Portable Evaporative Air Cooler
OWNER’S MANUAL
Read and save these instructions before use
Voltage rating: 220 - 240V~50Hz
110V~60Hz
Power rating: 230W
For product enquiry or support contact :
e-mail: info@honeywellaircoolers.com
Made in China.
Model: CL20AE
CUST OMER CARE :
www.honeywellaircoolers.com
This page is intentionally left blank
SECTION PAGE
1. THANK YOU .........................................................................................................
2. USER TIPS ...........................................................................................................
3. SAFETY RULES ...................................................................................................
4. PARTS DESCRIPTION ........................................................................................
5. USE & OPERATION .............................................................................................
6. CLEANING & MAINTENANCE .............................................................................
7. TROUBLESHOOTING GUIDE .............................................................................
8. TECHNICAL SPECIFICATIONS ...........................................................................
9. ELECTRICAL WIRING DIAGRAM ........................................................................
2
3
5
7
8
14
16
18
18
INDEX
1
Read all instructions carefully before setting up and operating the unit, and please keep
this instruction manual for future reference. This manual is designed to provide you with
important information needed to setup, operate, maintain, and troubleshoot your cooler.
Failure to follow these instructions may damage and/or impair its operation and void the
warranty.
Fill Water ......................................................... .................... ...............
Function Buttons .................................................................................................
Room Cooling and Humidifying ...........................................................................
Remote Control ...................................................................................................
.... ............ 13
Control Panel ..................................................................................................... 8
9
11
12
THANK YOU!
THANK YOU
2
Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler. For optimum
cooling performance from your unit, fill the water tank with water & ice (if available) to increase its
cooling power. The unit should be positioned in a location that will create a 'flow through' air effect.
The greatest cooling effect will be felt if the unit is operated in a partly opened doorway or window.
Please read these instructions carefully.
USER TIPS
3
Pump
Water
Honeycomb Cooling Media
Evaporative Air Cooling Mechanism
Warm and
dry air
Cold and
humid air
COOL ~ EFFICIENT ~ NATURAL
Evaporative air cooling is the natural way of cooling, similar to a breeze blowing across a lake. This
breeze drops the temperature and has a relaxing cooling effect.
The evaporative air cooler cools the air by means of the evaporation of water. When water
evaporates into the air, the result is a mixture of air and water molecules. This chemical change
requires heat which is taken from the water molecules, resulting in cooler air propelled from the
unit.
NOTE
4
The recommended maximum relative humidity level is 60% or
less, which allows a noticeable temperature decrease. The
temperature decrease will be greater in drier climates because
higher evaporation occurs when the humidity is low.
The evaporative air cooler should not be used in enclosed
spaces. It must be kept level and there must be water in the
water tank. The room should have doors and windows opened
to allow free air flow. The evaporative air cooler works best
when placed near an open window, so that outside air is drawn
into the evaporative air cooler, the air circulates in the room,
then exits via the door. The maximum cooling effect is felt
when a person is in the flow of air coming out of the evaporative
air cooler.
The evaporative air cooler can also be used to humidify dry air
during cool weather. To be used for humidification the
windows and doors should be closed to allow the humidified
air to accumulate. The evaporative air cooler is not an air
conditioner as it does not use a compressor or refrigerant gas.
It should not be expected to cool as efficiently as a refrigerated
air conditioner.
When the product is used for the first time the Honeycomb
cooling media will have an odour which will dissipate in a week
or so of initial use.
Room with open windows & door
Room with closed windows & door
USER TIPS
The recommended maximum relative humidity level is 60% or
less, which allows a noticeable temperature decrease. The
temperature decrease will be greater in drier climates because
higher evaporation occurs when the humidity is low.
The evaporative air cooler should not be used in enclosed
spaces. It must be kept level and there must be water in the
water tank. The room should have doors and windows opened
to allow free air flow. The evaporative air cooler works best
when placed near an open window, so that outside air is drawn
into the evaporative air cooler, the air circulates in the room,
then exits via the door. The maximum cooling effect is felt
when a person is in the flow of air coming out of the evaporative
air cooler.
The evaporative air cooler can also be used to humidify dry air
during cool weather. To be used for humidification the
windows and doors should be closed to allow the humidified
air to accumulate. The evaporative air cooler is not an air
conditioner as it does not use a compressor or refrigerant gas.
It should not be expected to cool as efficiently as a refrigerated
air conditioner.
When the product is used for the first time the Honeycomb
cooling media will have an odour which will dissipate in a week
or so of initial use.
Room with open windows & door
Room with closed windows & door
READ AND SAVE THESE INSTRUCTIONS:
SAFETY RULES
220-240 Volt AC, 50Hz
SHOCK HAZARD
WATER LEVEL INDICATOR
5
When using electrical appliances, basic safety precautions should always be followed:
