Läs gratis den bruksanvisning för HeatStar HS9120 (48 sidor) i kategorin Värmare. Guiden har ansetts hjälpsam av 8 personer och har ett genomsnittsbetyg på 3.7 stjärnor baserat på 4.5 recensioner. Har du en fråga om HeatStar HS9120 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/48

OPERATING INSTRUCTIONS AND OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY: Read and follow all
instructions. Place instructions in a safe place for future
reference. Do not allow anyone who has not read these
instructions to assemble, light, adjust or operate the heater.
HEATSTAR High-Intensity Infrared Heaters
MODELS
Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.
If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
WARNING:
— Donotstoreorusegasolineorotherflammablevaporsandliquidsinthevicinityofthisorany
other appliance.
— WHATTODOIFYOUSMELLGAS
• OpenWindows
• DO NOT try to light any appliance.
• DO NOT use electrical switches.
• DO NOTuseanytelephoneinyourhouse.Immediatelycallyourlocalgassupplierfroma
telephoneremotefromtheareaoftheleak.Followthegassupplier'sinstructions.
• DO NOT touch any electrical switch; do not use any phone in your building.
• Installationandservicemustbeperfomedbyaqualifiedinstaller,serviceagencyorthegas
supplier.
• Ifyoucannotreachyourgassupplier,calltheFireDepartment.
Thisisanunventedgas-firedheater.Itusesair(oxygen)fromtheareainwhichitisused.Adequate
combustionandventilationairmustbeprovided.Refertopage5.
ENERCOGROUPINC.,4560W.160THST.,CLEVELAND,OHIO44135•866-447-2194
4000 & 8000 Models 9000 Models
HS4030 HS8070 HS9100
HS4040 HS9080 HS9120
HS8050 HS9090 HS9140
HS8060 HS9100S
WARNING: Improperinstallation,adjustment,alteration,serviceormaintenancecancauseproperty
damage, injury or death. Read the installation, operation, and maintenance instructions thoroughly before
installingorservicingthisheater.Forassistanceoradditionalinformationconsultaqualifiedinstaller,service
agency, or gas supplier.

E2
Enerco Group, Inc. |Gas-Fired Infra-Red Space Heaters Operating Instructions and Owner’s Manual
CONTENTS
GeneralInformation 3 ..........................................................
Clearances ........................................................................ 3
GasSupply 3 ........................................................................
GasPressure 4 .....................................................................
Electrical ........................................................................... 5
Thermostat&Location 5 ......................................................
Ventilation 5 ........................................................................
Operations ........................................................................5
CleaningInformation 5 ........................................................
Thermostat 6 .......................................................................
Troubleshooting 7 ................................................................
Connection diagram for flame rod current
for flame rectification systems ...................................... 8
Replacement parts ............................................................ 9
Control system replacement parts ....................................12
LANGUAGES
ENGLISH
Pages E1 — E16
SPANISH
Pages S1 — S16
FRENCH
Pages F1 — F16
`
WARNING: READTHISOWNER'SMANUAL
CAREFULLYANDCOMPLETELYBEFORETRYINGTO
ASSEMBLE,OPERATE,ORSERVICETHISHEATER.
IMPROPERUSEOFTHISHEATERCANCAUSESERIOUS
INJURYORDEATHFROMBURNS,FIRE,EXPLOSION,
ELECTRICALSHOCK,ANDCARBONMONOXIDE
POISIONING.
WARNING: WHENUSEDWITHOUTFRESH
AIR,HEATERMAYGIVEOFFCARBONMONOXIDE,AN
ODORLESSPOISONOUSGAS.OPENWINDOWANINCH
ORTWOFORFRESHAIRWHENUSINGHEATER.
WARNING: Thisheaterisequippedwitha
PILOTLIGHTSAFETYSYSTEM.DONOTTAMPERWITH
PILOTLIGHTSAFETYSYSTEM.
WARNING: Ifheatershutsoff,donotrelight
untilyouprovidefreshair.Ifheaterkeepsshuttingoff,
haveitserviced.Opendoorfor5minutes.
•Keepburnerandignitioncontrolclean.
