Läs gratis den bruksanvisning för JETI J-ESW4 (4 sidor) i kategorin Radiostyrda leksaker. Guiden har ansetts hjälpsam av 21 personer och har ett genomsnittsbetyg på 4.7 stjärnor baserat på 11 recensioner. Har du en fråga om JETI J-ESW4 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/4

USER MANUAL
E 4 XPANDER SW
By JETI model s.r.o. 17. 4. 2015

Návod k obsluze: Switch Expander
-2-
1. Introduction
The Expander SW4 is an extension for magnetic and switches and is designed for switching RC
multiple devices simultaneously. The JETI model company produces a wide range of devices that can
be switched by magnetic switch or RC switch. The Expander SW4 allows you to combine the switching
duties so that several devices can be controlled using one only element. Furthermore, some outputs are
optically isolated to prevent interference. This makes it is possible to isolate control of devices which
may be sensitive to electric interference.
2. Switch Expander circuitry
Expander SW4 has on output for a magnetic or RC switch and 4 outputs, 3 of them are optically
isolated (OPTO1-OPTO3). The output that is not optically isolated is connected to the magnetic or RC
switch directly, including the power supply (Master input). The optically isolated outputs must be
powered separately. One of the optically isolated outputs is inverted (e.g. for SBEC40) OPT INV. –

Návod k obsluze: Switch Expander
-3-
Fig. 1: Expander SW4 application connection
Circuitry with the RC Switch in case its setting has been changed in the transmitter, it is necessary –
to make sure that the switch is set to normal output (as by default). If the output is set to inverted, the
Expander SW4 would not work correctly. The RC switch is connected to the pander SW4 output Ex
labelled Switch, see Fig. 1.
Circuitry with the magnetic switch – normal output of the magnetic switch is connected to the input
of the Expander SW4 (labelled Switch), see Fig. 1.
If optical connection is needed, the poles of the separated circuits must not be connected an –
anywhere, as well as the +poles.
Magnetic or RC switches, as well as the Expander SW4, are supplied power from the same Master
output. Thus it is necessary to have the power supply connected at least to this connector, see Fig. 1.
If the power supply of the Expander SW4 is interrupted when the magnetic or RC switch is on,
the devices connected to any optically isolated output are switched OFF!! If only a magnetic or
RC switch is disconnected from the Expander SW4, all the devices connected to Expander SW4
outputs remain switched . ON
Please follow all the directives described in individual manuals for the magnetic or RC switch!
Produktspecifikationer
Varumärke: | JETI |
Kategori: | Radiostyrda leksaker |
Modell: | J-ESW4 |
Behöver du hjälp?
Om du behöver hjälp med JETI J-ESW4 ställ en fråga nedan och andra användare kommer att svara dig
Radiostyrda leksaker JETI Manualer
10 September 2024
10 September 2024
10 September 2024
10 September 2024
9 September 2024
9 September 2024
9 September 2024
9 September 2024
9 September 2024
9 September 2024
Radiostyrda leksaker Manualer
- Spin Master
- Tamiya
- Overmax
- Flyzone
- Conrad
- Absima
- Graupner
- Lenoxx
- Reely
- Carrera
- ParkZone
- Hobby Zone
- Blade
- Parrot
- FrSky
Nyaste Radiostyrda leksaker Manualer
14 Juni 2025
31 Mars 2025
30 Mars 2025
30 Mars 2025
30 Mars 2025
30 Mars 2025
30 Mars 2025
29 Mars 2025
29 Mars 2025
29 Mars 2025