Always unplug the product before refilling the water tank.
Always unplug the appliance from the power source before
cleaning, servicing or relocating the unit.
Remove the power cord from the electrical receptacle by
grasping and pulling on the power cord plug-end only, never
pull the cord.
DO NOT use the product in areas where gasoline, paint or
other flammable goods and objects are stored.
When using the ''COOL'' setting, please check the water tank
to ensure it is full. Operation of this unit on the ''COOL'' setting
with an empty tank may result in damage to the water pump.
DO NOT run power cord under carpeting, or cover it with
rugs or runners. Keep the cord away from areas where it
may be tripped over.
Your unit runs on 220/127 Volt AC, 60 Hz current. Check the
household voltage to ensure it matches the appliance's rate
specification.
Before operating the product remove it from its packaging
and check it is in good condition.
DO NOToperate any product with a damaged cord or plug.
We recommend not using an extension cord with this
appliance.
SAFETY RULES
FLOOR LEVEL
6
• DO NOT attempt to repair or adjust any electrical or
mechanical functions of the cooler, as this may void the
warranty.
• DO NOT cover the air inlet or outlet on the appliance as this
may cause motor damage.
• DO NOT insert or allow objects to enter any ventilation or
exhaust opening as this may damage the product and could
cause an electrical shock or fire.
• DO NOT operate with the honeycomb media removed as
this will overload and damage the motor.
• DO NOT leave the appliance operating unattended for any
extended period of time.
• DO NOT let children play with this appliance, packaging or
plastic bags.
• If the unit is damaged or malfunctions, do not continue to
operate it. Refer to the troubleshooting section and /or seek
professional advice.
• Place the unit on a level floor.
• This product is not intended for use in wet or damp locations.
• Never locate the product where it may fall into a bathtub or
other water container. DO NOT use in bathrooms or
outdoors.
• When the unit is not in use always store it in a dry area.
• This appliance is not intended for use by persons (including
children or elderly) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
• Always grip the side handles to move the unit.
ON/OFF
TIME
SPEED
SWING
COOL
MODE
CONTROL PANEL
SPEED TIMER
MODE
SWING
High
Mid
Low
Sleep
Cool
8hr 7hr
6hr
5hr
4hr
3hr
2hr
1hr
POWER
Speed Control
Swing Control
Power Button
Timer Control
Mode Button
USE & OPERATION
8
9
FUNCTION BUTTONS
USE & OPERATION
POWER
SPEED
High
Mid
Low
Sleep
MODE
Cool
SWING
High Medium Low Sleep
Sleep setting is for comfort during the night.
POWER
Press the POWER button to turn the unit on. To turn the unit
off, press the button again. The cooler will start automatically
at medium speed. After a few seconds the speed will switch to
low.
SPEED
Press the SPEED button repeatedly and the speed will
change. The indicator light will show the selected speed.
MODE / COOL
To begin cooling the desired area, press the MODE button.
The indicator light will come on and the water pump will
operate. You will feel the cooler air after the honeycomb
media is completely wet.
USE & OPERATION
TIMER
8hr 7hr
6hr
5hr
4hr
3hr
2hr
1hr
TIMER
Press the TIMER button until the indicator light moves to your
desired time. Once the set time has passed, the unit will
automatically shut off. The Timer function allows you to
program the unit for up to 8 hours of use.
LOUVERS MOVEMENT
SWING
Press the SWING button. The indicator light will come on and
the louvers will begin to move from right to left automatically.
Manually adjust the horizontal louvers to change vertical
airflow.
10
11
USE & OPERATION
ROOM COOLING AND HUMIDIFYING
When the water regulator is set to MIN, the water pump
distributes a minimal amount of water to the honeycomb
media. This results in less water evaporation and reduces
cooling effect. Thus, reducing the humidity inside the room.
When the water regulator is set to MAX, the water pump
distributes the maximum amount of water to the honeycomb
media. This results in maximum water evaporation and the
cooling performance improves. Thus, increasing the humidity
inside the room.
Water Regulator is located inside the ice loading compartment.
Regulator knob can be rotated using your own hands.
NOTE
Water Regulator
MIN
MAX
12
USE & OPERATION
REMOTE CONTROL
Power: On / Off
Speed: Speed: Low / Medium / High / Sleep
Mode: Controls cooling or fan option
Swing: Controls the motion of the louvers
Timer:
Note : Remote control and holder are packed inside the top
ice loading compartment, during delivery.
Controls timer function for automatic shut off
NOTE
• Please open the battery compartment at the back of the
remote control and insert two new AAA dry cell batteries.
Care must be taken to insert the batteries according to the
correct polarity (+ / –) markings shown inside the battery
compartment.
• Always point the remote control signal transmitter toward the
unit when operating.
• Make sure that the signal path is not obstructed.
• Remove the batteries if the unit is not going to be used for an
extended period of time.
• Do not drop the remote control.
MODE
SPEED
TIMER SWING
Evaporative Air Cooler
ON/OF
13
USE & OPERATION
FILL WATER
CAUTION
Open the Water Fill Door located below the Remote Control
Holder on the unit. The water tank of the unit holds up to 20 litres
of water.
Water level display window is located on the front of the unit.
Refill the water tank when water level is low. Do not fill water
above the Max water level mark. Check water level in the tank
before running the ''COOL'' function. Please be sure water in
the tank is always above minimum water level mark. Running
the unit with inadequate water may cause pump failure. If ice is
available you may add ice in the top compartment to enhance
the cooling performance.
Unplug from power when refilling.
Water Fill Door
Ice Loading Compartment

Produktspecifikationer

Varumärke: Honeywell
Kategori: Luftkonditionering
Modell: CL201AE

Behöver du hjälp?

Om du behöver hjälp med Honeywell CL201AE ställ en fråga nedan och andra användare kommer att svara dig




Luftkonditionering Honeywell Manualer

Luftkonditionering Manualer

Nyaste Luftkonditionering Manualer