Giga Copper G4202T Bruksanvisning
Giga Copper
Inte kategoriserad
G4202T
Läs gratis den bruksanvisning för Giga Copper G4202T (5 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 18 personer och har ett genomsnittsbetyg på 4.1 stjärnor baserat på 9.5 recensioner. Har du en fråga om Giga Copper G4202T eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/5

G4202T
G.hn Master and Client
Quick start guide
For further informaon and purchase enquiries
please contact info@gigacopper.net
1. Introducon
With the G.hn modem G4202T you can easily extend
your network via exisng data and telephone cables.
The devices are also suitable for the distribuon of ber
opc connecons from the ONT to the router via exisng
telephone line.
The modem can use any type of cable - both twisted pair
and non-twisted pair - for data transmission and
achieves a speed of approx. 1500 Mbit/s (sum of both
transmission direcons).
The devices are always connected in pairs - a master and
a client. The master determines how fast the data is
transferred towards the client and back
(download/upload).
In networks with several clients, a G.hn switch can be
used instead of several master modems (see
Installaon). This enables the central administraon of
all G.hn components.
2. Package content
G4202T Master or G420 Client 2T
DC-12V/1A Power adapter
RJ11/RJ11 telephone cable , 4- wire (SISO and MIMO) 1.5m
TAE-F/RJ11 , 4- pole (SISO and MIMO) plug
3. Technical data
Dimensions : 103 * 66 * 27 : mm
Weight: 0,19 kg
Operang temperature: 0°C - 40°C
Power consumpon: < 3 Wa
4. G.hn Specicaon
G.hn Wave2, 2-200 MHz
Connecon type: SISO (1 wire pair, 2-200MHz) and
MIMO (2 wire pairs, 2- MHz) 100
Total bandwidth ca. 1500 Mbit/s –
(Sum of Download and Upload)
Spling of the bandwidth variable ex works –, :
70% Download (from master client) to
30% Upload (from client master) to
Maximum permissible aenuaon of the cable
connecon: 75dB
5. Interfaces
Panel and LED descripon
Labelling
Descripon
12V DC
Power input
RST
Recessed reset buon (15 Sec .)
LINE
G.hn port
G1, G2
2x 1 Gigabit Ethernet Port
PHONE
Analog phone port (RJ45)
PWR LED
Displays power availability
LINE LED
Status of the G.hn connecon
(Green - OK, Yellow - weak signal,
O - no connecon)
G1/G2 LED
Ethernet Connecon Status

6. Installaon
Variant 1 Point- - : one master and client – „ to Point “
Variant 2 Connecon to the Switch G4224T or G4200- –8T/4T
7. Connecon type and wire assignment on device (RJ45 plug)
The G.hn connecon can be established either via one wire pair (connecon type SISO PHONE ) or = G.hn prole “ 200MHz”
via two wire pairs (connecon type MIMO PHONE ). The connecon type must be = G.hn prole “ 100MHz MIMO”
congured via web interface in both modems or via the G.hn switch.
The default seng PHONE is one wire pair connecon (“ 200MHz”).
Wire assignment SISO
Wire assignment MIMO

8. Installaon notes
The wires of a pair can be connected straight or crossed.
Maximum range of the G.hn connecon depends on the type of cable used, the connecon type and the environment.
Typical values for a 0.5 mm twisted pair cable: connecon possible up to approx. 600/800 metres (SISO/MIMO),
maximum bandwidth of 1500 Mbit/s - up to approx. 100/200 metres (SISO/MIMO).
For longer cables ( approx. 100-150m), the bandwidth can be increased by up to 15% (SISO) resp. up to 25% (MIMO) up
by adjusng the signal level. For this purpose, the "Range opmizaon model" must be set to "Long" in the web
interface of both devices resp. the "LongRangeMode" seng must be acvated in the G.hn switch.
The negoated bandwidth can be queried via the web interface of the devices (see point 11).
The bandwidth split of the G.hn connecon is variable. It can be set between 80/20% and 20/80%. In the factory seng,
70% of the bandwidth is reserved for download (direcon master to client) and 30% for upload (direcon client to
master). The allocaon can be congured via master web interface (menu G.hn DownStream / UpStream Rao) resp. via
the G.hn switch.
9. Administraon
10. IP address
The devices do not require IP addresses from the local network segment during operaon, because they transmit the data
trac via the MAC addresses. In the factory seng, they do not obtain any addresses from the local DHCP server.
If desired, stac IP addresses can be congured or the DHCP client can be acvated ("IP" menu in the web interface).
11. Query of the negoated bandwidth
The negoated bandwidths for both transmission direcons can be queried via web interface of each modem. The values
shown are gross data transmission rates on physical layer (PHY). Transmission rate on applicaon layer is 15-20% lower.
IP-Adress: 192.168.10.252 (Master), 192.168.10.253 (Client). Login passwort: paterna Factory reset passwort: betera ,
Login via Webinterface
Connect your computer to the G.hn modem via the GE
port..
Assign a xed IP address to your computer, e.g.
192.168.10.100 (network mask 255.255.255.0).
Open a web browser and connect to 192.168.10.252 or
192.168.10.253
Login with the standard password: paterna
It is possible to loop through an analogue telephone line on the same line parallel to the G.hn signal. To do this,
connect the telephone line and the telephone to the PHONE connecons on the G.hn master and G.hn client.
Produktspecifikationer
Varumärke: | Giga Copper |
Kategori: | Inte kategoriserad |
Modell: | G4202T |
Behöver du hjälp?
Om du behöver hjälp med Giga Copper G4202T ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad Giga Copper Manualer
19 September 2024
19 September 2024
Inte kategoriserad Manualer
- Hard Head
- 4ms
- Carson
- Eurolite
- AOC
- Infiniton
- Lumu
- Sera
- USAopoly
- Sirus
- Linhof
- Concept2
- Heritage Audio
- Grundfos
- Inkbird
Nyaste Inte kategoriserad Manualer
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025