Läs gratis den bruksanvisning för IFM PE3001 (17 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 7 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 4 recensioner. Har du en fråga om IFM PE3001 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/17

Operating instructions
Pressure sensor
PE30xx
704884 / 00 08 / 2010
UK

2
Contents
1 Preliminary note3
1 Symbols used 3
2 Safety instructions 3
3 Functions and features 4
4 Function 5
41 Processing of the measured signals 5
42 Switching function 5
43 Analogue function 6
5 Installation 6
6 Electrical connection6
7 Operating and display elements 7
8 Menu8
81 Menu structure 8
82 Explanation of the menu 9
9 Parameter setting 10
91 Parameter setting general 10
92 Configuring the display (optional) 12
93 Configuration of output 1 12
931 Setting the output function 12
932 Setting the switching limits 12
94 Configuration of output 2 12
95 User settings (optional) 12
951 Setting the delay time for OUT1 12
952 Setting the damping for OUT1 13
96 Service functions 13
961 Reading the min/max values for the system pressure 13
10 Operation 13
101 Read the set parameter values 13
102 Fault indication 13
11 Scale drawing 14
12 Technical data 14
121 Setting ranges 16
13 Factory setting 17

3
UK
1 Preliminary note
1. Symbols used
►Instruction
> Reaction, result
[…] Designation of buttons, switches or indications
→Cross-reference
Important note
Non-compliance can result in malfunctions or interference.
2 Safety instructions
• Read this document before installing the unit. Ensure that the product is suit-
able for your application without any restrictions.
• Non-adherence to the operating instructions or technical data can lead to
personal injury and/or damage to property.
• In all applications check compliance of the product materials ( chapter 12 →
Technical data) with the media to be measured.
• Use in gases at pressures > 25 bar only after contacting the manufacturer ifm
For units with cULus approval and the scope of validity cULus:
The device shall be supplied from an isolating transformer having a secondary
Listed fuse rated as noted in the following table.
Overcurrent protection
Control-circuit wire size Maximum protective device rating
Ampere
AWG (mm2)
26 (0.13) 1
24 (0.20) 2
22 (0.32) 3
20 (0.52) 5
18 (0.82) 7
16 (1.3) 10
The Sensor shall be connected only by using any R/C (CYJV2) cord, having suit-
able ratings.
Produktspecifikationer
Varumärke: | IFM |
Kategori: | Inte kategoriserad |
Modell: | PE3001 |
Behöver du hjälp?
Om du behöver hjälp med IFM PE3001 ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad IFM Manualer
8 April 2025
8 April 2025
8 April 2025
2 April 2025
2 April 2025
1 April 2025
1 April 2025
1 April 2025
31 Mars 2025
12 Mars 2025
Inte kategoriserad Manualer
- Supermicro
- IsoAcoustics
- Blizzard
- Euromaid
- Portkeys
- Gardena
- Autotek
- Nemco
- AJH Synth
- Active Era
- ProUser
- TRIUS
- Greemotion
- Lepu Medical
- Planet
Nyaste Inte kategoriserad Manualer
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025