Festo CACR-KL2-67-W1800 Bruksanvisning

Festo Inte kategoriserad CACR-KL2-67-W1800

Läs gratis den bruksanvisning för Festo CACR-KL2-67-W1800 (2 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 22 personer och har ett genomsnittsbetyg på 3.6 stjärnor baserat på 11.5 recensioner. Har du en fråga om Festo CACR-KL2-67-W1800 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/2
Michael Koch GmbH, Zum Grenzgraben 28, 76698 Ubstadt , Tel.: +49 7251 9626200-Weiher, Germany
mail@bremsenergie.de, www.bremsenergie.de, mail@brakeenergy.com, www.brakeenergy.com
Dbl- -BWD600200K03LIP65FE_deu engl_20210723.docx
Brake resistor - BWD600 LIP65FE200K03
CACR- - - KL2 67 W1800
Description:
Short protecting- -proof, -circuit self
1)
resistor unit for operation on converters (brake transistors) consisting of
3 resistor modules in anodized aluminium casings. Protection class according to IP65
2)
, interconnected by
spring- type terminals. For detailed measurements, see technical drawing (on request).
Nominal capacity (W)
Dimensions LxWxH (mm)
Resistance values (Ohm)
72 180 ( 00 at ED = 35%, ϑ
A
= 20°C)
229 91 x 216 x ,5
66,7
Technical data:
Parameters
Symbol
Value
Unit
Conditions
Tolerance
± 5
%
Room temperature
Weight
m
approx 4,5
kg
Connction data terminal
Conductor cross- section
6 Max. mm
2
Depending on the design of the cable
cross- section
Storing temperature
ϑ
S
- 25 ... +85
°C
Limit values (ϑ
A
)= 20°C, if nothing else is stated :
Parameters
Symbol
Value
Unit
Conditions
Max. permissible operating
voltage
U
B
700 AC
1000 DC
V
considering self protection
1)
U
B
600 AC
#
*
8 50 DC*
V
considering CSA
#
and UL*
Energy consumption
E
13
26
kJ
with 1,2s (1% ED)
with 7,2s (6% ED)
Insulation voltage
U
ISO
4000
V
AC; f = 50 Hz; t = 1 s
Max. permissible casing
temperature
ϑ
C
250
°C
free convection
Temperature coefficient
TK
20 ... 100
10
-6
/K
Insulation resistance
R
ISO
100
M
U
MEAS
= 1000 VDC
Inductance
L
30
µH
f = 300 kHz, U
MEAS
= 50 mV
Capacity against housing
C
300
pF
f = 300 kHz, U
MEAS
= 50 mV
Thermic time factor
τ
Approx 600
sec
Casing BWD600xxx
Max. permissible wire temperature
ϑ
hot
max. + 600
°C
Approbation
cCSAus (CSA file# 210040)
cURus (UL file# E233422)
(both based on CSA-C22.2
and UL 508)
1):
Self protection: At four time type capacity and free convection : Warning
1. No short circuit Mounted in areas without
2. No fault to frame free air change surface
3. Self-extinguishing no fire temperatures up to
4. No melting of casing 350 degrees Celsius can
be reached.
2):
Test conditions: Water jet from nozzle 6,3mm inside diameter, flow rate 12,5l/min +/ 5%, water p- ressure according to volume flow,
distance 2,5-3m, test duration 3min
*Sc = single components
CACR-KL2-67-W1800 | 8164626 [8164628] 2021-08a


Produktspecifikationer

Varumärke: Festo
Kategori: Inte kategoriserad
Modell: CACR-KL2-67-W1800

Behöver du hjälp?

Om du behöver hjälp med Festo CACR-KL2-67-W1800 ställ en fråga nedan och andra användare kommer att svara dig