinyour
program.
DAY-TO-DAYVARIATIONS
THELP11124hrELECTRONICTIMESWITCH
Switchingonandoff
Over-ridingtheprogram
OFF=continuouslyoff.
TIMED=onforupto3periodsaday.
ONCE=onfor1periodaday,fromthestartofON1
totheendofOFF3.
ON=continuouslyon.
Atthesideofthedisplaythereare
fouroperatingmodes:
UsetheSELECTbuttonundertheflaptochangethemode.
Thiswon’talterthetimingsinyourprogram,whichyoucan
returntobyselectingTIMED.
LP111–a24hrprogram,upto3heatingperiodseachday,
andeverydaythesame.
Wanttoleaveatimingasitis?JustpressSET?andmoveon
tothenextone.
Ifyouneedtoresetyourtimingstothestandardprogram
andstartagain,press‘SET’and‘+’togethertogobackto
thepre-setprogram.
Thestandardprogram
Yoursystemwillcomeonforupto3heatingperiodsevery
24hrs.ON1startsthefirstone,OFF1finishesit,andsoon.
NoticethatON2andOFF2aresettothesametime.*This
meansyoursystemwon’trespond,butifyouwanttoactivate
thatmiddleperiodorchangeanyothertimings–readon.
SWITCHINGSTANDARDPROGRAM
ON1–startoffirsttimedperiod6.30am
OFF1–endoffirsttimedperiod8.30am
ON2–startofsecondtimedperiod*12.00pm
OFF2–endofsecondtimedperiod*12.00pm
ON3–startofthirdtimedperiod4.30pm
OFF3–finalswitch-offoftheday10.30pm
PresstheYESbutton,andyou’llseeON1,thestartofyour
firstheatingperiod.Adjustitin1-minutestepsusingthe–
and+buttons.Ifthe–and+buttonsarehelddown,the
timechangesin10-minutesteps.
PressSET?,andyou’llseeOFF1,theendofyourfirstheating
period.Adjustthisinthesameway,pressSET?,thenrepeatthe
procedureforON2,OFF2,ON3andOFF3.
WhenyoupressSET?aftersettingOFF3,thetimeswitchwill
returntonormaloperation.
OnthefrontofthetimeswitchthereisanAdvance/Boostbutton.
Itallowsyoutoswitchyoursystemeitheronoroff,irrespectiveof
theprogram.Soiftheheatingisoff,andyouwantwarmthnow,
youcaneither–
1.PressAdvancetoswitchiton(ADVwillbedisplayed),anditwill
stayonuntiltheendofthenextperiod.Oriftheheatingison
andyoudon’tneedit,pressAdvanceanditwillgooffuntilthe
beginningofthenextONperiod.
AdvancewillonlyoperateinTIMEDorONCEmodes.
2.Press&HoldBoosttoswitchonforanextrahour(&BSTwill
bedisplayed),thenPressagainfortwo()orthree()hours.
TocancelBoost,PressBoostagain().Oriftheheatingis
alreadyon,usingBoostwillextendthe
ONtimebyone,twoor
threehours.
Changingthetimings
PresstheSET?buttonandyou’llsee‘SETPROG?’.
Iftheengineerhassetyourprogramandtimings–you
wontneedtodoanythingelse.Justkeepthisguideinasafe
placeforfuturereference.
INTRODUCTION
Thereare4modelsintheLifestylerange:
LP112–a24hrprogram,withlinkedcentralheatingandhot
wateronforupto3heatingperiodseachday,andeveryday
thesame.
LP241–a24hrprogram,withcentralheatingand
hotwaterworkingindependentlyforupto3heatingperiods
eachday,andeverydaythesame.
LP522–a5/2-dayprogramallowingfordifferent
timingsattheweekends,withcentralheatingandhotwater
workingindependentlyforupto3heatingperiodseachday.
LP722–a7-dayprogramallowingfordifferent
timingsoneachdayoftheweek,withcentralheatingand
hotwaterworkingindependentlyforupto3heatingperiods
eachday.
Iftheengineerhasn’tsetyourtimingsforyou,yourprogrammer
willworkwithastandardprogramthathasbeensetatthe
factory.Ifthisdoesn’tsuityou,it’sveryeasytochangeit–
whenyou’vereadthisintroductorysection,simplygotothe
sectionthatcontainsyourprogrammermodel.
Remember:
Lifestyleprogrammerswillautomaticallyswitchyourcentral
heatingandhotwateronandoffattimesthatsuityou.
Dependingonyoursystem,centralheatingandhotwatercan
eitherbothcomeonandoffatthesametime,orwork
independently.Theredlightonthefrontoftheprogrammer
showswhemeachoneison
MakeyourchangesusingtheSET?,YES/-,and+buttonson
the programmer, found under the bottom flap.
Youcan’tsetON1asthelasttimingbeforemidnight,butyou
cansetOFF3aftermidnight–providingit’snotmorethan23
hoursand59minutesafterON1.
