Läs gratis den bruksanvisning för IFM UGR501 (5 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 17 personer och har ett genomsnittsbetyg på 5.0 stjärnor baserat på 9 recensioner. Har du en fråga om IFM UGR501 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/5

Operating instructions
Ultrasonic retro-reflective sensor with IO-Link
UGR500
UGR501
80256300 / 00 07 / 2018
UK

2
1 Preliminary note
1.1 Explanation of symbols
►Instructions
> Reaction, result
→Cross-reference
Important note
Non-compliance may result in malfunction or interference.
Information
Supplementary note.
2 Safety instructions
• Read this document before setting up the product and keep it during the entire
service life.
• The product must be suitable for the corresponding applications and
environmental conditions without any restrictions.
• Only use the product for its intended purpose (→ Functions and features).
• If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property may occur.
• The manufacturer assumes no liability or warranty for any consequences
caused by tampering with the product or incorrect use by the operator.
• Installation, electrical connection, set-up, operation and maintenance of the
product must be carried out by qualified personnel authorised by the machine
operator.
• Protect units and cables against damage.
3 Functions and features
Ultrasonic sensor for the detection of objects.

3
UK
4 Installation
3
4
21
5
►Secure the unit to a bracket
1/2: Status LED (yellow), setting aid
and output indication
3: Echo LED (green), is on when
reector is detected
4: Teach button
5: Reector
The functional specifications refer to a mild steel reflector defined by ifm at
maximum range and with an edge length of 300 mm. The minimum size of
the reflector depends on the size of the object.
With ultrasonic retro-reflective sensors adhere to the minimum distances to
the reflector (→ Technical data sheet).
For units with metal housing (according to UL 508):
►Observe a minimum distance of 12.7 mm between the sensor and non-
insulated live parts.
For further information please refer to www.ifm.com
→ General information about installation and operation.
5 Electrical connection
►Disconnect power.
►Connect the unit:
BK: Black
BN: Brown
BU: Blue
BN1
BK4
BU3
L+
L
OUT
OUT: Switching output / IO-Link
Colours to DIN EN 60947-5-2
Produktspecifikationer
Varumärke: | IFM |
Kategori: | Inte kategoriserad |
Modell: | UGR501 |
Behöver du hjälp?
Om du behöver hjälp med IFM UGR501 ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad IFM Manualer
8 April 2025
8 April 2025
8 April 2025
2 April 2025
2 April 2025
1 April 2025
1 April 2025
1 April 2025
31 Mars 2025
12 Mars 2025
Inte kategoriserad Manualer
- Rode
- Carrier
- Yealink
- Expressive E
- Respironics
- Tronic
- Oras
- Quartet
- ESKA
- Trotec
- CommScope
- Finder
- James
- Panasonic
- Valcom
Nyaste Inte kategoriserad Manualer
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025