Kyoritsu 8329 Bruksanvisning
Läs gratis den bruksanvisning för Kyoritsu 8329 (1 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 25 personer och har ett genomsnittsbetyg på 4.2 stjärnor baserat på 13 recensioner. Har du en fråga om Kyoritsu 8329 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
                        Sida 1/1
                    
                    
                    
1. Features
  This product is an optional accessory and designed for our KEW5050 Ior 
leakage current logger. It can supply electrical power to KEW5050 when 
combined  and  used  together  with  MODEL8262  AC  adapter  and 
MODEL7278 earth cable. In this case, KEW5050 can measure voltages 
up to 240 V AC (50/ 60 Hz).
2. Safety warnings
  This product has been designed, manufactured and tested according to 
IEC 61010: Safety requirements for electronic measuring apparatus, and 
delivered  in  the  best  condition  after  passing  quality  control  tests.  This 
instruction manual contains warnings and safety procedures which have 
to be observed by the user to ensure safe operation of the product and to 
maintain  it  in  safe  condition.  Therefore,  read  through  these  operating 
instructions before starting to use the product.
#
 WARNING
  Read through and understand the instructions contained in this manual 
before starting to use the product.
  Keep  the  manual  at  hand  to  enable  quick  reference  whenever 
necessary.
 The product is to be used only in its intended applications.
  Understand  and  follow  all  the  safety  instructions  contained  in  the 
manual.
It is essential that the above instructions are adhered to. Failure to follow 
the  above  instructions  may  cause  injury  or  product  damage,  and/or 
damage to the equipment  under  test.  Kyoritsu  assumes no responsibility 
for damage and injury caused by misuse or not following the instructions 
in the manual.
The  symbol    indicated  on  the  product,  means  that  the user  must refer  to #
the related parts in the manual for safe operation of the product. It is essential 
to read the instructions wherever the symbol appears in the manual.
#
 DANGER:   is  reserved  for  conditions  and  actions  that  are  likely  to 
cause serious or fatal injury.
#
 WARNING:  is  reserved  for  conditions  and  actions  that  can  cause 
serious or fatal injury.
#
 CAUTION:   is  reserved  for  conditions  and  actions  that  can  cause 
injury or instrument damage.
#
 DANGER
  Do  not  attempt  to  use  in  the  presence  of  flammable  or  explosive 
gasses, or in steam environment. 
 Never attempt to use the product if its surface or your hand is wet.
The product is to be used only in its intended applications or conditions. 
Otherwise, safety functions equipped with the product doesn't work, and 
damage to the product or serious personal injury may occur. 
  When  the  product  is  used  with  KEW5050,  the  max  rated  voltage  to 
ground will be 150 V AC in CAT III or 240 V in CAT II. The rating differs 
from the one of  reference  voltage  input terminal  of KEW5050.  Do  not 
exceed the measurement category range or not test a circuit in which 
higher voltage to ground exists; otherwise, this product, AC adapter or 
KEW5050 may be damaged or electrical accident may occur.
 Rated power frequency of the product is 50/ 60 Hz.
 Use MODEL7273 voltage test leads supplied with KEW5050.
 Use MODEL8262 AC adapter supplied with KEW5050.
 Ensure that the power plug is firmly connected to the AC adapter.
  Always  connect  the  product  to  KEW5050  first,  and  then  to  the 
measurement line.
  Do not disconnect voltage test leads from the input terminals (N/ L) of 
the product during a measurement. 
 Do not disconnect the product from KEW5050 during a measurement.
  Disconnect  all  the  cables  connected  to  the  product  before  replacing 
fuses; put a new fuse of the same rating. 
#
 WARNING
 Turn off the power switch when connecting to KEW5050.
 Keep the fuse holder cover screwed and closed during a measurement.
  Never  attempt  to  make  measurement  if  any  abnormal  conditions  are 
noted, such as cracks or exposed metal parts.
  Do not install substitute parts or make any modification to the product. 
Return the product to your local Kyoritsu distributor for repair.
#
 CAUTION
  Examine  the  conductor  under  test  before  starting  a  measurement;  it 
might be hot.
 Never give strong vibrations or drop shocks.
  The product  is not dust/  water-proof.  Do not use  the product  at dusty 
places or to be spattered.
 Care should be taken so as not to damage the cable jacket. 
 Do not pull or bend the root of the cable to prevent a break in the cable. 
  Use  a  damp  cloth  with  neutral  detergent  or  water  for  cleaning  the 
product. Do not use abrasives or solvents.
Meaning of symbols on the product:
#
User must refer to the explanations in the instruction manual.
