    Läs gratis den bruksanvisning för Hitachi RAS-10CH8 (2 sidor) i kategorin Luftkonditionering. Guiden har ansetts hjälpsam av 8 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 4.5 recensioner. Har du en fråga om Hitachi RAS-10CH8 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
                        Sida 1/2
                    
                    
                    
SPLIT  UNIT  AIR  CONDITIONER
INSTALLATION  MANUAL
      Indoor  Unit Outdoor  Unit
RAS-08CH8/RAS-08CH8(B) RAC-08CH8
    RAS-10CH8/RAS-10CH8(B) RAC-10CH8
    RAS-14CH8/RAS-14CH8(B) RAC-14CH8
● +    –    Screwdriver     ●  Measuring  Tape      ●  Knife
● Saw  ●  ø 65mm Power Drill  ● Hexagonal Wrench
Key  (        4mm)   ●  Wrench  (14,  17,  22mm)    ●
  Gas
Leakage Detector    ● Pipe Cutter   ● Putty   ● Vinyl
Tape       ●  Pliers       ●  Flare  Tool
●Carefully  read  through  the  procedures  of  proper
installation  before  starting  installation  work.
●The sales agent should inform customers regarding
the  correct  operation  of  installation.
Tools  Needed  For  Installation  Work
SAFETY PRECAUTION
●Read  the  safety  precautions  carefully  before  operating  the  unit.
●The  contents  of  this  section  are  vital  to  ensure  safety.  Please  pay  special  attention  to  the  following  sign.
WARNING  ........  Incorrect  methods  of  installation  may  cause  death  or  serious  injury.
CAUTION  .........  Improper  installation  may  result  in  serious  consequence.
Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating
the  unit  as  described  in  the  user’s  guide.
!
!
WARNING
!
CAUTION
!
●A  circuit  breaker  or  fuse  must  be  installed.  Without  a  circuit  breaker  or  fuse  the  danger  of  electric  shock    exists.
A  main  switch  with  a  contact  gap  of  more  than  3mm  has  to  be  installed  in  the  power  supply  line  to  the  outdoor  unit.
●Do  not  install  the  unit  near  a  location  where  there  is  flammable  gas.  The  outdoor  unit  may
catch  fire  if  flammable  gas  leaks  around  it.
●Please  ensure  smooth  flow  of  water  when  installing  the  drain  hose.
●Piping  shall  be  suitable  supported  with  a  maximum  spacing  of  1m  between  the  supports.
●Please request your sales agent or qualified technician to install your unit. Water leakage, short circuit or fire may occur if you
do  the  installation  work  yourself.
●Please  observe  the instructions  stated in the  installation manual during the  process of installation. Improper installation may
cause  water  leakage,  electric  shock  and  fire.
●Make sure that the units are mounted at locations which are able to provide full support to the weight of the units. If not, the
units  may  collapse  and  impose  danger.
●Observe  the  rules  and  regulations  of  the  electrical  installation  and  the  methods  described  in  the  installation  manual  when
dealing  with  the  electrical  work.  Use  power  cables  approved  by  the  authorities  of  your  country.
●Be  sure  to use  the  specified  wire  for  connecting  the  indoor and  outdoor  units.  Please  ensure  that  the  connections  are  tight
after the conductors of the wire are inserted into the terminals. Improper insertion and loose contact may cause over-heating
and  fire.
●Please use the specified components for installation work. Otherwise, the units may collapse or water leakage, electric shock
and  fire  may  occur.
●Be  sure  to  use  the  specified  piping  set  for  R22.  Otherwise,  this  may  result  in  broken  copper  pipes  or  faults.
●When  installing  or  removing  an  air  conditioner,  do  not  allow  air  or  moisture  to  remain  in  the  refrigeration  cycle.  Otherwise,
pressure  in  the  refrigeration  cycle  may  become  abnormally  high  so  that  a  rupture  may  be  caused.
●Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas comes into contact with fire, a poisonous
gas  may  occur.
●After completion of installation work, check to make sure that there is no refrigeration gas leakage. If the refrigerant gas leaks
into  the  room,  coming  into  contact  with  fire  in  the  fan-driven  heater,  space  heater,  etc.,  a  poisonous  gas  may  occur.
●Unauthorized modifications to the air conditioner may be dangerous. If a breakdown occurs please call a qualified air conditioner
technician  or  electrician.  Improper  repairs  may  result  in  water  leakage,  electric  shock  and  fire,  etc.
FOR  SERVICE  PERSONNEL  ONLY
THE CHOICE OF MOUNTING SITE   (Please  note  the  following  matters  and  obtain permission  from  customer  before  installation).
WARNING
!
●The unit should be mounted at stable, non-vibratory location which
can  provide  full  support  to  the  unit.
WARNING
!
●The Outdoor unit must be mounted at a location which can sup-
port  heavy  weight.  Otherwise,  noise  and  vibration  will  increase.
CAUTION
!
●
No nearby heat source and no obstruction near the air outlet is allowed.
●
The  clearance  distances  from  top,  right  and  left  are  specified  in  figure
below.
●
The location must be convenient for water drainage and pipe connection
with  the  Outdoor  unit.
●
To  avoid  interference  from  noise  please  place  the  unit  and  its  remote