•MaintainclearancesasshowninTable1oronheaterratetag.
•DONOTUSEMATCHOROTHERFLAMEFORLEAK
TESTING.
•DONOTEXCEED1/2PSIINLETPRESSURETOHEATER.
WARNING: Fuelsusedinliquefiedpropanegas
appliances, and the products of combustion of such fuel,
canexposeyoutochemicalsincludingbenzene,which
is know to the state of California to cause cancer and
causebirthdefectsorotherreproductiveharm,formore
informationgotowww.P65Warnings.ca.gov
CAUTION:
•Neverconnectgasvalveorthermostattolinevoltage
or a transformer.
•Iftheinfra-redcolorofthegridbecomesdullwhenthe
building furnace is operating, consult gas supplier on
correctgassupplypipingsizes.
•Thisheaterisforindoorinstallationonly!
Carbon Monoxide Poisoning:
Earlysignsofcarbonmonoxidepoisoningresemblethe
flu,withheadaches,dizziness,ornausea.Ifyouhave
thesesigns,theheatermaynotbeworkingproperly.Get
freshairatonce!Haveheaterserviced.Somepeopleare
moreaffectedbycarbonmonoxidethanothers.These
include pregnant women, persons with heart or lung
disease or anemia, those under the influence of alcohol,
and those at high altitudes.
DANGER:
CarbonMonoxidepoisoningmayleadtodeath.
NOTEGasketbindermaterialusedinthisheateras-
semblywilltemporarilyemitanodorand/orvapor.This
conditionwillclearupinapproximately20minutesand
thereafterwillnotreoccur.Refertopage5for
ventilation.
WARNING: THISPRODUCTCANEXPOSE
YOUTOCHEMICALSINCLUDINGLEADANDLEAD
COMPOUNDS,WHICHAREKNOWNTOTHESTATE
OFCALIFORNIATOCAUSECANCERANDBIRTH
DEFECTSOROTHERREPRODUCTIVEHARM.FORMORE
INFORMATIONVISITWWW.P65WARNINGS.CA.GOV

E3 Operating Instructions and Owner’s ManualEnerco Group, Inc. | Gas-Fired Infra-Red Space Heaters
1. GENERAL INFORMATION
a. Yourheatercomesfullyassembledandistestedat
the factory for proper gas and input as stated on
the name plate.
b. Beforeproceedingwiththeinstallation,besuretoin-
spectfordamages.Thefreightcompanythatdelivered
the heater must be notified of any damages prior to
installation.HEATSTARwillsendreplacementpartsfor
damagedpartsonlyafterreceivingasignedinspection
reporttoprovetheliabilityofthefreightcompany.
c. Do not attempt to operate heater with any other gas
than that indicated on the heater name plate.
d. Installationoftheheatermustconformwithlocal
building codes or, in absence of local codes, with
theNationalFuelGasCode,ANSIZ223.1/NFPA54.In
Canada,refertoCAN1-B146.1.
e. Plugged1/8”N.P.T.TestGageConnectionislocated
ontheHeaterGasControloraN.P.T.Connectionis
locatedontheoutsideoftheCastVenturi.
f. Forindoorinstallationonly.Notforuseinresidential
dwellings.NOTE:Aresidentialdwellingisadomicile
intended for use by one or more persons and that
includes one or more areas, such as those used for
cooking,eating,living,sleeping,orasanitaryfacility.A
residential dwelling does not include an attached and
detached garage, workshop, or outdoors.
2. CLEARANCES Minimum clearances to combustibles.
(Refer to Table 1)
Provideadequateclearancetocombustibles,Figure
1,betweencontrolendofheaterforservicing
andminimumontopandsidesforventilationand
combustion air supply.
Aminimumclearanceof8’abovefloorforpublic
garagesinaccordancewithANSI/NFPANo.88most
recenteditionorTable1;whicheverislarger.InCanada
refertoCAN1-B149.1InstallationcodesforGas
burning appliances.
