Läs gratis den bruksanvisning för IFM AL1332 (134 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 3 personer och har ett genomsnittsbetyg på 4.7 stjärnor baserat på 2 recensioner. Har du en fråga om IFM AL1332 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/134
>
>
80284134 / 02 10 / 2021
Operating instructions
IO-Link master with EtherCAT interface
DataLine
8 ports
IP 65 / IP 66 / IP 67
AL1332
Firmware: 3.1.x
English
IO-Link master with EtherCAT interface DataLine 8 ports IP 65 / IP 66 / IP 67
2
Contents
1 Preliminary note 5
1.1 Legal and copyright information ........................................................................................... 5
1.2 Purpose of the document ..................................................................................................... 5
1.3 Explanation of Symbols ....................................................................................................... 5
1.4 Change history ..................................................................................................................... 6
2 Safety instructions 7
2.1 General ................................................................................................................................ 7
2.2 Required background knowledge ........................................................................................ 7
2.3 Safety symbols on the device .............................................................................................. 7
2.4 IT security ............................................................................................................................. 8
3 Intended use 9
4 Function 10
4.1 Communication, parameter setting, evaluation ................................................................. 11
4.1.1 - IO Link........................................................................................................................................ 11
4.1.2 EtherCAT .................................................................................................................................... 11
4.1.3 Internet of Things (IoT) ............................................................................................................... 11
4.1.4 Security mode ............................................................................................................................ 11
4.1.5 Parameter setting ....................................................................................................................... 11
4.1.6 Visual indication .........................................................................................................................12
4.2 Digital inputs ....................................................................................................................... 12
4.3 -Link supply IO .................................................................................................................... 12
5 Mounting 13
5.1 Mount the device ................................................................................................................ 13
6 Electrical connection 14
6.1 Notes .................................................................................................................................. 14
6.2 Connecting the EtherCAT ports ......................................................................................... 15
6.3 Connecting the IoT port ..................................................................................................... 15
6.4 -Link ports IO ....................................................................................................................... 16
6.4.1 Connecting IO-Link devices for Class A operation ..................................................................... 16
6.4.2 Connecting IO-Link devices for Class B operation ..................................................................... 17
6.5 Connecting the device ....................................................................................................... 18
7 Operating and display elemen ts 19
7.1 Overview ............................................................................................................................ 19
7.2 LED indicators .................................................................................................................... 20
7.2.1 Status LEDs ............................................................................................................................... 20
7.2.2 EtherCAT interface ..................................................................................................................... 20
7.2.3 IoT port ....................................................................................................................................... 21
7.2.4 Voltage supply ............................................................................................................................ 21
7.2.5 -Link Ports (Class A) IO ............................................................................................................... 21
IO-Link master with EtherCAT interface DataLine 8 ports IP 65 / IP 66 / IP 67
3
8 Set- up 22
9 Configuration 23
9.1 LR DEVICE ........................................................................................................................ 24
9.1.1 Remarks ..................................................................................................................................... 25
9.1.2 IoT: Congure IP settings ........................................................................................................... 25
9.1.3 IoT: Congure security mode ..................................................................................................... 26
9.1.4 IoT: Conguring access rights .................................................................................................... 27
9.1.5 IoT: Congure the interface to LR AGENT or LR SMARTOBSERVER ...................................... 28
9.1.6 Fieldbus: Congure EtherCAT interface ..................................................................................... 28
9.1.7 -Link ports: Activate data transfer to LR AGENT or LR SMARTOBSERVER IO ......................... 29
9.1.8 -Link ports: Congure operating mode IO ....................................................................................30
9.1.9 -Link ports: Set the device validation and data stora IO ge .......................................................... 31
9.1.10 Info: Show device information .................................................................................................... 32
9.1.11 Firmware: Reset device to factory settings ................................................................................. 32
9.1.12 Firmware: Reboot the device ...................................................................................................... 32
9.1.13 Congure IO-Link devices .......................................................................................................... 33
9.2 ifm IoT Core ....................................................................................................................... 34
9.2.1 Programmers' notes ................................................................................................................... 35
9.2.2 First steps ................................................................................................................................... 39
9.2.3 General functions ....................................................................................................................... 39
9.2.4 IoT: Conguring access rights .................................................................................................... 43
9.2.5 IoT: Conguring IP settings ........................................................................................................ 43
9.2.6 IoT: Conguring security mode ................................................................................................... 44
9.2.7 Fieldbus: Conguring the eldbus interface ................................................................................ 46
9.2.8 -Link ports: Setting the operating mode of pin 4 (US) IO ............................................................. 46
9.2.9 -Link ports: Conguring device validation and data storage IO ................................................... 47
9.2.10 -Link ports: Conguring data transfer to LR AGENT or LR SMARTOBSERVER IO .................... 49
9.2.11 -Link ports: Reading / writing process data IO ............................................................................. 49
9.2.12 -Link ports: Indicating port events IO ........................................................................................... 52
9.2.13 -Link devices: Accessing parameters IO ..................................................................................... 52
9.2.14 -Link devices: Reading an writing device information IO ............................................................. 54
9.2.15 -Link devices: Indicating IO-Link events IO ................................................................................. 54
9.2.16 Gateway: Resetting, rebooting and localising the device ........................................................... 54
9.2.17 Gateway: Reading device information ........................................................................................ 55
9.2.18 Gateway: Reading status and diagnostic information ................................................................. 55
9.2.19 Gateway: Updating the rmware ................................................................................................ 56
9.2.20 Gateway: Setting the application tag .......................................................................................... 57
9.2.21 Subscribing to notications ......................................................................................................... 58
9.2.22 Using Web Socket ...................................................................................................................... 62
9.2.23 MQTT support ............................................................................................................................ 64
9.2.24 Using the IoT-Core Visualizer ..................................................................................................... 68
9.3 EtherCAT ........................................................................................................................... 75
9.3.1 Install ESI le .............................................................................................................................. 75
9.3.2 Integrate the IO-Link master into the TwinCAT project ............................................................... 75
9.3.3 Congure IO-Link master ........................................................................................................... 76
9.3.4 Congure IO-Link ports .............................................................................................................. 76
9.3.5 Congure cyclic process data ..................................................................................................... 77
9.3.6 Read and write cyclic process data ............................................................................................ 78
9.3.7 Read diagnostic and status information .....................................................................................79
9.3.8 Read IO-Link events ................................................................................................................... 80
9.3.9 Congure IO-Link devices .......................................................................................................... 80
9.3.10 EtherCAT: Programmers' notes .................................................................................................. 81

Produktspecifikationer

Varumärke: IFM
Kategori: Inte kategoriserad
Modell: AL1332

Behöver du hjälp?

Om du behöver hjälp med IFM AL1332 ställ en fråga nedan och andra användare kommer att svara dig