Intermatic H10S13Y1DG2 Bruksanvisning


Läs gratis den bruksanvisning för Intermatic H10S13Y1DG2 (2 sidor) i kategorin ej kategoriserat. Guiden har ansetts hjälpsam av 8 personer och har ett genomsnittsbetyg på 4.7 stjärnor baserat på 4.5 recensioner. Har du en fråga om Intermatic H10S13Y1DG2 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/2
NN07325
15802143REF Rev 7/14/20
Page of 1 2
Surge Protective Device (SPD)
Qualified Person
For the purpose of this instruction leaflet, a qualified person:
with their application, use, administration and maintenance.
2 is trained and authorized to de-energize, clear, ground, and tag
circuits and equipment in accordance with established safety
practices.
3 is trained in the proper care and use of personal protective
equipment such as rubber gloves, hard hat, safety glasses or face
shields, arc-flash clothing, etc., in accordance with established
safety practices.
4 is trained to render first aid.
5 has received safety training to recognize and avoid the hazards
involved.
6 has the skills and knowledge pertaining to the construction and
operation of this equipment and its installation.
Installation Instructions
IMPORTANT:
IMPORTANT:
IMPORTANT:
IMPORTANT:IMPORTANT: Read these instructions carefully to assure proper
installation and assembly. Ensure all fasteners and connections are
properly tightened. Installation in a manner inconsistent with these
instructions will void warranty.
To ensure integrity of the finished installation, do NOT install the
SPD if it has been dropped or abused during the installation
process.
The SPD contains no user serviceable parts and cannot be
repaired. Performing the following will compromise the unit’s performance
and will void the warranty. Do NOT:
• Megger or IR (Insulation Resistance) test the system with the SPD installed
• Install in a system that has a voltage greater than the unit’s rated voltage
Ungrounded power systems are inherently unstable and can produce
excessively high line- -ground voltages during certain fault conditions. During to
these fault conditions any electrical equipment, including an SPD, may be
subjected to voltages which exceed their designed ratings. This information is
being provided to the user so that an informed decision can be made before
installing any electrical equipment on an ungrounded power system.
Safety Concerns
This instruction sheet is not comprehensive. It is assumed
the S installer will follow trade and NEC 70E established PD
safety precautions for working in an electrical environment.
Suitable for use on a circuit capable of delivering not more
than 200,000 RMS symmetrical amperes at the nominal
system voltage.
This device features internal protection that will disconnect
the surge protective component at the end of its useful life
but will maintain power to the load - now unprotected. If
the situation is undesirable for the application, follow the
manufacturer’s instructions for replacing the device.
The LED status indicators report the status of the
protection circuitry.
Contains no serviceable parts
Warning - Shock Hazard - Do not open
S General SpecificationsPD
Family
H
H
H
H H
Short-Circuit Current Rating (SCCR)
200 kA
Nominal Discharge Current (8x20 µs) I
n
20 kA
Voltage Frequency
50 / 60 Hz
Conductor Gauge / Type
Stranded 10 AWG / 6 mm
2
Enclosure
NEMA 1, 2, 3, 3R, 3X, 4, 4X
Degree of Protection (Installed State with
liquid tight connections)
IP65
SPD Install Location
Indoor or Outdoor
Operating Temperature
-40
º
C to +65
º
C
-40
º
F to +150
º
F
Recommended Circuit Breaker
30 Amp