Elektrobock PT741W-EI WIFI Bruksanvisning
Elektrobock
Termostat
PT741W-EI WIFI
Läs gratis den bruksanvisning för Elektrobock PT741W-EI WIFI (2 sidor) i kategorin Termostat. Guiden har ansetts hjälpsam av 2 personer och har ett genomsnittsbetyg på 4.7 stjärnor baserat på 1.5 recensioner. Har du en fråga om Elektrobock PT741W-EI WIFI eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/2

-1 - -2 - -3 - -4 -
PT740W - EI WIFI
PT740B - EI WIFI
PT741W - EI WIFI
PT741B - EI WIFI
The PT74x room thermostats are designed to control electric underfloor or hot water
heating. Control can be done manually or via a smartphone app.
This product is suitable for the standard flush-mounted box.
The installation must be carried out by a person with appropriate electrical
qualifications! Risk of electric shock.
ROOM THERMOSTATS
SERIES PT74X
After connecting to the WiFi network (page 5), we recommend programming and
setting via the application.
SCHEMATIC DIAGRAM
INSTALLATION
DISPLAY DESCRIPTION
PRESET PROGRAM
MANUAL CONTROL AND PROGRAMMING
1. Turning the device on/off
Press the ON/OFF button
.
2. Temperature setting
To decrease the desired temperature, press
or to increase .
3. Clock settings
Press the clock icon button
and then use the up and down arrows to set the
hours, minutes and days. Once set, press the clock button
again to save. .
4. Locking/unlocking the thermostat
By pressing two buttons
for at least 5 seconds, the thermostat is locked or
unlocked.
5. Mode settings
Press the (mode) button
to change the mode from manual to automatic and vice
versa.
In manual mode, the icon
will appear on the display.
In automatic mode, the icon
will appear .
6. Setting weekly programming
We recommend programming and setting via the mobile phone application.
The thermostat allows you to set 6 time and temperature changes each day.
Turn on the thermostat using the button
.
Hold the buttons
and for at least 5 seconds.
Use the mode button
to change times and temperatures according to your
requirements.
For setting use the buttons upwards
and downwards.
The order is: time setting - temperature setting - day of the week setting..
Program settings are made on days 1 to 5 (Monday to Friday), 6 (Saturday), 7 (Sunday).
Monday to Friday have the same program.
SERVICE SETTINGS
OPEN WINDOW DETECTION (7OEN):
When this function is activated, the thermostat will stop heating if it detects a sudden drop in
temperature (by default 2°C within 15 minutes) (constant 9Otp and 8Otl). This is usually caused
by opening a window or door. The open window icon
will appear on the display. The
thermostat will return to its original mode after 30 minutes (constant 0Pdt) or when the desired
temperature is manually changed.
FROST PROTECTION (5Ltp):
After activating the function, when the room temperature drops below the set value, the
thermostat will automatically switch on (the icon will appear on the display). The thermostat will
return to normal mode when the temperature rises. If this function is active, it also works in OFF
mode (the snowflake icon will be lit on the display)..
Entering service settings::
1. Turn off the thermostat using the button
.
2. Press and hold the and buttons
and for at least 5 seconds.
3. The service menu appears on the display (see table below).
4. You can change individual values using the and arrows
, and use the
button
to scroll between individual parameters.
5. After setting all desired changes, press the button
to save.
PT740W - EI WIFI, PT740B - EI WIFI
PT741W - EI WIFI, PT741B - EI WIFI
The current
instructions can be
found at
www.elektrobock.cz
PT74XY-EI WiFi
Blanenská 1763
Ku im 66434ř
w w w.elbock.cz
1 2
3 4
5
6
N1L 1
N L
95~240 V AC
Imax = 16A
L O AD
NT C
IP20
Product Nr.:
WiFi module : 2.4 GHz
Install the thermostat in a suitable location where its operation will not be affected by direct
flow of warm air from the heater, sunlight and other disturbing influences. Also avoid mounting
on an external wall. Follow the illustration pictures for installation.
The external floor sensor (length 3 m, PVC plastic housing) must not be routed parallel to
power cables! It can be extended to a maximum length of 15 meters.
1. Turn off the power.
2. Connect the power cord and other devices to the terminals.
3. Fix the thermostat board into the wall box on the wall.
4. Connect the LCD board to the thermostat board.
day indication
interval
current time
current temperature
heating indication
„Open window“
function
change
of mode
time
ON/OFF
upwards downwards
indikace WiFi
AUTO-mode
MANU-mode
required temperature
anti-freeze protection
key lock
day indication
MANU-mode
AUTO-mode
current temperature
interval
required temperature
indikace WiFi
current time
anti-freeze protection
key lock
heating indication
„Open window“
function
change
of mode
time
ON/OFF
oder
1 2
3 4
5
6
N1L1
N L
95~240 V AC
Imax = 16A
NTC
upwards downwards
Code Choice default Details
1Adj
Temperature correction (internal sensor)
-2
-9°C +9°C~
2Sen Sensor type In
In: internal sensor (for temperature
control and regulation)
OU: external sensor (for floor control
and protection)
AL: internal/external sensor (internal
sensor is for room temperature
control, external sensor is for floor
temperature protection.)
