Läs gratis den bruksanvisning för Haier WK-B Airconditioner (14 sidor) i kategorin Luftkonditionering. Guiden har ansetts hjälpsam av 2 personer och har ett genomsnittsbetyg på 4.6 stjärnor baserat på 1.5 recensioner. Har du en fråga om Haier WK-B Airconditioner eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/14

Installation & Maintenance Manual for
Wired Controller Kit WK-B
This wired controller kit WK-A is required when the following wall mount
type of indoor needs to install with wired remote controller YR-E17 or
YR-E16BorYR-E16A or new coming wired controller.
Compatible Model:
AW09EH2VHA, AW12EH2VHA, AW18EH2VHA
Note: WK-B will only work for the wall mount indoors listed above.
1.Installation parts
Installation diagram review
Indoor unit
Kit(WK-B)
Wired remote
12
Step 1: This package includes the following accessories, 1) Base 2) front cover 3) PCB
Board 4) wire cable 3.3 ft
Picture 1.1
1)
Base
3
)PCB board
2
)front cover
4
)
wire cable

Step 2: Choose a proper location to install, e.g. above the top or by the side of the unit
Picture 1.2
Step3: please slide the box front cover up and cross the wire cable from the bottom hole
as shown in picture 1.3. Fix the base with 3 screws on the wall.
Picture 1.3
Step 4: connect the terminals between the wall mount unit and WK-B.
Please use the cable in this box to connect terminal CN2 of the wall mount unit PCB board
and terminal CN5 of WK-B. Pls note using right side of the cable to connect the terminal
as the label instruction on the wire cable, e.g. white side of the cable is plugged into the
terminal CN5 of WK-B.
Step 5: connect the terminals between wired remote and WK-B.
Please connect the right terminal of wired remote and terminal CN1 on WK-B. The
terminal CN1 of WK-B for master unit(unit 0) must connect the wired remote. The picture
1.5 is for reference of attaching.
CN5
CN1
CN
2
S
crew hole

Picture 1.5
Step 6: Please slide the down cover up to complete the installation
2.Maintenance Parts
Now the kit is only available for wired remote controller YR-E16B and YR-E17
and YR-E16A
2.1 Wire Diagram for Single Zone
1 2 3 4
CN1 CN2
CN3
CN4
CN5
SW1
Indoor PCB board
ired controller
AB C AB C
LED3/R
WK-
B
LED2/G LED1/R
LED4/G R:Red
G:Green
Picture 2.1
Remark:
(1) SW1 Default DIP switch: OFF/OFF/OFF/OFF
(2) There is a jumper for both terminal CN3 and CN4.
2.2 Wire Diagram for Multi Zone (Master and Slave)
the wired remote can connect upto16 indoor units at the same time, but each high
wall indoor request 1 PC kit WK-B.
Up to 16 indoor unites can be connected by the wired remote at the same time, but
CN2
Produktspecifikationer
Varumärke: | Haier |
Kategori: | Luftkonditionering |
Modell: | WK-B Airconditioner |
Behöver du hjälp?
Om du behöver hjälp med Haier WK-B Airconditioner ställ en fråga nedan och andra användare kommer att svara dig
Luftkonditionering Haier Manualer
11 Juni 2025
11 Juni 2025
4 Juni 2025
4 Juni 2025
3 April 2025
12 Mars 2025
27 Februari 2025
27 Februari 2025
7 Februari 2025
15 Januari 2025
Luftkonditionering Manualer
- Middle Atlantic
- JHS
- SHE
- Eden
- DEXP
- Siemens
- Columbia Vac
- Telefunken
- Profile
- CyberPower
- Livington
- Create
- D-Let
- Ferroli
- Trisa
Nyaste Luftkonditionering Manualer
18 Juni 2025
18 Juni 2025
18 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
16 Juni 2025