Sida 1/3

Installation Instructions
Welding adapter
G1 / G¾
706013/02 08/2017
UK
UK
UK
UK
UK

2
A
BB
1 2
A: Groove for the O-ring (E30072 only); B: Marking for alignment
Order no. Type Material Pressure rating *
E30009 G¾ - Ø 50mm stainless steel (316S12) 25 bar
E30013 G1 - Ø 50mm stainless steel (316S12) 150 bar
E30060 G1 - Ø 50mm steel (1.0570) 50 bar
E30072 G1 - Ø 50mm stainless steel (316S12) 150 bar
* for the connection sensor - adapter
E30072 is supplied with a Viton O-ring and an EPDM O-ring
Note
• The welding operation must be carried out by authorised personnel.
• It must be carried out carefully and according to state-of-the-art technology.
• During welding and the following cooling phase, neither sensor nor O-ring must
be in place.
• The surfaces must be free from soiling of any kind.
• Welding tools must be suitable for the adapter and wall material.
Preparations
• Bore a hole in the pipe or housing wall with the outside diameter of the adapter
(max. oversize: 0.2 mm).
• If possible, screw a welding mandrel into the adapter
(order no. E30435 for G1 thread, order no. E30071 for G3/4 thread).

3
UK
Welding operation
3 4
►Align the adapter: Turn the marking to the position provided for the connector /
display of the screwed sensor (see figure 2).
►Fix the adapter at several points with sufficient holding force, apply the fixing
points at equal distance opposite each other (see figure 3).
►Apply the welding seams between the fixing points opposite each other (see
figure 4). Ensure sufficient intervals between the individual sections (cooling
phases to avoid glowing through / warping of the adapter due to overheating).
The power of the welding device must be adapted to the thickness of the wall.
After welding
►Let the adapter cool down.
►Clean the thread from welding residues.
►Grease the thread with lubricating paste.
The paste must be suitable and approved for the application and compatible
with the elastomers used.
►For the adapter E30072, place one of the supplied O-rings in the groove of the
adapter (Viton or EPDM O-ring, depending on the fluid). It must snap flush into
the groove over its whole circumference (see figure 1).
Note: If the sensor can only be screwed into the thread with great resistance,
apply no force.
If it is not possible to rectify the thread, remove the adapter and weld in a new one.
Produktspecifikationer
Varumärke: | IFM |
Kategori: | Inte kategoriserad |
Modell: | E30013 |
Behöver du hjälp?
Om du behöver hjälp med IFM E30013 ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad IFM Manualer

8 April 2025

8 April 2025

8 April 2025

2 April 2025

2 April 2025

1 April 2025

1 April 2025

1 April 2025

31 Mars 2025

12 Mars 2025
Inte kategoriserad Manualer
- Inte kategoriserad Westcott
- Inte kategoriserad Baby Brezza
- Inte kategoriserad Guide
- Inte kategoriserad Dream
- Inte kategoriserad Gemini
- Inte kategoriserad Bome
- Inte kategoriserad Hertz
- Inte kategoriserad Parrot
- Inte kategoriserad Kitchen Brains
- Inte kategoriserad WilTec
- Inte kategoriserad Santos
- Inte kategoriserad Ventev
- Inte kategoriserad SafeMi
- Inte kategoriserad Yphix
- Inte kategoriserad Jamo
Nyaste Inte kategoriserad Manualer

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025