Läs gratis den bruksanvisning för Festo OVEL-7-H-15-P-VQ4-UC-C-A-H3 (4 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 11 personer och har ett genomsnittsbetyg på 4.9 stjärnor baserat på 6 recensioner. Har du en fråga om Festo OVEL-7-H-15-P-VQ4-UC-C-A-H3 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/4

OVEL
Vacuum generator
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
Operating instruction
8194696
2023-08b
[8194698]
8194696
Translation of the original instructions
© 2023 all rights reserved to Festo SE & Co. KG
IO-Link is a registered trademark of its respective trademark holder in certain
countries.
1
Applicable documents
All available documents for the product
è
www.festo.com/sp.
Documents Product Content
Operating instructions Pressure transmitter SPTE –
Operating instructions Pressure sensor SPAE –
Tab. 1:
Applicable documents
2 Safety
2.1
Safety instructions
–Only use the product in its original condition without unauthorised modifica-
tions.
–Before working on the product: switch off the power supply.
–Use the product only inside buildings.
–
Take into account the ambient conditions at the location of use.
–The product is intended for use in industrial environments.
The product may generate high frequency interference, which may require
interference suppression measures in residential areas.
–Observe the specifications on the product labelling.
2.2 Intended use
The vacuum generator is used to generate a vacuum.
2.3 Training of qualified personnel
Work on the product may only be carried out by qualified personnel who can
evaluate the work and detect dangers. The qualified personnel have skills and
experience in dealing with electropneumatic (open-loop) control technology.
2.4 UL/CSA certification
In combination with the UL inspection mark on the product, the information in this
section must also be observed in order to comply with the certification conditions
of Underwriters Laboratories Inc. (UL) for USA and Canada.
UL/CSA approval information
Product category code QUYX, QUYX7
File number E322346
Considered standards UL61010-1, CAN/CSA C22.2 No. 61010-1
UL mark
Tab. 2:
UL/CSA certification information
WARNING
The unit shall be supplied by a power source which fulfils the requirements on a
limited-energy circuit in accordance to IEC/EN/UL/CSA 61010-1 or on a Limited
Power Source (LPS) in accordance to IEC/EN/UL/CSA 60950-1 or IEC/EN/UL/CSA
62368-1 or a Class 2 circuit in accordance to NEC or CEC.
3
Additional information
–Contact the regional Festo contact if you have technical problems
è
www.festo.com.
–Accessories and spare parts
è
www.festo.com/catalogue.
4 Product design
5
6
4
7
8
9
11 10
1
2
3
4
Fig. 1: Product design OVEL-...-H3
1
Supply port for ejector pulse,
optional
2
Supply port
3
Solenoid valve for vacuum gener-
ation
4
Electrical connection, H3
5
Flow control screw to adjust the
intensity of the ejector impulse
6
Solenoid valve for ejector pulse,
optional
7
Vacuum sensor, pressure sensor
optional
8
Exhaust port, optional silencer
9
Vacuum generator cartridge
10
Vacuum port
11
Housing with mounting holes
4
6
7
8
9
10
1
2
3
4
5
11
Fig. 2: Product design OVEL-...-R8
1
Supply port for ejector pulse,
optional
2
Supply port
3
Solenoid valve for vacuum gener-
ation
4
Electrical connection, M8
5
Flow control screw to adjust the
intensity of the ejector impulse
6
Solenoid valve for ejector pulse,
optional
7
Vacuum sensor, pressure sensor
optional
8
Exhaust port, optional silencer
9
Vacuum generator cartridge
10
Vacuum port
11
Housing with mounting hole
5 Function
–
The solenoid valve for vacuum controls the supply of compressed air for gener-
ating vacuum. A vacuum is generated so long as the vacuum solenoid valve is in
the switching position.
–
The ejector pulse solenoid valve generates an ejector pulse to release the
workpiece safely from the suction cup with connector and to purge the vacuum
quickly. A separate operating pressure can be created for the ejector pulse
through the optional supply port.
–
The vacuum sensor monitors the setpoint value for the generated vacuum.
Produktspecifikationer
| Varumärke: | Festo |
| Kategori: | Inte kategoriserad |
| Modell: | OVEL-7-H-15-P-VQ4-UC-C-A-H3 |
Behöver du hjälp?
Om du behöver hjälp med Festo OVEL-7-H-15-P-VQ4-UC-C-A-H3 ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad Festo Manualer
30 Mars 2025
30 Mars 2025
30 Mars 2025
30 Mars 2025
30 Mars 2025
30 Mars 2025
30 Mars 2025
30 Mars 2025
30 Mars 2025
30 Mars 2025
Inte kategoriserad Manualer
- IKEA
- DB Technologies
- Audient
- OM SYSTEM
- Ergotools Pattfield
- Home Easy
- Tusa
- Lampa
- Walther
- Manitowoc
- EGO
- Shure
- August
- Ardes
- ICC
Nyaste Inte kategoriserad Manualer
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025