Läs gratis den bruksanvisning för IFM E30432 (3 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 2 personer och har ett genomsnittsbetyg på 4.6 stjärnor baserat på 1.5 recensioner. Har du en fråga om IFM E30432 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/3
Installation Instructions
Accessory cover for filter system
for pressure sensors type PN
E30432
80261965 / 00 12 / 2016
UK
UK
UK
UK
UK
2
A
B
4,5
8
4,5
10
10
(2-2,5 Nm)
360°
3
2
1
4
3
The accessory cover for filter system is only suitable for PN type pressure
sensors (sensors with setting via 3 pushbuttons).
Contents
1. Sealing ring (FKM)
2. Plug insert (PEEK)
3. Filter cover (1.4404/316L, internal sealing rings: FKM)
4. Tube adapter (stainless steel, sealing ring: PA6)
5. Tube adapter with tube fitting (POM, brass, stainless steel, sealing ring: steel,
NBR coated).
6. Tube (polyamide, harmless to the German Food and Consumer Goods Law
para 5 section 1 clause 1 and clause 5)
7. Screw plug (stainless steel, sealing ring: PA6)
Installation
Slide the sealing ring (1) over the M12 connection of the unit.
Insert the plug insert (2) into the M12 connection of the unit.
Filter cover (3):part A can be turned against part B
Screw the filter cover (3) on the M12 connection of the unit (recommended
tightening torque: 2 - 2.5 Nm).
Turn the opening of the filter cover (3), part (A) to an area protected from
media.Screw the adapter (4) or (5) into the thread connection of the filter cover
(3).Attach the tube (6) to the adapter and lay the free tube end in a dry area
protected from media.
Alternative
Close the thread connection of the filter cover (3) using a screw plug (7).
When using the screw plug (7) there is no pressure compensation any
more of the measuring cell.
This measure is only recommended if a small measurement error is acceptable.
The following factors lead to a measurement deviation:
Fluctuation of the atmospheric pressure
Fluctuation of the internal device pressure in case of a temperature change
(Δ 10 K 30 mbar).