IFM PD3223 Bruksanvisning
IFM
Inte kategoriserad
PD3223
Läs gratis den bruksanvisning för IFM PD3223 (5 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 7 personer och har ett genomsnittsbetyg på 3.8 stjärnor baserat på 4 recensioner. Har du en fråga om IFM PD3223 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/5

Installation Instructions
Electronic pressure sensor
PD3223
704905 / 00 08 / 2010
UK

2
1 Safety instructions
• Please read the product description prior to installing the unit.
• Ensure that the product is suitable for your application without any restrictions.
• If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property may occur.
• Please check for all applications that the product materials (see Technical data)
are compatible with the media to be measured.
For units with cULus approval and the scope of validity cULus:
The device shall be supplied from an isolating transformer having a secondary
Listed fuse rated as noted in the following table.
Overcurrent protection
Control-circuit wire size Maximum protective device rating
Ampere
AWG (mm2)
26 (0.13) 1
24 (0.20) 2
22 (0.32) 3
20 (0.52) 5
18 (0.82) 7
16 (1.3) 10
The Sensor shall be connected only by using any R/C (CYJV2) cord, having
suitable ratings.
Contents
1 Safety instructions ........................................................................ 2
2 Function and features ................................................................... 3
2.1 Applications .............................................................................. 3
Type of pressure: relative pressure ................................................ 3
3 Installation .................................................................................... 4
4 Electrical connection..................................................................... 4
5 Scale drawing ............................................................................... 5
6 Technical data ............................................................................... 5

3
UK
2 Function and features
The pressure sensor detects the system pressure and converts it into an analog
output signal.
• 4 ... 20 mA
2.1 Applications
• Liquids and gases
• Cannot be used for oils
• Type of pressure: relative pressure
Order no. Measuring range Permissible
overload pressure
Bursting
pressure
bar PSI bar PSI bar PSI
PD3223 0...25 0...363 150 2 175 350 5 075
MPa = bar ÷ 10 / kPa = bar × 100
Static and dynamic overpressures exceeding the indicated overload pres-
sure are to be avoided by taking appropriate measures.
The indicated bursting pressure must not be exceeded. Even if the bursting
pressure is exceeded only for a short time, the unit can be destroyed.
NOTE: Risk of injury!
3 Installation
Before mounting and removing the sensor, make sure that no pressure is
applied to the system.
► Insert the unit in a ¼‘‘ NPT process connection.
► Tighten firmly.
Produktspecifikationer
Varumärke: | IFM |
Kategori: | Inte kategoriserad |
Modell: | PD3223 |
Behöver du hjälp?
Om du behöver hjälp med IFM PD3223 ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad IFM Manualer
8 April 2025
8 April 2025
8 April 2025
2 April 2025
2 April 2025
1 April 2025
1 April 2025
1 April 2025
31 Mars 2025
12 Mars 2025
Inte kategoriserad Manualer
- Ambient Recording
- Mikrotik
- Aukey
- EKO
- Leatt
- Sena
- Krontaler
- ALM
- Christmas Time
- Bühnen
- Beautifly
- VirtuFit
- Califone
- TESLA Electronics
- Sortimo
Nyaste Inte kategoriserad Manualer
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025