Läs gratis den bruksanvisning för Hager JG463IN (1 sidor) i kategorin vägguttag. Guiden har ansetts hjälpsam av 2 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 1.5 recensioner. Har du en fråga om Hager JG463IN eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/1
Switch-disconnectors / Isolators
2 pole, 3 pole & 3 pole with switched Neutral
User instructions
Ratings to IEC60947-3, BS EN 60947-3 and AS/NZS 3947-3 / IP66
Type
2 pole 3 pole 3 pole + switched Neutral
250V a.c. 50/60HZ 440V a.c. 50/60Hz 440V a.c. 50/60Hz
Utilization category
AC23 A AC23 A AC23 A
Model number
JG220IN
JG232IN
JG240IN
JG263IN
JG320IN
JG332IN
JG340IN
JG420IN
JG432IN
JG440IN
JG463IN
Rated Operational current
20A 32A 40A 63A 20A 32A 40A 20A 32A 40A 63A
Rated insulation voltage
(a.c.)
250V
250V
250V
250V
440V
440V
440V
440V
440V
440V
440V
Rated impulse withstand
voltage
2500V
2500V
2500V
2500V
2500V
2500V
2500V
2500V
2500V
2500V
2500V
Rated short-time withstand
current for 1 sec
240A 384A 480A 756A 240A 384A 480A 240A 384A 480A 756A
Rated short-circuit making
and breaking capacities for
50 ms
240A 384A 480A 756A 240A 384A 480A 240A 384A 480A 756A
Live terminal screws torque
value
2NM .5NM2
2.5NM
2.5NM
2NM 2.5NM 2.5NM
2NM 2.5NM
2.5NM
2.5NM
Neutral terminal screws
torque value
2NM 2NM 2NM 2.5NM
2NM 2NM 2NM 2NM 2.5NM
2.5NM
2.5NM
Earth terminal screws
torque value
2NM 2NM 2NM 2NM 2NM 2NM 2NM 2NM 2NM 2NM 2NM
2.5
6
6
10
2.5
6
6
2.5
6
6
10
Min. size
(sq.mm)
& number
1
1
1
1
1
1
1
1
1
1
1
Conductor
Rigid-
stranded
Max. size
(sq.mm)
4
10
10
16
4
10
10
4
10
10
16
Rated duty
Uninterrupted duty
Note: Use padlock with Ø
Ø
6.00 mm shank when required to lock the unit in theOFF’ position.
1. Disconnect the incoming supply to the unit prior to maintenance/installation of the switch-disconnector.
2. Necessary precautions must be observed to maintain the IP66 rating requirement of the unit.
Hole caps are provided for the unit mounting screws and the cover enclosure mounting screws.
Conduit entry hole caps, reducer gland and conduit mounted on unit during the installation should be taped with thread tape seal
or sealed with silicone sealant to maintain the IP66 rating.
3. Total current and ratings of unit must not be exceeded.
4. Terminal screws must be tightened as per table above.
5. Ensure that the switch actuator is in the ‘OFF position and the switch lever of cover enclosure is positioned in the ‘OFF / ‘O’
position when mounting the cover enclosure.
6. The 7mm hole on the rib adjacent to the switch lever is to provide locking facility of the switch lever in theOFF’ position with
padlo
ck with shank diameter of 6 mm.
enclosure
mounting
hole caps
Ø
25 conduit
entry knock-outs
Ø
25 conduit
entry hole caps
Isolator
mounting
holes
axis of conduit entry caps
Ø
7 locking
hole for switch
lever in 'OFF'
position
87
22
38
50
20mm
CUT-OUT
25mm
CUT-OUT
20mm
CUT-OUT
20mm
CUT-OUT
25mm
CUT-OUT
20mm
CUT-OUT
12,25
170
84
ON
OFF
Dimensions (mm)
Installation instructions