controller at least 1m from the radio, television and inverter type fluorescent
lamp.
●
To  avoid  any  error  in  signal  transmission  from  the  remote  controller,
please  put  the  controller  far  away  from  high-frequency  machines  and
high-power  wireless  systems.
●
The  installation  height  of  indoor  unit  must  be  2.3m  or  more.
CAUTION
!
●
Do  not  expose  the  unit  under  direct  sunshine  or  rain.  Besides,  ventilation
must  be  good  and  clear  of  obstruction.
●
The  air  blown  out  of  the  unit  should  not  point  directly  to  animals  or  plants.
●
The clearances of the unit from top, left, right and front are specified in figure
below.  At  least  3  of  the  above  sides  must  be  open  air.
●
Be  sure  that  the  hot  air  blown  out  of  the  unit  and  noise  do  not  disturb  the
neighbourhood.
●
Do  not  install  at  a  location  where  there  is  flammable  gas,  steam,  oil  and
smoke.
●
The  location  must  be  convenient  for  water  drainage.
●
Place  the  Outdoor  unit  and  its  connecting  cord  at  least  1m  away  from  the
antenna or signal line of television, radio or telephone. This is to avoid noise
interference.
●
Do  not  install  outdoor  unit  facing  strong  wind  direction.  It  may damage  the
fan  motor.
INDOOR  UNIT
Names  of  Indoor  Components
Hanger
QtyNo. Item
The  Length  of  Indoor  Unit
Connecting  Cord
Figure  showing  the  Installation
of  Indoor  and  Outdoor  Unit.
OUTDOOR  UNIT
11
Screw  for  holder  of
Remote  Controller
( 3 . 1 x 1 6 )
AAA  Size  Battery
Direction  of  Piping
Dimension  of  Mounting  Stand
of  the  Outdoor  unit
(unit  :  mm)
Holder  for  Remote
Controller There  are  4  directions
allowed,  namely,  horizontally
perpendicular  to  the  unit,
vertically  down  from  right,
horizontally out from right and
horizontally  out  to  left.
Don’t  form  the  piping
downward at the left of the unit.
( 4 . 1 x 3 2 )
Remote  Controller
Purifying  Filter
26
31
42
52
6
7
9
1
0
1
Screw  for  Hanger
Names  of  Outdoor  Components
QtyNo. Item
Drain  Pipe
1
0.8m 1.5m
Connection
Horizontally
perpendicular
to the unit
500
100
35
35
12
225
8
mounting stand
!
CAUTION
•  The  installation  height
of indoor unit must  be
2.3m  or  more.
Bush
2
8
Holder
1
!2
Bush
@
Bush
1
For RAC-08/10CH8 only
For RAC-14CH8 only
For RAC-14CH8 only
above 50mm
above 100mm
above 
0.45m
above 300mm
must not bend
above 100mm
2,300mm or more
12
4
5
3
Maximum pipe length 10m
Minimum pipe length 5m
Plug
6
above 100mm
❈ above 300mm above 200mm
❈ above 100mm
❈ give clearance
as wide as 
possible
above 50mm when
installed on the
ceiling of balcony
above 200mm
●The  difference  in  height  between
the indoor and outdoor unit should
be  kept  max  10m.
●The connecting pipe, no matter big
or  small,  should  all  be  insulated
with  insulation  pipe  and  then
wrapped  with  vinyl  tape.  (The
insulator will deteriorate if it is not
wrapped  with  tape).
The connection of insulated drain hose.
Please use insulated drain hose for the
indoor  piping  (commercial  product).
The  indoor  piping  should  be
insulated  with  the  enclosed
insulation pipe. (If the insulator
is  insufficient,  please  use
commersial  products).
inner diameter   16mmø
Be  sure  to
completely
seal  any
gap  with
putty.
Maximum pipe length 15m
Minimum pipe length 5m
above 200mm
above 700mm
above 200mm
)
above 100mm
above 100mm
give clearance as
wide as possible
above 50mm when
installed on the
ceiling of balcony
(
For RAC-08/10CH8 only
Dimension  of  Mounting  Stand
of  the  Outdoor  unit
(unit  :  mm)
57
12
35
124
500
320 10
20
(10)
340
mounting stand
For RAC-14CH8 only
For RAC-14CH8 only
Installation  of  Hanger,  Wall Penetration and  Installation  of  Protection  Pipe
1
CAUTION
!
●The draining of the water container inside the indoor unit can be done from the left.
Therefore the hanger must be fixed horizontally or slightly tilted towards the side of
drain  hose.  Otherwise,  condensed  water  may  overflow  the  water  container.
Direct  Mounting  On  The  Wall
●Please  use  hidden  beams  in  the  wall  to  hold  the  hanger.
Wall  Penetration  and  Installation  of  Protection  Pipe
●Drill  a    65mm  hole  onø
wall which is slightly tilted
towards the outdoor side.
Drill  the  wall  at  a  small
angle.
●Cut  the  protection  pipe
according  to  the  wall
thickness.
●Empty gap in the sleeve
of protection pipe should
be  completely  sealed
with  putty  to  avoid
dripping of rain water into
the  room.
Procedures  of  Installation  and  Precautions
●Procedures  to  fix  the  hanger.
1. Drill  holes  on  wall. 2. Push  plug  into  the  holes. 3.  Fix  the  hanger  on  wall
(As  shown  below) (As  shown  below) with  4.1  x  32  screw
(As shown in figure below)
●Procedures  to  fix  the  holder  of  remote  control.
1. Drill  holes  on  wall. 2. Push  plug  into  the  holes.
(As  shown  below) (As  shown  below)
      Installation  of  the  Indoor  Unit2
VERTICALLY  DOWNWARD  PIPING
    Preparation
●Connect  connecting  cord.
●Pull  out  the  pipe,  connecting  cord  and  drain  hose.
    Installation
●The  upper  part  of  the  Indoor  unit  is  hanged  on  the  hanger.
●The projection at the lower part of the Indoor unit is hooked onto the hanger.
Please  pull  the  lower  part  of
