IFM PL2652 Bruksanvisning
IFM
Inte kategoriserad
PL2652
Läs gratis den bruksanvisning för IFM PL2652 (13 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 6 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 3.5 recensioner. Har du en fråga om IFM PL2652 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/13

Operating instructions
Electronic pressure sensor
PL265x
706070/01 09/2011
UK

2
1 Preliminary note
1.1 Symbols used
►Instruction
> Reaction, result
[…] Designation of buttons, switches or indications
→Cross-reference
Important note
Non-compliance can result in malfunctions or interference.
Contents
1 Preliminary note 2 ...................................................................................................
1.1 Symbols used 2 ................................................................................................
2 Safety instructions 3 ...............................................................................................
3 Functions and features 4 ........................................................................................
3.1 Applications ...................................................................................................4
4 Function ...............................................................................................................5
4.1 Processing of the measured signals 5 ..............................................................
5 Installation............................................................................................................6
6 Electrical connection 7 ............................................................................................
7 Operation .............................................................................................................8
7.1 Cleaning of the filter cover 8 .............................................................................
8 Parameter setting 9 ................................................................................................
8.1 Adjustable parameters 9 ...................................................................................
9 Scale drawing 10 ....................................................................................................
10 Technical data 12 ..................................................................................................
10.1 Setting ranges 13 ...........................................................................................

3
UK
2 Safety instructions
• Read this ducument before installing the unit. Ensure that the product is suit-
able for your application without any restrictions.
• Non-adherence to the operating instructions or technical data can lead to
personal injury and/or damage to property.
• Inallapplicationscheckcomplianceoftheproductmaterials(→10Technical
data) with the media to be measured.
• Use in gases at pressures > 25 bar only after contacting the manufacturer ifm.
For the scope of validity cULus: The device shall be supplied from an isolating
transformer having a secondary Listed fuse rated as noted in the following table.
Overcurrent protection
Control-circuit wire size Maximum protective device rating
Ampere
AWG (mm2)
26 (0.13) 1
24 (0.20) 2
22 (0.32) 3
20 (0.52) 5
18 (0.82) 7
16 (1.3) 10
The Sensor shall be connected only by using any R/C (CYJV2) cord, having suit-
able ratings.
Produktspecifikationer
Varumärke: | IFM |
Kategori: | Inte kategoriserad |
Modell: | PL2652 |
Behöver du hjälp?
Om du behöver hjälp med IFM PL2652 ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad IFM Manualer
8 April 2025
8 April 2025
8 April 2025
2 April 2025
2 April 2025
1 April 2025
1 April 2025
1 April 2025
31 Mars 2025
12 Mars 2025
Inte kategoriserad Manualer
- Econ Connect
- Meec Tools
- Waterdrop
- InSinkErator
- DAB
- Cooper & Quint
- Adler
- Neunaber
- Cablexpert
- STI
- Solo
- Clas Ohlson
- Buffalo
- Q Acoustics
- ATP
Nyaste Inte kategoriserad Manualer
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025