IXL Eco Ventflo 10333 Bruksanvisning
Läs gratis den bruksanvisning för IXL Eco Ventflo 10333 (2 sidor) i kategorin Fläkt. Guiden har ansetts hjälpsam av 12 personer och har ett genomsnittsbetyg på 4.5 stjärnor baserat på 6.5 recensioner. Har du en fråga om IXL Eco Ventflo 10333 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
                        Sida 1/2
                    
                    
                    
Installation Instructions and  
User Guide - IXL Eco Ventflo
Read through these instructions fully before commencing installation.  
Locate the IXL Ventflo in accordance with the requirements of the current Australian/New Zealand 
 Wiring Rules AS/NZS 3000 relating to damp situations, or according to applicable Wiring Rules for 
 installations outside of Australia and New Zealand.   
In some installations this may mean that no part of the appliance may be located directly  above 
any part of a bath or shower recess or enclosure.  For unenclosed showers refer to Wiring Rules 
conditions.  This unit is fitted with a cord and plug, however, any interconnecting wiring and switches 
used  or use of another cord and plug must be fitted by a licensed electrician.
Switches and other controls must not be located where they can be touched by a person in  the bath 
or shower.
Warning: 
•  Pull out the power plug before cleaning or maintenance.
•  Do not use this appliance for functions other than those described in this user guide.
•  After removing the appliance from its packaging, ensure that it is complete and undamaged.  
  If in  doubt contact a qualified electrician or IXL Home. Do not leave packaging within the  
  reach of  children or infirm persons.
•  This appliance is not intended for use by persons (including children) with reduced physical,   
  sensory or mental capabilities, or lack of experience and knowledge, unless they have been 
  given  supervision or instruction concerning the use of the appliance by a person responsible  
  for their safety.
•  Young children should be supervised to ensure they do not play with the appliance.
•  Do not operate the appliance in the presence of inflammable vapours (alcohol, insecticides, 
  petrol, etc.)
•  Do not sit or place objects on or in the appliance.
•  The supply cord cannot be replaced. If the cord is damaged the appliance should be scrapped.
•  Do not operate this appliance without the plastic surround in position.
•  This appliance must be mounted with the lowest point at least 2.1 metres from the floor.
•  Ensure that the fan is switched off from supply mains before removing the grille/guard. 
Caution:
•  Do not make modifications of any kind to this appliance. 
•  Do not expose this appliance to the weather (rain, sun, etc.) 
•  Do not immerse the appliance or any parts of it in water or other liquids. Refer to the  
  relevant  instructions to clean the appliance (refer to Cleaning)
•  If the appliance does not function correctly or develops a fault, contact IXL Home immediately.
•  Should the appliance be dropped or suffer a heavy blow, have it checked by an authorised  
  service agent for IXL products.
•  The electrical system to which the appliance is connected must conform to applicable  
  standards.
•  The electrical power supply/socket to which the appliance is to be connected must be able 
  to  provide the maximum electrical power required by the appliance. If it can’t do this,  
  contact a  qualified electrician to make the necessary modifications. 
•  Switch off the appliance at the installation’s main switch: a) if the appliance does not  
  function  correctly; b) before cleaning the outside of the appliance; c) if the appliance is not 
  going to be  used for any length of time.
•  The room must have an adequate source of replacement air for this appliance to function  
  effectively. Moreover, if there is any non-sealed combustion based appliance such as a  
  water/gas  heater, gas stove etc. in the same room, air replacement must be sufficient for  
  all appliances to  work effectively together. 
•  Keep the appliance’s inlet grille/guard free from dust to ensure optimum air flow. 
Safety
Model: 10332 IXL Eco Ventflo Ceiling Exhaust Fan with Draught Shutters 200,
Model: 10333 IXL Eco Ventflo Ceiling Exhaust Fan with Draught Shutters 250, 
(Electric Rating: 230-240 V. 50Hz)
Do not allow insulation material to rest against the sides or top  
of the Ventilation unit when installed
Clearances
Figure 1 measurement A:
Model 10332 (Eco Ventflo 200) 155mm min. 
where there is good ventilation to the sides of  
the unit. 215mm min. where ventilation to the 
sides of the unit is restricted. 
Model 10333 (Eco Ventflo 250) 200mm min. 
where there is good ventilation to the sides of  
the unit. 260mm min. where ventilation to the 
sides of the unit is restricted.
Figure 1 measurement B:
40mm min. clearance on all sides to allow  
clips to fully rotate outwards.
A
B
SHUTTERS
Fig. 1: Minimum clearances for installation