Aminimumclearanceof10’fromthebottomof
heater to top of wing, or engine enclosure, where
aircraftarehoused,and8’abovefloorinotherareas
ofthehangerinaccordancewithANSI/NFPANo.409
mostrecentedition,orTable1;thelargerdimension
ofANSI/NFPANo.409orFigure1istobeused.In
CanadarefertoCCAB149-1-M91.
WARNING: MAINTAINCLEARANCESASSHOWN
INFIGURE1ORONHEATERNAMEPLATE,INGARAGE
INSTALLATIONSWHEREPARKEDVEHICLESARE
DIRECTLYBELOWTHEHEATER.
3. SUSPENSION
Heaterhasfourmountingholes,twooneachend,for
attaching rod or angle iron brackets and shall be safely
andadequatelyfixedinpositionindependentofgas
andelectricsupplylines.RefertoFigures4,5,and7on
pages13and14forrecommendedsuspensions.
4. GAS SUPPLY
Provideadequategassupplyforratedinputofeach
heaterusingAmericanStandardInstallationofgas
pipingandgasappliancesinbuildingANSI/223.1a/
NFPA54Pamphlet,TableC-3showscapacityofpipe
of different diameters and lengths in cubic feet per
hourforNaturalGaswithpressuredropof0.3inches
specifygravityof0.60.ForliquefiedPetroleumGas
(LP)capacityrefertoTableC-3andC-15ofthesame
pamphlet.Forrecommendedheatergasconnection
refertoFigureNo.5,Page15.InCanadarefertoCAN
1-B149.1,andCSAB63.
Ifgaslinesaretobepressuretestedwithcompressed
air,disconnecteachheatertopreventcontroldamage
andcapoutlets.Afterreconnectingallheaters,purge
gas lines of air and check all connections for leaks us-
ing soap solution.
WARNING: DONOTUSEMATCHOROTHER
FLAMEFORLEAKTESTING.
5. PIPING REQUIREMENTS
Allpipinginstalledmustcomplywithlocalcodesandordinances
orwiththeNationalFuelGasCode,ANSIZ223.1(NFPA54),
whichevertakesprecedence.Wheninstallingpiping,thefollowing
requirementsmustbetakenintoconsideration:
• Usenewproperlyreamedblackpipefreefromchips.
• Applyagoodqualitypipecompoundtoallmalethreads
priortoassembly.IfL.P.gasisthefuel,ensurethatpipe
compoundisresistanttoL.P.gas.DONOTUSETEFLON
™ tape.
• Priortoinstallation,applypipecompoundtoallmale
threadsasshowninFigure1
• Malethreadsonpipetobeinstalledintogasvalveshall
meettherequirementsofFigure2.Threadslongerthan
thoseshowninthefiguremaycausegasvalvedistortion
and malfunction.
• Asedimenttrapmeetingthetypicalrequirementsof
Figure3shallbeinstalledinthelinetothegasvalve.
• Adedicatedshutoffvalvefortheheatermustbein-
stalled in the gas supply line.
Figure 1. Pipe Compound Application
USE MODERATE AMOUNT OF PIPE DOPE
LEAVE FIRST 2 THREADS BARE
¾3/4”MAXIMUMTHREADLENGTH
½”BLACKPIPE
TOGASVALVEBODY
Figure 2.
Gas valve
connection
requirements
Produktspecifikationer
Varumärke: | HeatStar |
Kategori: | Värmare |
Modell: | HS9120 |
Behöver du hjälp?
Om du behöver hjälp med HeatStar HS9120 ställ en fråga nedan och andra användare kommer att svara dig
Värmare HeatStar Manualer
29 December 2024
10 September 2024
10 September 2024
8 September 2024
7 September 2024
7 September 2024
7 September 2024
6 September 2024
6 September 2024
6 September 2024
Värmare Manualer
- Quadra-Fire
- Gossmann
- Supra
- Heatstrip
- Zanussi
- Excelair
- Rose LM
- Truma
- Vemer
- Aerian
- Stanley
- Grandhall
- Proline
- Braemar
- Neo
Nyaste Värmare Manualer
5 April 2025
4 April 2025
3 April 2025
2 April 2025
30 Mars 2025
30 Mars 2025
29 Mars 2025
29 Mars 2025
27 Mars 2025
27 Mars 2025