Kern FCB 8K0.1 Bruksanvisning

Kern Vågen FCB 8K0.1

Läs gratis den bruksanvisning för Kern FCB 8K0.1 (36 sidor) i kategorin Vågen. Guiden har ansetts hjälpsam av 21 personer och har ett genomsnittsbetyg på 4.6 stjärnor baserat på 11 recensioner. Har du en fråga om Kern FCB 8K0.1 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/36
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
email: info@kern-sohn.com
Phone: +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
Operating Manual
Compact balance
KERN FCB
Version 1.1
01/2009
GB
FCB-BA-e-0911
GB
KERN FCB
Version 1.1 01/2009
Operating Manual
Compact balance
Table of Contents
1 Technical Data ............................................................................................... 4
2 Declaration of conformity ............................................................................. 8
3 Basic Information (General).......................................................................... 9
3.1 Proper use................................................................................................................................. 9
3.2 Improper Use ............................................................................................................................ 9
3.3 Warranty .................................................................................................................................... 9
3.4 Monitoring of Test Resources................................................................................................. 9
4 Basic Safety Precautions ............................................................................ 10
4.1 Pay attention to the instructions in the Operation Manual ................................................ 10
4.2 Personnel training.................................................................................................................. 10
5 Transportation & Storage............................................................................ 10
5.1 Testing upon acceptance ...................................................................................................... 10
5.2 Packaging................................................................................................................................ 10
6 Unpacking, Setup and Commissioning ..................................................... 10
6.1 Installation Site, Location of Use.......................................................................................... 10
6.2 Unpacking/erection ................................................................................................................ 11
Scope of delivery / serial accessories............................................................................................... 11
6.3 Mains connection ................................................................................................................... 11
6.4 Operation using a (rechargeable) battery (optional) .......................................................... 12
6.5 Connection of peripheral devices......................................................................................... 12
6.6 Initial Commissioning ............................................................................................................ 13
6.7 Adjustment.............................................................................................................................. 13
6.8 Adjustment.............................................................................................................................. 13
7 Operation elements ..................................................................................... 14
7.1 Overview of display................................................................................................................ 14
7.2 Keyboard overview................................................................................................................. 14
FCB-BA-e-0911
2
FCB-BA-e-0911
3
8 Basic Operation ........................................................................................... 15
Start-up................................................................................................................................................. 15
Switching Off ....................................................................................................................................... 15
Weighing .............................................................................................................................................. 15
Taring.................................................................................................................................................... 15
PRE-TARE-Function............................................................................................................................ 16
Plus/minus weighings......................................................................................................................... 17
Parts counting ..................................................................................................................................... 17
Net-total weighings ............................................................................................................................. 18
Percent determination ........................................................................................................................ 19
9 Menu ............................................................................................................. 20
9.1 Navigation in the menu..........................................................................................................20
9.2 Menu overview........................................................................................................................ 23
9.3 Description of individual menu items .................................................................................. 25
Weighing Units .................................................................................................................................... 25
Dosing and Zero-tracking................................................................................................................... 26
Selection adjustment weight.............................................................................................................. 26
Display background illumination....................................................................................................... 27
Animal weighing function................................................................................................................... 28
