IFM PIM694 Bruksanvisning

Läs nedan 📖 manual på svenska för IFM PIM694 (27 sidor) i kategorin Inte kategoriserad. Denna guide var användbar för 2 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/27
Operating instructions
Combined sensor for pump diagnosis
and pressure monitoring
PIM693
PIM694
UK
706059 / 00 04 / 2014
2
Contents
1 Preliminary note....................................................................................................3
1. Symbols used 3 ...................................................................................................
2 Safety instructions 3 ................................................................................................
3 Brief instructions 4 ..................................................................................................
4 Functions and features 6 .........................................................................................
5 Function 6 ................................................................................................................
5.1 Processing of the measured signals 6 ..............................................................
5.2 Pump monitoring 7 ............................................................................................
5.3 Pressure monitoring/ analogue function 8 .........................................................
5.4 Pressure monitoring / switching function 9 ........................................................
6 Installation 10 ..........................................................................................................
7 Electrical connection...........................................................................................12
8 Operating and display elements 13 .........................................................................
9 Menu...................................................................................................................14
9. 1 Menu structure 14 ............................................................................................
9. 2 Menu explanation 15 .......................................................................................
10 Parameter setting 16 .............................................................................................
10.1 Parameter setting general 16 ..........................................................................
10.2 Configuring unit for pump diagnosis 18 ...........................................................
10.3 Configuring unit for pressure monitoring 20 ....................................................
10.4 User settings (optional) 21 .............................................................................
10.5 Service functions 22 ........................................................................................
11 Operation 23 ..........................................................................................................
11.1 Read the set parameter values 23 ...................................................................
11.2 Changing the display in the Run mode 23 .......................................................
11.3 Fault indication 24 ............................................................................................
12 Scale drawing 24 ..................................................................................................
13 Technical data ...................................................................................................25
13.1 Setting ranges 26 ............................................................................................
14 Factory setting 27 ..................................................................................................
3
UK
1 Preliminary note
1. Symbols used
Instruction
> Reaction, result
[…] Designation of buttons, switches or indications
Cross-reference
Important note
Non-compliance can result in malfunctions or interference.
2 Safety instructions
• Read the product description before installing the unit. Ensure that the product
is suitable for your application without any restrictions.
• Non-adherence to the operating instructions or technical data can lead to
personal injury and/or damage to property.
• Inallapplicationscheckcomplianceoftheproductmaterials(→chapter13
Technical data) with the media to be measured.
For units with cULus approval and the scope of validity cULus:
The device shall be supplied from an isolating transformer having a secondary
Listed fuse rated as noted in the following table.
Overcurrent protection
Control-circuit wire size Maximum protective device rating
Ampere
AWG (mm2)
26 (0.13) 1
24 (0.20) 2
22 (0.32) 3
20 (0.52) 5
18 (0.82) 7
16 (1.3) 10
The Sensor shall be connected only by using any R/C (CYJV2) cord, having suit-
able ratings.