Läs gratis den bruksanvisning för Hayward LifeStar XE (20 sidor) i kategorin Pomp. Guiden har ansetts hjälpsam av 5 personer och har ett genomsnittsbetyg på 4.9 stjärnor baserat på 3 recensioner. Har du en fråga om Hayward LifeStar XE eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/20

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
XE Pump Series
Owner’s Manual
1A3SES16XE
1A3SES17XE
1001440 RevA
Contents
Quick Programming.........2
Pump Warnings...............4
Overview.........................7
Installation......................7
Operation......................10
Troubleshooting............16
Maintenance.................17
Winterization.................17
Sha Seal Change.........18
Replacement Parts........19
Hayward Flow Control
1 Hayward Industrial Drive
Clemmons, NC 27012
Phone (888)-429-4635
www.haywardflowcontrol.com
Status: RELEASED Status Date: 24-Jun-22 Originator: Robert Hills CM: John Parker
Retrieved from Teamcenter on: 29-Jun-2022 15:13 EDT

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
2
SIMPLE SINGLE
BUTTON PROGRAMMING
Button & LED location
Quick Programming Guide
SOLID LED
Daily Schedule Only
SLOW FLASHING
Override Mode Only
QUICK FLASHING
Program Mode Only
# blink indicates intervals
4 second hold
PRESS & HOLD
Program mode /
Save & continue
SHORT PRESS
Override mode /
Choose pump speed
STATUS LIGHT
PUSH BUTTON
3 RAPID FLASHES
Confirms press and hold
successful
3x
OVERRIDE MODE
To ENTER
Press once
To EXIT
Press & Hold
HIGH
3 hours
MEDIUM
3 hours
LOW
3 hours
STOP
No time limit
Press for next
speed Light flashes slowly in
OVERRIDE MODE
4 second hold
START
Back to Daily Schedule
Status: RELEASED Status Date: 24-Jun-22 Originator: Robert Hills CM: John Parker
Retrieved from Teamcenter on: 29-Jun-2022 15:13 EDT

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
3
I
N
T
E
R
V
A
L
1
I
N
T
E
R
V
A
L
3
1
2
h
o
u
r
s
8
h
o
u
r
s
I
N
T
E
R
V
A
L
2
4
h
o
u
r
s
Press & Hold Press & Hold Press & Hold Press & HoldPress one time
DEFAULT DAILY SCHEDULE
PROGRAMMING EXAMPLES
100% 80%
24 hour
1 2 3 4
4 second hold 4 second hold
5
4 second hold 4 second hold
100% for 24 hours
1 2 3 5
4 second hold 4 second hold
4 6
4 second hold
7
4 second hold
80% for 4 hours / 40% for 8 hours / 0% for 12 hours
HOW TO PROGRAM THE DAILY SCHEDULE
Press & Hold
until the light
blinks
Choose
pump speed
INTERVAL 2 INTERVAL 3
8 hours 12 hours
To ENTER
PROGRAM MODE
Choose
pump speed
Back to
Daily Schedule
INTERVAL 1
4 hours
70% 50% 45% 40% 0%
4 hours 8 hours 12 hours
INTERVAL 1 INTERVAL 2 INTERVAL 3
50
50% Pump speed
START: POWER ON
START
50% Pump speed 50% Pump speed
50 50
CHOOSE PUMP SPEEDDAILY SCHEDULE
4 hours
8 hours
12 hours
INTERVAL 1
INTERVAL 2
INTERVAL 3
100
100
100
4 hours
8 hours
12 hours
INTERVAL 1
INTERVAL 2
INTERVAL 3
80
40
0
PRESS FOR NEXT SPEED
1 2 3
Save &
Continue
4 second hold
3x
Save &
Continue
4 second hold
3x
Choose
pump speed
Save &
Continue
4 second hold
3x
4 second hold
3x
Press
two times
Press
six times
Press
seven times
Press &
Hold
Press &
Hold
Press &
Hold
Press &
Hold
The pump will start at 100% speed for 8 minutes to prime
3x 3x 3x 3x
3x 3x 3x 3x
Status: RELEASED Status Date: 24-Jun-22 Originator: Robert Hills CM: John Parker
Retrieved from Teamcenter on: 29-Jun-2022 15:13 EDT
Produktspecifikationer
Varumärke: | Hayward |
Kategori: | Pomp |
Modell: | LifeStar XE |
Behöver du hjälp?
Om du behöver hjälp med Hayward LifeStar XE ställ en fråga nedan och andra användare kommer att svara dig
Pomp Hayward Manualer
2 September 2024
30 Augusti 2024
23 Augusti 2024
21 Augusti 2024
20 Augusti 2024
20 Augusti 2024
20 Augusti 2024
17 Augusti 2024
15 Augusti 2024
14 Augusti 2024
Pomp Manualer
- Technaxx
- Crivit
- Panduit
- Abac
- Heissner
- Fluke
- Gardena
- Maruyama
- Wayne
- Lavorwash
- FIAP
- Zodiac
- Ubbink
- Ozito
- T.I.P.
Nyaste Pomp Manualer
5 April 2025
1 April 2025
1 April 2025
1 April 2025
1 April 2025
1 April 2025
1 April 2025
1 April 2025
1 April 2025
1 April 2025