Reset to factory setting ..................................................................................................................... 29
9.4 Interface parameters .............................................................................................................. 30
Data transfer mode.............................................................................................................................. 30
printout ................................................................................................................................................. 31
Baud rate .............................................................................................................................................. 32
10 Data output RS 232 C .................................................................................. 32
10.1 Technical Data ........................................................................................................................ 32
10.2 Pin allocation of balance output bushing:........................................................................... 32
10.3 Explanation of the data transfer ........................................................................................... 33
10.4 Output on bar code printer.................................................................................................... 35
11 Service, maintenance, disposal.................................................................. 35
11.1 CLEANING............................................................................................................................... 35
11.2 Service, maintenance............................................................................................................. 35
11.3 Disposal................................................................................................................................... 35
12 Instant help................................................................................................... 36
FCB-BA-e-0911
4
1 Technical Data
KERN FCB 3K0.1 FCB 6K0.5 FCB 6K1
Readability (d) 0.1 g 0.5 g 1 g
Weighing range (max) 3 kg 6 kg 6 kg
Taring range (subtractive) 3 kg 6 kg 6 kg
Reproducibility 0.1 g 0.5 g 1 g
Linearity 0.3 g 1.5 g 3 g
Minimum unit weight at
piece counting
0.2 g 1 g 2 g
Warm-up time 2 hours 30 minutes 30 minutes
Reference quantities at
piece counting
5, 10, 20,25, 50
Weighing Units
Details „Weighing units“ see chpt. 9.3
Recommended adjustment weight,
not added (class).
Details for „Selection of the
Adjustment weight“ in chpt. 9.3
3 kg (M1) 6 kg (F2) 6 kg (M2)
Stabilization time (typical) 3 sec.
Operating temperature + 5° C ... + 35° C
Humidity of air max. 80 % (not condensing)
Housing (B x D x H) mm 270 x 345 x 106
Weighing plate mm 252 x 228
Weight kg (net) 3
FCB-BA-e-0911
5
KERN FCB 8K0.1 FCB 12K1 FCB 15K5
Readability (d) 0.1 g 1 g 5 g
Weighing range (max) 8 kg 12 kg 15 kg
Taring range (subtractive) 8 kg 12 kg 15 kg
Reproducibility 0.1 g 1 g 5 g
Linearity 0.3 g 3 g 10 g
Minimum unit weight at
piece counting
0.2 g 2 g 10 g
Warm-up time 2 hours 30 minutes 10 minutes
Reference quantities at
piece counting
5, 10, 20, 25, 50
Weighing Units
Details „Weighing units“ see chpt. 9.3
Recommended adjustment weight,
not added (class).
Details for „Selection of the
Adjustment weight“ in chpt. 9.3
8 kg (F2) 12 kg (M1) 15 kg (M2)
Stabilization time (typical) 3 sec.
Operating temperature + 5° C ... + 35° C
Humidity of air max. 80 % (not condensing)
Housing (B x D x H) mm 270 x 345 x 106
Weighing plate mm 252 x 228
Weight kg (net) 3
FCB-BA-e-0911
6
KERN FCB 16K0.2 FCB 24K1 FCB 24K2
Readability (d) 0.2 g 1 g 2 g
Weighing range (max) 16 kg 24 kg 24 kg
Taring range (subtractive) 16 kg 24 kg 24 kg
Reproducibility 0.2 g 1 g 2 g
Linearity 0.6 g 3 g 6 g
Minimum unit weight at
piece counting
0.4 g 2 g 4 g
Warm-up time 2 hours 30 minutes 30 minutes
Reference quantities at
piece counting
5, 10, 20, 25, 50
Weighing Units
Details „Weighing units“ see chpt. 9.3
Recommended adjustment weight,
not added (class).
Details for „Selection of the
Adjustment weight“ in chpt. 9.3
16 kg (M1) 20 kg (M1) 20 kg (M1)
Stabilization time (typical) 3 sec.
Operating temperature + 5° C ... + 35° C
Humidity of air max. 80 % (not condensing)
Housing (B x D x H) mm 270 x 345 x 106
Weighing plate mm 252 x 228
Weight kg (net) 3
FCB-BA-e-0911
9
3 Basic Information (General)
3.1 Proper use
The balance you purchased is intended to determine the weighing value of material
to be weighed. It is intended to be used as a “non-automatic“ balance, i.e. the
material to be weighed is manually and carefully placed in the centre of the weighing
plate. As soon as a stable weighing value is reached the weighing value can be read.
3.2 Improper Use
Do not use balance for dynamic weighing. In the event that small quantities are
removed or added to the material to be weighed, incorrect weighing results can be
displayed due to the “stability compensation“ in the balance. (Example: Slowly
draining fluids from a container on the balance). Do not leave permanent load on the
weighing plate. This may damage the measuring system. Impacts and overloading
exceeding the stated maximum load (max) of the balance, minus a possibly existing
tare load, must be strictly avoided. Balance may be damage by this.
Never operate balance in explosive environment. The serial version is not explosion
protected.
The structure of the balance may not be modified. This may lead to incorrect
weighing results, safety-related faults and destruction of the balance.
The balance may only be used according to the described conditions. Other areas of
use must be released by KERN in writing.
3.3 Warranty
Warranty claims shall be voided in case
Our conditions in the operation manual are ignored
The appliance is used outside the described uses
The appliance is modified or opened
Mechanical damage and damage caused by media, liquids
Natural wear and tear
The appliance is improperly set up or incorrectly electrically connected
The measuring system is overloaded
3.4 Monitoring of Test Resources
In the framework of quality assurance the measuring-related properties of the
balance and, if applicable, the testing weight, must be checked regularly. The
responsible user must define a suitable interval as well as type and scope of this test.
Information is available on KERN’s home page (www.kern-sohn.com) with regard to
the monitoring of balance test substances and the test weights required for this. In
KERN’s accredited DKD calibration laboratory test weights and balances may be
calibrated (return to the national standard) fast and at moderate cost.


Produktspecifikationer

Varumärke: Kern
Kategori: Vågen
Modell: FCB 8K0.1

Behöver du hjälp?

Om du behöver hjälp med Kern FCB 8K0.1 ställ en fråga nedan och andra användare kommer att svara dig