Festo VAMC-B10-20-CH2 Bruksanvisning
Festo
Inte kategoriserad
VAMC-B10-20-CH2
Läs gratis den bruksanvisning för Festo VAMC-B10-20-CH2 (2 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 13 personer och har ett genomsnittsbetyg på 4.6 stjärnor baserat på 7 recensioner. Har du en fråga om Festo VAMC-B10-20-CH2 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/2

Montageanleitung (Original: de)
8031237
1311NH
†‡
Abdeckkappe
VAMC-B10-20-CH2
Festo SE & Co. KG
Postfach
73726 Esslingen
Deutschland
+49 711 347-0
www.festo.com
1. Teileliste
19442d_1
1 Abdeckkappe (10x)
19442d_2
Nicht im Lieferumfang:
2 Magnetventil
VUVS-L20/25/30,
VSNC
(1x)
2. Bestimmungsgemäße Verwendung
Abdeckkappe VAMC-B10-20-CH2:
Manuelle tastende Betätigung des Magnetventils 2 ( Abschnitt 4a).
Sperrung der manuellen Betätigung des Magnetventils Abschnitt 4b). 2 (
3. Hinweise zur Montage
Hinweis
Funktionsstörung durch unsachgemäße Montage.
Druckluft vor Montagearbeiten abschalten.
Handhilfsbetätigung (A) vor
der Montage auf unbetätigt
stellen. unbetätigt betätigt
19442d_3
Info
Falls die Handhilfsbetätigung auf betätigt gestellt ist, rastet die Abdeckkap-
pe 1 nicht ein.
4. Montage
4a. Montage für tastende Betätigung
19442d_5
Abdeckkappe 1 wie darge-
stellt montieren
(Hinweis).
Kontrolle:
Öffnung (B) ist dem Magne-
ten (C) abgewandt.
19442d_7
Schraubendreher (D) zur Be-
tätigung in Pfeilrichtung
bewegen.
4b. Montage als Sperrfunktion
Info
Die Abdeckkappe 1, um 180° gedreht montiert, verhindert die Betätigung.
19442d_8
Abdeckkappe 1 wie darge-
stellt montieren
(Hinweis).
Kontrolle:
Öffnung (B) ist dem Magne-
ten (C) zugewandt.
5. Demontage
19442d_6
Schraubendreher (D) in die
Öffnung (E) schieben.
Schraubendreher (D) in
Pfeilrichtung bewegen.
1
2
1
1
A
D
Klinge
3 mm
D
Klinge
3 mm
E
C
C
B
B

Assembly instructions (original: de)
8031237
1311NH
†‡
Cover cap
VAMC-B10-20-CH2
Festo SE & Co. KG
Postfach
73726 Esslingen
Germany
+49 711 347-0
www.festo.com
1. Parts list
19442d_1
1 Cover cap (10x)
19442d_2
Not included in delivery:
2 Solenoid valve
VUVS-L20/25/30,
VSNC
(1x)
2. Intended use
Cover cap VAMC-B10-20-CH2:
Manual non-detenting actuation of the solenoid valve 2 ( section 4a).
Blocking the manual actuation of the solenoid valve 2 ( section 4b).
3. Notes on assembly
Note
Malfunction due to incorrect assembly.
Switch off compressed air before assembly work.
Set manual override (A) to
unactuated prior to assem-
bly. unactuated actuated
19442d_3
Information
If the manual override is set to actuated, the cover cap 1 will not engage.
4. Assembly
4a. Assembly for non-detenting actuation
19442d_5
Mount cover cap 1 as
shown
(Note).
Check:
Orifice (B) is located on the
opposite side to magnet (C).
19442d_7
To actuate, move screw-
driver (D) in the direction of
the arrow.
4b. Assembly as a blocking function
Information
When mounted and rotated by 180°, the cover cap 1 prevents actuation.
19442d_8
Mount cover cap 1 as
shown
(Note).
Check:
Orifice (B) is located on the
side facing magnet (C).
5. Dismantling
19442d_6
Insert screwdriver (D) into
the orifice (E).
Move screwdriver (D) in the
direction of the arrow.
1
2
1
1
A
D
Blade
3 mm
D
Blade
3 mm
E
C
C
B
B
Produktspecifikationer
Varumärke: | Festo |
Kategori: | Inte kategoriserad |
Modell: | VAMC-B10-20-CH2 |
Behöver du hjälp?
Om du behöver hjälp med Festo VAMC-B10-20-CH2 ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad Festo Manualer
30 Mars 2025
30 Mars 2025
30 Mars 2025
30 Mars 2025
30 Mars 2025
30 Mars 2025
30 Mars 2025
30 Mars 2025
30 Mars 2025
30 Mars 2025
Inte kategoriserad Manualer
- ViewZ
- Hecate
- Lexicon
- Teesa
- For_Q
- Buffalo
- Masterbuilt
- Zhiyun
- Ozone
- Roidmi
- Tronic
- Anslut
- Hawk-Woods
- Shure
- Horizon
Nyaste Inte kategoriserad Manualer
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025