Läs gratis den bruksanvisning för GE Profile PD900DPBB (24 sidor) i kategorin Ugn. Guiden har ansetts hjälpsam av 2 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 1.5 recensioner. Har du en fråga om GE Profile PD900DPBB eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/24

1
31-10829GE10-11
BEFORE YOU BEGIN
Read these in struc tions care ful ly and completely.
•IMPORTANT —Savetheseinstructionsfor
localinspector’suse.
•IMPORTANT —Observeallgoverning
codesandordinances.
•Note to Installer –Besuretoleavethese
instructionswiththeconsumer.
•Note to Consumer –Keeptheseinstructionsfor
futurereference.
•Skill level –Installationofthisappliancerequiresa
qualifiedinstallerorelectrician.
•Properinstallationistheresponsibilityoftheinstaller.
•ProductfailureduetoimproperinstallationisNOT
coveredunderthewarranty.
30” Electric
Drop-In Ranges
Installation
Instructions
Questions?Call800.GE.CARES(800.432.2737)orVisitourWebsiteat:www.GEAppliances.com.
InCanada,call1.800.561.3344orvisitwww.GEAppliances.ca.
•ATTENTION INSTALLER: Allelectricdrop-inrangesmustbehardwired(directwired)intoan
approvedjunctionbox.AplugandreceptacleisNOTpermittedontheseproducts
.
FOR YOUR SAFETY
WARNINGBeforebeginningtheinstallation,switchpoweroffattheservicepanelandlockthe
servicedisconnectingmeanstopreventpowerfrombeingswitchedonaccidentally.Whentheservice
disconnectingmeanscannotbelocked,securelyfastenaprominentwarningdevice,suchasatag,totheservice
panel.
WARNINGTheinformationinthismanualmustbefollowedtominimizetheriskoffire,electricshock,
ortopreventpropertydamage,personalinjuryorlossoflife.
MATERIALS YOU MAY NEED
JunctionBox
WireNuts
StrainReliefClampfor1/2”Conduit
TOOLS YOU MAY NEED
1/8”DrillBitandElectricDrill PhillipsScrewdriver
Level FlatheadScrewdriver
TapeMeasure 1/4”NutDriver
StraightedgeorSquare Hammer
HandorSaberSaw Pencil
SafetyGlasses
A child or adult can tip the range and be killed.
Verify the anti-tip bracket has been properly installed
and engaged.
Ensure the anti-tip bracket is -engaged when the range re
is moved.
Do not operate the range without the anti-tip bracket in
place and engaged.
Failure to follow these instructions can sult in death or re
serious burns children or adults.to
Tip-Over Hazard
WARNING
Oven
Anti-Tip Bracket
Countertop or
Wood Block
Rear
Wall

2
InstallationInstructions
Failuretoremovepackagingmaterialscouldresultindamagetotheappliance.Removeallpackingpartsfrom
oven,racks,andheatingelements.Removeprotectivefilmandlabelsontheouterdoorandcontrolpanel.
Alsoremoveplasticontrimsandpanelandalltapearoundtheoven.Openovendoorandremoveliterature
packandovenracks.Removethebottomtrimfromthesideoftheoven.Itwillbeinstalledattheendofthe
installationprocess.Thetrimiswrappedseparatelyinaplasticbagwhichwillalsocontainthe4screwsto
securethebottomtrimandthe2shoulderscrewsusedtosecuretheproducttothecabinet.
1REMOVE PACKAGING MATERIALS
Allow30”minimumclearance
betweensurfaceunitsandbottom
ofunprotectedwoodormetal
cabinet.Allowa24”minimum
whenbottomofwoodormetalis
protectedbynolessthan1/4”thick
flameretardantmillboardcovered
withnotlessthanNo28MSGsheet
metal(.015”),.015”thickstainless
steel,.024”aluminumor.020”
copper.
NOTE: Drop-In Ranges are designed to hang
from the countertop only. Do not install on a
platform or sup port rails.
2PREPARING THE OPENING (FOR INDOOR USE ONLY)

3
InstallationInstructions
2 PREPARING THE OPENING (Continued)
TheStandardInstallationofthisDrop-InRangeistohang
bythecountertoponthesidemetalflangesunderglass
cooktop.This Range must not be installed on a base or
sub structure (2”x 4” support).
Iftheconstructionofyourcabinetcannotprovidea
1/4”flatareaatthebackofthecountertopopening,
considerchangingthecountertoptoaccommodatethis
dimension.Iftheareaisnotflat,excesstensionmay
beappliedtotheglasscooktop,causingbreakageand
voidingthewarranty.
•Countertopthickness1-1/4”min.isrequiredtosupporttheproduct.Bracesmustbeinstalledbetweenthe
undersideofthecountertopandthecabinetifrequiredtoobtain1-1/4”minimumthickness(eachside).
•Makesurethewallcoverings,countersandcabinetsaroundtheovencanwithstandtheheat(upto200°F
(93.3°C)generatedbytheoven.
•Thisappliancehasbeenapprovedfor0”spacingtoadjacentsurfacesabovethecooktop.However,a6”
minimumspacingtosurfaceslessthan15”abovethecooktopandadjacentcabinetisrecommendedto
reduceexposuretosteam,greasesplatterandheat.
•Locatethewiringjunctionboxattherearofthecutout.Thedimensionfromthetopofthewiringjunction
boxtothecountertopmustbeaminimumof28-1/2”.Theboxmustnotextendmorethan3”offtheplane
ofthewall.Thejunctionboxmustbelocatedwhereitwillallowconsiderableslackintherangeconduit,so
thattherangecanbepulledoutforserviceifnecessary.
Wall
1/4”min.flat
23-3/16”
9/16”min.
flat
9/16”min.
flat
29-15/16”–30-1/16”
smoothcut
25”
typically 1/4”
R
Flat
area
Countertop
Rangesupport
Produktspecifikationer
Varumärke: | GE |
Kategori: | Ugn |
Modell: | Profile PD900DPBB |
Färg på produkten: | Zwart |
Inbyggd display: | Nee |
Sladdlängd: | 1.8 m |
Snäll: | Multistyler |
Tillgångar: | - W |
Automatisk avstängning: | Nee |
Teknologi: | Warm |
Justerbar termostat: | Nee |
Antal per paket: | 1 stuk(s) |
Förvaringsväska: | Ja |
Uppvärmningstid: | 60 s |
Jonisk funktion: | Nee |
Keramiskt värmesystem: | Ja |
Uträtning av håret: | Ja |
Curling hår: | Ja |
Haartextureren: | Ja |
Hårtorkning: | Nee |
Vridbar sladd: | Ja |
AC-ingångsspänning: | 220 - 240 V |
AC-ingångsfrekvens: | 50/60 Hz |
Behöver du hjälp?
Om du behöver hjälp med GE Profile PD900DPBB ställ en fråga nedan och andra användare kommer att svara dig
Ugn GE Manualer
1 April 2025
31 Mars 2025
9 Januari 2025
8 Januari 2025
7 Januari 2025
28 December 2024
28 December 2024
28 December 2024
17 December 2024
17 December 2024
Ugn Manualer
- Krefft
- Petromax
- Kucht
- Daewoo
- La Cornue
- Novy
- JennAir
- Pit Boss
- Eldom
- Sharp
- Svan
- Cambridge
- Lacunza
- Cecotec
- UGo
Nyaste Ugn Manualer
16 Juni 2025
16 Juni 2025
16 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025