Installation Instructions
Adapter
E30116
706015/00 05/2011
UK
ifm electronic gmbh • Friedrichstr. 1 • 45128 Essen • Germany
http://www.ifm.com • e-mail: info@ifm.com
2
Mounting sensor - adapter
B
I
A
1 2 3 + 4
Slightly grease the threads and sealing areas of the sensor and adapter with
the lubricating paste (A).
The paste must be suitable and approved for the application and compatible
with the elastomers used.
Screw the sensor into the adapter until it is hand-tight.
Clamp sensor and adapter into a clamping device (B).
Tighten the clamping device only slightly so that the adapter does not warp.
Tighten the sensor using a spanner (tightening torque: 20 Nm).