the  Indoor  unit  outwards  to
check  if  the  unit  is  hooked
onto  the  hanger.  Improper
installation  may  cause
vibration  and  noise.
!
CAUTION
HORIZONTAL  PIPING
    Preparation
Change  of  Drain  Hose  and  Installation  Procedures.
●
Exchange  the  location  of  drain  hose  and drain  cap  during  horizontal  piping  as  shown in
figure below. Be sure to plug in the drain hose until the insulating material folds upon itself.
●Please  use  pliers  to  pull  out  the  drain  cap.
(This is an easier way to remove the drain cap).
INSTALLATION  OF  REFRIGERATING  PIPES  AFTER  CONNECTION
●The refrigerating pipes should be adjusted to fit into
the  hole  on  the  wall  and  then  ready  for  further
connection.
●The terminals of 2 connected pipes must be covered
with insulator used for terminal connection. Then the
pipes  are  wrapped  with  insulation  pipe.
●Connect the connecting cord after removing electrical
cover. (Refer to “CONNECTION OF POWER CORD”)
●After  adjustment,  fit  the  connecting  cord  and  pipes
into  the  space  available  under  the  indoor  unit.  Use
holder  to  hold  them  tight.
!
CAUTION
●
The  rubber  strap  used  for
fixing  the  insulator  should
not be tied with great force.
Otherwise, this will damage
heat insulation and causes
water  condensation.
●Holder  can  be  attached  at  the  either  of  2  places.
Please  select  the  easier  position.
THE  CONNECTION  OF  REFRIGERATING  PIPE  DURING  THE
INSTALLATION  OF  INDOOR  UNIT
Preparation  To  Install  Refrigerating  Pipes
!
CAUTION
●Please fix in the plastic core
after flaring to avoid plastic
chips  entering  the  pipes.
CAUTION
!
You are free to choose the side (left or right) for the installation of drain
hose. Please ensure  the  smooth flow of condensed water of the Indoor
unit  during  installation.  (Carelessness  may  result  in  water  leakage.)
!
CAUTION
Be  sure  that  the
drain  hose  is  not
loosely connected
or  bend.
Be sure that the wire is not
in  contact  with  any  metal
in the wall. Please use the
protection  pipe  as  wire
passing through the hollow
part  of  the  wall  so  as  to
prevent  the  possibility  of
damaged  by  mouse.
Unless it seals completely,
any air with high humidity
flows  from  outdoor  and
any  dew  may  drop.
!
WARNING
●The  refrigerating  pipes  and  connecting  cord
transform  and  are  attached.
●The  end  of  the  refrigerating  pipes  are  at  locations
marked  with    symbol.“ ”   
      Installation  of  Drain  Hose
3
    Installation
Hang the Indoor unit onto the hanger. Use the temporary stand
at  the  back  of  the  Indoor  unit  to  push  its  lower  part  15cm
forwards.
●Place  the  drain  hose  through  the  hole  on  the  wall.
●Wrap  the  refrigerating  pipes  with  insulation  pipe  after
connecting  refrigerating  pipe.
●Connect the connecting cord after removing electrical cover.
(Refer  to  Connection  of  Power  Cord“ ”)
●After adjustment, the connecting cord and refrigerating pipes
are  placed  into  the  space  available  under  the  Indoor  unit.
●The  projection  of  Indoor  unit  must  hook  to  the  hanger.
INDOOR  UNIT
<
IA321: A 
>
HOW  TO  REMOVE  INDOOR  UNIT
●Push  up  the  (PUSH)  sections  at  the
bottom  of  the  indoor  unit  and  pull  the
bottom  plate  towards  you.  Then  the
claws are released from the stationary
plate.
(The (PUSH) sections are indicated by
2  arrows  in  the  right  figure)
Sleeve of
protection
pipe
WALL
Protection
pipe
Seal with
putty
Seal with
putty
2 ~ 5mm
OutdoorIndoor
Connecting cords, pipe and
drain hose must be laid
together with Vinyl tape.
Lift the body
of the unit
upwards and
then force it
downwards.
Hanger
Refrigerating
Pipe
Protection
Pipe Drain Hose Connecting 
Cord
Hanger
1
Projection
2
[Push] mark positions
!
CAUTION Condensed  water  may  leak  out  if  not  inserted  properly.
HORIZONTAL  &  DOWNWARD  PIPING  –  MAKING  OPENINGS
●During  horizontal  or  downward  piping,  use  a  knife  to  cut
openings as  shown in figure.  Then  smoothen the  edges  of
openings  with  a  file.
●Turn  the  piping  while  holding  down  the  lower
portion  of  pipe-support  by  hand.
Drain hoseDrain cap
Drain cap
Please insert
until here
Drain hose
Please insert
until here
Pipe 
support
Pull up the pipe after
bending downward
Openings
Pipe
Connecting
cord
Drain hose
Insulation pipe (must be wrapped with
vinyl tape at every 120mm).
8   Holder   
Pipe Rubber strap tied with great force
below
5mm
Please bend at a small
radius to form an arc
0.85m
about 15cm
Hook
Projection
Protection pipe
Connecting cord
Holder Connected section
Drain hose
HITAC H
I
Heat insulation pipe
Connecting
cord
Refrigerating  pipe
Bending
upwards
Condensed
water pond
Ditch Condensed
water pond
Pull  this  to  the  front
during  the  connection
of refrigerating pipes to
ease  task.
125mm
45mm
200mm
60mm
80mm
780mm
125mm
280mm
45mm
115mm
450mm
Level
Hanger
Hole for pipe
Weight
Mark
Line
Please use more
than 4 screws.
Screw for Hanger
Produktspecifikationer
| Varumärke: | Hitachi | 
| Kategori: | Luftkonditionering | 
| Modell: | RAS-10CH8 | 
Behöver du hjälp?
Om du behöver hjälp med Hitachi RAS-10CH8 ställ en fråga nedan och andra användare kommer att svara dig
Luftkonditionering Hitachi Manualer
                        