3Lit Temperature limitation 50.0
5°C +60°C, the sensor should ~
select AL, once the temperature
is higher than this limit, the output
will be turned off and wait until the
temperature decreases. Then the
output will be restored.
4dif Hysteresis settings 1
0.5°C +5°C~
5Ltp Anti-freeze function Off
On: anti-freeze function on
Off: anti-freeze function off
6Hit
Setting the upper
temperature limit
45
35°C +95°C~
7OEN Open window detection OFF
On:open window detection enabled
Off: open window detection disabled
8Otl Detection time 15
2 min 30 min~
9Otp Temperature drop in detection 2
2°C 4°C~
0Pdt Return to previous state 30 10-60 minutes
AFAC Factory settings -
When “---“ is displayed, then hold
the button for 5 seconds until “---“
appears. Reset completed
Time period
Mo-Fr Saturday Sunday
Time
Temperature
Time
Temperature
Time
Temperature
16:30 21°C 6:30 21°C 6:30 21°C
28:00 18°C 8:00 18°C 8:00 18°C
311:30 21°C 11:30 21°C 11:30 21°C
412:30 18°C 12:30 18°C 12:30 18°C
518:00 21°C 18:00 21°C 18:00 21°C
622:30 16°C 22:30 16°C 23:00 16°C

-5 - -6 - -7 -
WIFI CONNECTION
Before using the thermostat for the first time, you must correctly configure the Wi-Fi
network using your smartphone or tablet.
This will allow for easy communication between your devices.
1. Download the app.
Download the Smart Life or Tuya app to your mobile phone using the QR code. You can
also use the Apple Store or Google Play to download the app.
2. Create an account and log in
Open the app, register or log in to your account. You will need a phone number or email to
register.
You will then receive a verification code to verify that it is you.
3. Anschließen des Thermostats an die Applikation
On the thermostat, press the
and buttons simultaneously for at least 5 seconds until
the icon
starts flashing on the display.
Return to the app, search for your thermostat, and pair it.
Press the + in the upper right corner to add your device. Select “Small Home Appliances”,
then click “Thermostat”, then select your network and return to the app, enter the wireless
network password and confirm, the app will automatically connect. It can usually take 5 to
90 seconds to complete.
The device name can be edited when everything is connected properly.
On/off button. This button turns the thermostat on and off.
Mode button, switching between manual and automatic mode.
Weekly program setting button, press it to set weekly programming
Button for setting more advanced settings.
Programming the thermostat in the application
After proper pairing, press the button
in the main menu and you can continue to set the
weekly schedule.
Device sharing via app
Press the button in the upper right corner of the main screen of the application, then “share
devices”, add an account and confirm.
More advanced settings in the app
Press the button
in the app and remember that the thermostat must be turned off for all
these settings to be saved.
Using voice control via the app
Press the button in the upper right corner of the main screen of the application. Select the
service “Third-party Control” and confirm it.
The service works only in English.
TROUBLESHOOTING AND SOLUTIONS
ELEKTROBOCK
Pb
The warranty period is 2 years. In the case
of warranty and post-warranty service, send
the product to the address of the distributor
or importer.
ELEKTROBOCK MTF s.r.o.
Blanenská 1763
Kuřim 664 34
www.elbock.cz
Technical parameters
Power supply 2 30 V AC/ 50 Hz
Consumption < 1.5 W
WiFi 2.4 GHz
Hysteresis 0.5 to 5°C
Temperature range internal sensor
+5°C to 49°C in 0.5°C steps
Temperature range external sensor
+5°C to 99°C in 0.5°C steps
Minimum indication jump 0.5°C
Measurement accuracy ± 1°C
Degree of protection IP20
Protection class II
Output max. 16 A (resistive load)
Working temperature 0°C to +45°C (RH < 95%)
LEAD FREE
Im Einklang mit RoHS
problem solution
1Everything is rightly
connected, but the display
doesn‘t work.
Check for loose terminals between the
LCD and the power supply unit
2The room temperature is
different from the actual
temperature.
Perform calibration in advanced settings
Produktspecifikationer
Varumärke: | Elektrobock |
Kategori: | Termostat |
Modell: | PT741W-EI WIFI |
Behöver du hjälp?
Om du behöver hjälp med Elektrobock PT741W-EI WIFI ställ en fråga nedan och andra användare kommer att svara dig
Termostat Elektrobock Manualer
17 Juni 2025
20 September 2024
15 September 2024
14 September 2024
14 September 2024
14 September 2024
14 September 2024
14 September 2024
6 September 2024
5 September 2024
Termostat Manualer
- GENERAL Life
- Perel
- IMIT
- Vasco
- Oertli
- Noma
- POER
- ORNO
- Velleman
- Tellur
- Watts
- EQ-3
- Westfalia
- Busch-Jaeger
- Drayton Erie
Nyaste Termostat Manualer
14 Juni 2025
9 April 2025
7 April 2025
7 April 2025
6 April 2025
6 April 2025
6 April 2025
5 April 2025
4 April 2025