Electrical Requirements
Flat Roof Installations
See the wiring diagram (Fig. 3) for supply requirements and maximum loadings for each model.  Fans 
may be connected to a lighting power circuit if loading permits.  Wiring of the wall switch (not provided) 
and socket outlet in roof cavity must be carried out by a registered electrician.  The wall switch should be 
located in accordance the Wiring Rules AS/NZS 3000.  It must not be installed where it can be reached by a 
person in the bath or shower.
When installing into a flat roof with insufficient 
clearance, or where ceiling cavity ventilation 
is restricted, an external venting duct must be 
installed.  Use Fig. 2 as a guide to minimum 
external outlet requirements. 
IMPORTANT: Do not attach the duct to the body 
of the fan.  Allow for 10-20mm minimum gap 
between the fan and the end of the duct.  
The duct should have a diameter of at least  
235mm (10332) & 290mm (10333).
Fig. 2: Minimum external outlet requirements
Fig. 3: Wiring diagram.
Eco Ventflo unit
Ventilation Requirements
For maximum efficiency and fan performance there are a few key points to keep in mind when 
installing your IXL Eco Ventflo exhaust fan. 
Sufficient air inlet into room
Steam will only be removed if there is sufficient flow of air through the room. Ensure generous 
inlets exist through windows, vents or under the door. Air flow path from inlet to fan should 
ideally pass over the steam sources. (See Fig 4.)
All appliances must be mounted so that the lowest point is at least 2.1m above the floor.   
The IXL Eco Ventflo is designed to fit a ceiling cavity with a minimum height of 155mm (10332) & 
200mm (10333) when installed in a well ventilated roof cavity. Where ventilation is restricted, these 
heights should be increased by a minimum of 60mm.  This will allow for the back draught shutters to 
open fully when the unit is in operation.
Additionally, a minimum of 40mm clearance is required between the sides of the fan and any adjoining 
parts of the roof structure, such as walls, joists or insulation batts.
Adequate ventilation in  
roof cavity 
It is essential that there is adequate 
space within the roof cavity so that 
exhaust air from the fan can dissipate.  
Where space is restricted, use Fig. 1 as 
a guide to minimum requirements for 
adequate ventilation.
The roof cavity itself should be well 
ventilated to outside so that moist 
air can be removed.  Local building 
codes may require flueing to outside 
through roof as per Fig. 2 for flat roof 
installation.
Where ventilation space  
is restricted 
This product is not recommended for 
installation between floors of multi-storey 
dwellings, or where space within the roof 
cavity is severely restricted and a flue as 
per Fig. 2 cannot be fitted. IXL has other 
Ventilation products available that are 
particularly suited to installations between 
floors or where space is restricted.  
For further details and advice on 
ventilation products and tips, contact our 
retail partners or IXL Home customer 
service team.
Fig. 4:  
Ideal placement of Eco Ventflo.   
Sufficient air inlets into room are required.
Shown installed between shower and bath
Shown installed above shower
Produktspecifikationer
| Varumärke: | IXL | 
| Kategori: | Fläkt | 
| Modell: | Eco Ventflo 10333 | 
Behöver du hjälp?
Om du behöver hjälp med IXL Eco Ventflo 10333 ställ en fråga nedan och andra användare kommer att svara dig
Fläkt IXL Manualer
                        
                         12 September 2024
                        
                    
                                                            
                        
                         4 September 2024
                        
                    
                                                            Fläkt Manualer
- Rowenta
 - Zelmer
 - Costway
 - V-Tac
 - Fantech
 - Carrier
 - Esperanza
 - Klarstein
 - Becken
 - Argoclima
 - Solac
 - Hema
 - Orcon
 - Create
 - Broan
 
Nyaste Fläkt Manualer
                        
                         8 April 2025
                        
                    
                                                            
                        
                         8 April 2025
                        
                    
                                                            
                        
                         8 April 2025
                        
                    
                                                            
                        
                         5 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         1 April 2025
                        
                    
                                                            
                        
                         1 April 2025
                        
                    
                                                            
                        
                         1 April 2025