Youneedtosetthetimingsinsequence–i.e.ON1,OFF1,ON2,
OFF2,ON3,OFF3.Ifyougetoutofsequence,thedisplaywill
flashawarning.
SWITCHING
ON1–startoffirsttimedperiod
OFF1–endoffirsttimedperiod
ON2–startofsecondtimedperi-
od
OFF2–endofsecondtimedperi-
od
ON3–startofthirdtimedperiod
OFF3–finalswitch-offoftheday
Theengineerhassetyourprogramandtimings–you
won’tneedtodoanythingelse.Justkeepthisguideina
safeplaceforfuturereference.
Sometimesyoumightneedtochangethewayyouuseyour
centralheatingorhotwatertemporarily–perhapsduetoan
unusuallycoldday,orexceptionaldemandforhotwater.
Here’showtodoit–withoutaffectingyourprogram.
Switchingonandoff
OnthefrontoftheprogrammertherearetwoAdvance/Boost
buttons–oneforcentralheatingandoneforhotwater.They
allowyoutoswitchyoursystemeitheronoroff,irrespectiveof
theprogram.Soiftheheatingorhotwaterisoff,andyouwant
warmthorhotwaternow,youcaneither–
1.PressAdvancetoswitchiton(ADVwillbedisplayed),andit
willstayonuntiltheendofthenextperiod.Oriftheheating/hot
waterisonandyoudon’tneedit,pressAdvanceanditwillgo
offuntilthebeginningofthenextONperiod.
AdvancewillonlyoperateinTIMEDorONCEmodes.
2.Press&HoldBoosttoswitchonforanextrahour(&BSTwill
bedispl
ayed),thenPressagainfortwo()orthree()hours.
TocancelBoost,PressBoostagain().Oriftheheating/hot
waterisalreadyon,usingBoostwillextendtheONtimebyone,
twoorthreehours.
Over-ridingtheprogram
Oneachsideofthedisplaytherearefouroperatingmodes–
onegroupforcentralheating,theotherforhotwater.Youcan
changemodeswithimmediateeffectbyusingtheappropriate
SELECTbutton.Thiswon’talterthetimingsinyourprogram,
whichyoucanreturntobyselectingTIMED.
OFF=continuouslyoff.
TIMED=onforupto3periodsaday.
ONCE=onfor1periodaday,fromthestartofON1
totheendofOFF3.
ON=continuouslyon.
DAY-TO-DAYVARIATIONS
THELP7117-DAYELECTRONICTIMESWITCH
LP711–a7-dayprogram,allowingfordifferent
timingsoneachdayoftheweek,upto3heatingperiods
eachday.
Wanttoleaveatimingasitis?JustpressSET?andmoveon
tothenextone.
Ifyouneedtoresetyourtimingstothestandardprogramand
startagain,press‘SET’and‘+’togethertogobacktothe
pre-setprogram.
Thestandardprogram
Yoursystemwillcomeonforupto3heatingperiodsevery
24hrs.ON1startsthefirstone,OFF1finishesit,andsoon.
NoticethatON2andOFF2aresettothesametime.*This
meansyoursystemwon’trespond,butifyouwanttoactivate
thatmiddleperiodorchangeanyothertimings–rea
don.
SWITCHING
STANDARDPROGRAM
MON-FRISAT-SUN
ON1–startoffirsttimedperiod6.30am7.00am
OFF1–endoffirsttimedperiod8.30am9.00am
ON2–startofsecondtimedperiod*12.00pm12.00pm
OFF2–endofsecondtimedperiod*12.00pm12.00pm
ON3–startofthirdtimedperiod4.30pm4.00pm
OFF3–finalswitch-offoftheday10.30pm11.00pm
06490033001 ISS L6/06/2016
on the programmer, found under the bottom flap.
LP241Si,LP522Si&LP722SiPROGRAMMERS
LP111Si&LP711SiTIMESWITCHES
Voltage
230Va.c.+10%-10%50Hz
ProgrammerRating
2(1)A230Va.c.eachswitch
TimeswitchRating
2(1)A230Va.c.
