Läs gratis den bruksanvisning för IFM PX9112 (9 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 3 personer och har ett genomsnittsbetyg på 4.6 stjärnor baserat på 2 recensioner. Har du en fråga om IFM PX9112 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/9
Installation Instructions
Electronic pressure sensor
PX3111 
PX322x
PX323x
PX3244
PX3422
PX911x 
PX913x
704571/06 02/2011
2
1  Safety instructions
Please read the product description prior to installing the unit. Please check that
the product is suitable for your application without any restrictions.
If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property may occur.
Please check in all applications that the product materials (see Technical data) are
compatible with the media to be measured.
For gaseous media the application is limited to max. 363 PSI.
High-pressure units (5000 PSI) are supplied with a pressure relief mechanism and
an integrated damping device to comply with the regulations for UL approval and
to avoid any risk of injury in case of bursting when bursting pressure is exceeded.
Any manipulation of the damping device is not permissible.
When the damping device is removed, there is no damping function any
more. ATTENTION: risk of injury!
For units with cULus approval this approval becomes invalid when the
damping device is removed.
Contents
1 Safety instructions ...............................................................................................2
2 Function and features ..........................................................................................4
3 Installation............................................................................................................5
4 Electrical connection ............................................................................................5
5 Scale drawing ......................................................................................................6
6 Technical data ......................................................................................................8
3
For units with cULus approval and the scope of validity cULus:
The device shall be supplied from an isolating transformer having a secondary
Listed fuse rated as noted in the following table.
Overcurrent protection
Control-circuit wire size Maximum protective device rating
Ampere
AWG (mm2)
26 (0.13) 1
24 (0.20) 2
22 (0.32) 3
20 (0.52) 5
18 (0.82) 7
16 (1.3) 10
The Sensor shall be connected only by using any R/C (CYJV2) cord, having suit-
able ratings.

Produktspecifikationer

Varumärke: IFM
Kategori: Inte kategoriserad
Modell: PX9112
Blåtand: Oui
Couleur du produit: Noir
Typ av produkt: Casque
Impedance: - Ohm
Teknik batteri: Lithium-Ion (Li-Ion)
Largeur: 165 mm
Profondeur: 57 mm
Hauteur: 170 mm
Bärbara headset stil: Arceau
Typ hjälm: Monophonique
Technologie de connectivité: Avec fil &sans fil
Connectivité USB: Oui
Bluetooth-modell: 5.0
Profiler Bluetooth: A2DP, AVRCP, HFP, HSP
Bande de fréquence: 2.402 - 2.48 GHz
Räckvidd för trådlös router: 10 m
Öronkoppling: Circum-aural
Hörlursfrekvens: - Hz
Puissance d'entrée maximale: 15 mW
Typ av mikrofon: Boom
Brusreducerande-mikrofon: Oui
Batteridriven: Oui
Type de batterie: Batterie intégré
Capacité de la batterie: 400 mAh
Uppspelning av strömmande ljud: 34 h
Batteriladdningstid: 3 h
Laddar källa: USB
Autonomie en veille: 800 h
Poids: 142 g
Guide de démarrage rapide: Oui
Câbles inclus: USB Type-C

Behöver du hjälp?

Om du behöver hjälp med IFM PX9112 ställ en fråga nedan och andra användare kommer att svara dig