                         19 Februari 2025
                        
                    
                                                            
                        
                         30 September 2024
                        
                    
                                                            
                        
                         23 September 2024
                        
                    
                                                            
                        
                         22 September 2024
                        
                    
                                                            
                        
                         22 September 2024
                        
                    
                                                            
                        
                         22 September 2024
                        
                    
                                                            
                        
                         22 September 2024
                        
                    
                                                            
                        
                         22 September 2024
                        
                    
                                                            
                        
                         22 September 2024
                        
                    
                                                            
                        
                         22 September 2024
                        
                    
                                                            Luftkonditionering Manualer
- Cecotec
- Theben
- Brandt
- Guzzanti
- Bavaria
- Gutfels
- ETA
- Point
- Mabe
- Céliera
- InAlto
- Mestic
- Andrews
- Royal Sovereign
- Qlima
Nyaste Luftkonditionering Manualer
                        
                         20 Oktober 2025
                        
                    
                                                            
                        
                         20 Oktober 2025
                        
                    
                                                            
                        
                         20 Oktober 2025
                        
                    
                                                            
                        
                         19 Oktober 2025
                        
                    
                                                            
                        
                         17 Oktober 2025
                        
                    
                                                            
                        
                         17 Oktober 2025
                        
                    
                                                            
                        
                         16 Oktober 2025
                        
                    
                                                            
                        
                         16 Oktober 2025
                        
                    
                                                            
                        
                         16 Oktober 2025
                        
                    
                                                            
                        
                         13 Oktober 2025