Heatmiser DS1-EL Bruksanvisning
Sidor 4 Engelska Termostater
Läs bruksanvisningen för Heatmiser DS1-EL gratis online eller ladda ner PDF:en. Bruksanvisningen har visats 57 gånger. Fråga om modellen? Ställ en fråga

Wiring Diagram
The Heatmiser DS1-EL dial type thermostat is designed
specically for electric underoor heating.
This thermostat incorporates the following functions;
• Adjustable Switching Dierential
• Digital LCD
• 230v AC, 13A Switching
Introduction
1
4
Model: DS1-EL
RCD
MAINS SUPPL
Y
LN
MATTING OR WIRE
FlOOR PROBE
DS1-EL
Want More Information?
Call our support team on:
+44 (0)1254 669090
Or view technical specications
directly on our website:
www.heatmiser.com
IN ORDER TO AVOID ANY RISK OF ELECTRIC SHOCK, TURN OFF THE POWER TO THE
HEATING SYSTEM.
This dial thermostat is designed to be surface mounted.
1. Separate the front part of the thermostat by unscrewing securing screws on the
bottom face of the thermostat.
2. Mark 2 hole positions on the wall using the backplate as a positioning template. Drill at
the marked positions and insert a wall plug in to each hole.
3. Terminate the thermostat as per wiring diagram and screw the DS1-EL back plate to the
back box.
4. Reconnect the thermostat front plate and insert the securing screws.
Installation