Ambienttemp
Operating:0ºto45ºC
Storage:-20ºCto50ºC
Withoutmainspower
Display:blank
Time:alwayskept
Programtimes:alwayspreserved
Programmingresolution
1minute
Wiring
Fixedwiringonly,tocomplywith
currentIEEregulations
MaintenanceMustbemaintainedbyaqualified
electricianorheatingengineer
Pollution degree
Software class
Ball pressure test
temperature
Rated impulse voltage
2
2
75ºC
2.5kV
DraytonTempus6,7NL1234
Drayton LifestyleLP112,LP241,LP522,LP722NL1234
SwitchmasterNL431400,600
(noconnectiontoterminal4on600)
Switchmaster805, 900, 900iNL4231
ACLMP(Towerchron)21
ACLFP(Towerchron)21811610
Tempus3,4,6,7(oldmodels),
DanfossRandall
CP15,CP715,FP15,FP715(Mk18
)ENL1234
DanfossRandall3020P,3060E7642
DanfossRandall4033(link1-6)E765342
DanfossRandall102,102E,102E5,102E7(link6-3)E5612
DanfossRandall701(linkL-5and5-6)ENL31
DanfossRandall702(linkL-5and5-6)ENL4231
DanfossRandall922,972(linkL-2and2-5)ENL1436
DanfossRandallENL3614SET2,SET2E,SET3E,SET3M,FP975
SET5(linkL-2and2-5)
GrasslinTowerchronDP72,QE2NL1234
HoneywellST699/799(linkL-5and5-8)NL7463
HoneywellST6200,ST6300,ST6400,ST6450NL1234
HoneywellST7100(linkL-3and3-6)NL7485
HorstmannENL3614525,527,425Diadem,H21,H27,
H121,Tiara(linkL-2and2-5)
Landis&Staefa*NL1234RWB2,RWB2E,20,40,102,200,
252&270,RWB9
MysonMicrotimer(linkL-5and5-8)NL7463
PottertonMysonNL1234AllEP2000’s,EP3000’s,EP6000’s
(linkL-5andN-N)
PottertonMyson*MiniMinderNL1234
SunvicSelect207, SunPro 2000NL1234
SunvicSP50,SP100(linkL-3)NL1425
DraytonTempus1,2(newmodels)NL1234
Drayton Lifestyle
LP111,LP711, LP111Si, LP711Si
NL1234
Switchmaster300NL41
ACLTC(Towerchron)2147
DraytonTempus1,2(oldmodels)NL1234
Switchmaster980NL41
DanfossRandallTS15,75(Mk18)ENL1425/6
DanfossRandallTS715, TS715SiNL1423
DanfossRandallTS975ENL5461,2,3
DanfossRandallSET1,SET1EENL546
DanfossRandallSET4ENL546
DanfossRandall103,103E,103E5,103E7456312
DanfossRandall911,971ENL5642
GrasslinTowerchronQE1NL24
GrasslinTowerchronT2001,T2001QENL7
HoneywellST6100A,ST6100CNL142
HoneywellST7000B
HorstmannCentaurSC1,SC7
L
Horstmann
CentaurPlus,C11,C17, C17-ZW
NL243
HorstmannEmerald423,PearlAutoNL24
Horstmann517,Coronet,H11,H17ENL34
Landis&StaefaRWB3
NL43
Landis&StaefaRWB30,RWB50,100,152,170
NL443
Landis&StaefaRWB7
PottertonMysonEP4000,4001,4002,5002NL542
SangamoM6
SmithsCentrollerMk1,Mk2NL32
SmithsCentroller30123/4
SmithsCentroller300,980NL41
SunvicSelect107, SunProl1000NL1324
SunvicSP20,SP35NL3545
VennerVenneretteNLLINELOAD
TIMESWITCHTERMINALCOMPARISONS
Earth
Neutral
Live
Common
On
Off
Spare
MAKEMODEL
PROGRAMMERTERMINALCOMPARISONS
CurrentModels
Earth
Neutral
Live
Ch1 on
Chl2 on
Ch3 on
Ch4 on
MAKEMODEL
Discontinued/Competitors’Models
E
46
3
1
SalusEP101, SP120
4
3
NL
Myson
Myson
NL1324
MEPIC
4
Mictrotimer (link L-5 and 5-8)
ENL56
E
NL
4
2
3
3
32
NL1234
British GasEMT2, UT1, UT2
NL1324
Drayton
Drayton
Drayton
NL1234
NL1234
NL1234
SM1
miGenie Wish 1
MiTimeMT711R, MiTime RF Pack1
CurrentModels
Discontinued/Competitors’Models
SangamoM5 (link 1-6)
NL1
8
NL1234
SalusEP200, SP220
MysonMEP2C
NL1234
Drayton
Drayton
Drayton
British Gas
SM2
miGenie Wish 2
MiTime MT721R, MiTimeRF Pack 2 & 3
EMP2, UP1, UP2
NL1234
NL1234
NL1234
NL1234
Cansimplyberemovedfromthebackplateandreplacedwithoutanydisturbancetotheexistingwiring.
Produktspecifikationer
| Varumärke: | Drayton |
| Kategori: | Inte kategoriserad |
| Modell: | Lifestyle LP722 |
Behöver du hjälp?
Om du behöver hjälp med Drayton Lifestyle LP722 ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad Drayton Manualer
25 September 2024
25 September 2024
25 September 2024
25 September 2024
25 September 2024
25 September 2024
25 September 2024
25 September 2024
25 September 2024
25 September 2024
Inte kategoriserad Manualer
Nyaste Inte kategoriserad Manualer
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025