Läs gratis den bruksanvisning för Electrolux EWF2CBPA (2 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 34 personer och har ett genomsnittsbetyg på 4.9 stjärnor baserat på 3 recensioner. Har du en fråga om Electrolux EWF2CBPA eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/2
Electrolux Major Appliances, NA., 10200 David Taylor Drive, Charlotte, NC 28262P/N: 241546116
00005
00005
Substance ReductionNSF
Standard
NSF Reduction
Requirements
Average
Influent
Influent
Challenge
Concentration
Maximum
Permissible
Product Water
Concentration
Maximum
Effluent
Average
Effluent
Average
Percent
Reduction
Minimum
Percent
Reduction
Chlorine taste and odor42>/= 50%1.9 mg/L2.0 +/- 10%n/a0.05 mg/L0.05 mg/L97.40%97.40%
Cyst5399.95% 127500
cnt/mL Min. 50,000n/a1 cnt/L1 cnt/L99.99%99.99%
2,4-D53n/a0.222 mg/L0.210 +/- 10%0.07 mg/L0.043 mg/L0.012 mg/L94.50%80.60%
Alachlor53n/a0.385 mg/L0.04 +/- 10%0.002 mg/L0.002 mg/L0.0012
mg/L 97.00% 95.00%
Atrazine53n/a0.0083 mg/L0.009 +/- 10%0.003 mg/L0.0005
mg/L
0.0005
mg/L 94.00% 94.00%
Lead 8.5 pH53n/a0.147 mg/L0.15 +/- 10%0.01 mg/L0.002 mg/L0.0012
mg/L 99.10% 98.50%
Lead 6.5 pH53n/a0.142 mg/L0.15 +/- 10%0.01 mg/L0.001 mg/L0.001
mg/L 99.30% 99.30%
Mercury 8.5 pH53n/a0.006 mg/L0.006 +/- 10%0.002 mg/L0.0019 mg/L0.0015
mg/L 82.40% 68.20%
Mercury 6.5 pH53n/a0.006 mg/L0.006 +/- 10%0.002 mg/L0.0002
mg/L
0.0002
mg/L 96.50% 96.50%
Lindane53n/a0.0019 mg/L0.002 +/- 10%0.0002 mg/L0.00002
mg/L
0.00002
mg/L 98.90% 98.90%
Toxaphene53n/a0.0155 mg/L0.015 +/- 10%0.003 mg/L0.001 mg/L0.001
mg/L 93.50% 93.40%
Particulate class I42>/= 85%8,966,666
part./mL
Min. 10,000
part./mL >/= 85%14000
part./mL 10050 mL99.90%99.80%
Turbidity53n/a11 NTU11 +/- NTU0.5 NTU0.4 NTU0.1625
NTU 98.50% 96.40%
Endrin5366.60%0.006 mg/L0.006 +/- 10%0.002 mg/L0.0002
mg/L
0.0002
mg/L 96.80% 96.80%
Ethylbenzene5366.60%2.08 mg/L2.1 +/- 10%0.7 mg/L0.0005
mg/L
0.0005
mg/L 99.90% 99.90%
O-Dichloro benzene5366.60%1.8 mg/L1.8 +/- 10%0.6 mg/L
0 0005
.
mg/L
0 0005
.
mg/L 99.90% 99.90%
P-Dichloro benzene5366.60%0.22 mg/L0.225 +/- 10%0.075 mg/L0.0005
mg/L
0.0005
mg/L 99.80% 99.80%
Asbestos53> 99%72 MLF10-100 MLFNA 0.17 MLF0.17 MLF>99.00%>99%
Benzene5366.60%0.016 mg/L0.015 +/- 10%0.005 mg/L0.0005
mg/L
0.0005
mg/L 96.80% 96.80%
Carbofuran5350.00%0.079 mg/L0.08 +/- 10%0.04 mg/L0.0006
mg/L
0.0018
mg/L 97.80% 97.80%
MLF = Million fibers per liter
SYSTEM SPECIFICATION AND PERFORMANCE DATA SHEET
pure advantageTM NGFC-2000 Ice Maker Filter System
APPLICATION GUIDELINES / CONDITIONS OF USE
Water SupplyMunicipal or well applications
Water Temp.Max. 100°F (38°C), Min. 33°F (0.6°C) - For cold water use only
Water Pressure100 psi (690 kPa) Max. 30 psi (207 kPa) Min., as measured at the valve inlet
• Theltercartridgeshouldbereplacedatleasteverysixmonthsfortheproducttoperformasadvertised.PleaserefertotheUseandCareManualforgeneral
operationandmaintenancerequirements.Yourrefrigeratorwillhaveanelectroniclightonthefreezerdoordispenserthatlightsupyellowwhenthelterisalmost
readyforreplacementandlightsupredwhentheltermustbereplaced.Theindicatorispressedforapproximately3-10secondstoresetafterreplacingthe
ltercartridge.PleaserefertotheUse&CareManualforcompleteinstructions.ThewaterlterstatuslightonthismodelisnottestedorcertiedbyNSF.
• Donotusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutadequatedisinfectionbeforeorafterthesystem.Systemscertiedforcyst
reductionmaybeusedondisinfectedwatersthatmaycontainlterablecysts.
 Whiletestingwasperformedunderstandardlaboratoryconditions,actualperformancemayvary.Highsedimentareasmayrequiremorefrequentltercartridgereplacement.
• pure advantageTMNGFC-2000WaterFilterSystemwillabsorbbadtastesandodorsinbothicecubesanddrinkingwater.
SYSTEM SPECIFICATIONS
Flow RateIceMaker-3.4to4.3oz(99-125cc)per6.3secondsat60psi(asmeasuredatvalveinlet)
Dispenser-60ozperminute(0.5gpmor1.9litersperminute)at60psi(asmeasuredatvalveinlet)
Capacity240 gallons (908.5 liters)
SystemConstruction FilterHousingAssembly-Polypropylene Plastic
WaterStorageTank-PolyethylenePlastic
Tubing-PolyethylenePlastic
FilterMedia-ExtrudedCarbonBlock
REPLACEMENT CARTRIDGE INFORMATION
Replacement cartridges are available through your local Electrolux dealer by calling the Consumer Care Center at 1-877-435-3287.
PleasereferenceInstallationInstructionsintheUse&CareManualforreplacingthecartridgeandwarrantyinformation.Estimatedcostforthereplacementltercartridgekit:
Less than $50.00
PERFORMANCE DATA
MODEL: advantagepure TM
NGFC-2000
Usethereplacementcartridgelistedbelow.
The advantagepure TMNGFC-2000systemwiththeFC-300cartridgehasbeentestedaccordingtoNSF/ANSI42/53forreductionof
thesubstanceslistedbelow.Theconcentrationoftheindicatedsubstancesinwaterenteringthesystemwasreducedtoaconcentration
lessthanorequaltothepermissiblelimitforwaterenteringthesystem,asspeciedinNSF/ANSI42/53.
Generaltestwaterparameters;pH=7.5+/-0.5Temp.20°C+/-3°C(68°F+/-5°F)Pressure=60psi(414kPa)@0.5gpm(1.9lpm)