Double or reinforced insulation
AC
Crossed-out  wheel  bin  symbol  (according  to  WEEE  Directive: 
2002/96/EC)  indicating  that  this  electrical  product  may  not  be 
treated  as  household  waste,  but  that  it  must  be  collected  and 
treated separately.
MODEL 8329
Instruction manual
Power supply adapter
Measurement Category
To ensure safe operation of measuring instruments, IEC 61010 establishes 
safety  standards  for  various  electrical  environments,  categorized  as  O  to 
CAT  IV,  and  called  measurement  categories.  Higher-numbered  categories 
correspond to electrical environments with greater momentary energy, so a 
measuring  instrument  designed  for  CAT  III  environments  can  endure 
greater momentary energy than one designed for CAT II.
O (None, other)
 :  Circuits  which  are  not  directly  connected  to  the  mains 
power supply. 
CAT II  :  Electrical  circuits  of  equipment  connected  to  an  AC 
electrical outlet by a power cord.
CAT III  :  Primary  electrical  circuits  of  the  equipment  connected 
directly  to  the  distribution  panel,  and  feeders  from  the 
distribution panel to outlets.
CAT IV  :  The  circuit  from  the  service  drop  to the  service  entrance, 
and to the power meter and primary overcurrent protection 
device (distribution panel).
3. Specifications
Input voltage 100 to 240 V AC (50 Hz/ 60Hz)
Location for use In-door use, altitude 2000m or less
Operating Temp. & 
Hum. range
- 10ºC to 50 ºC, relative humidity 85% or less (no condensation)
Storage Temp. & 
Hum. range
- 20ºC to 60ºC, relative humidity 85% or less (no condensation)
Dimension 90.6 (L) x 43 (W) x 47.5 (D) mm * excluding the plug & cable
Weight Approx. 115g
Cable length Approx. 180mm
Fuse rating 500 mA / 600 V AC, fast acting type, Ø6.3 × 32mm
Accessories One fuse (installed), Instruction manual
Applicable 
   standard
IEC61010-1 CAT III 150 V CAT II 240 V Pollution degree 2
IEC60529 IP 40
4. How to use
1
  Ensure that KEW5050 and MODEL8329 are both powered off.
2
   Connect  MODEL7273  voltage  test leads  to  the  power  input  terminals 
(N/  L)  of  MODEL8329  respectively,  and  then  connect  the  plugs  of 
MODEL 8329 to the reference voltage input terminals of KEW5050.
3
   Firmly  connect  the  power  plug  of  MODEL8329  to  MODEL8262  AC 
adapter.
4
   Connect the output terminal of MODEL8262 AC adapter to the female 
connector of MODEL7278 earth cable.
5
   Firmly connect the connection terminal of MODEL7278 earth  cable  to 
the AC adapter connector on KEW5050.
6
   Connect  the  clip  of  MODEL7278  earth  cable  to  a  well-known  earth 
terminal.
MODEL7278 earth cable
#
 DANGER
  Always  check  so  as  not  to  connecting  the  clip  other  than  earth 
terminal. 
  Never connect to a live wire.
Note:
  Always earth the product with the supplied earth cable when making 
measurements  using AC  adapter;  otherwise,  stable  readings cannot 
be obtained.
7
   Connect the alligator clip of MODEL7273 voltage test lead to the circuit 
under test. 
8
   Power on KEW5050.
9
   Power on MODEL8329.
         Confirm that 
 (AC adapter) icon appears on the LCD of KEW5050. 
If 
 (Battery) icon is displayed, the connections may incorrect or the 
fuse inside MODEL8329 may have blown. 
Reversed procedure is applied to remove the product.
5. Product layout
6. Fuse replacement
1
  Ensure that the power switch is set to OFF.
2
   Disconnect all cables from the product.
3
   Loosen the screw on the top side, and remove the fuse holder cover.
4
   Take out the fuse*.
*500 mA / 600 V AC, fast acting type, Ø6.3 × 32mm
5
   Set a new fuse to the fuse holder.
6
   Attach and screw the fuse holder cover.
DISTRIBUTOR
Kyoritsu reserves the rights  to  change  specifications  or  designs  described  in this 
manual without notice and without obligations.
11-17  92-2312A
Incoming wire
O:
Device which is  
    not directly 
    connected to the 
    mains power supply
Socket
Interior wiring
Power plug 
Mains input terminal (N/ L)
Power switch
Fuse holder cover
Plug (N
(T)
 / L
(R)
) 
Screw
Cable 
MODEL 
7273
MODEL 
MODEL8262
7278
MODEL 
KEW5050
8329
240V 
or less
Produktspecifikationer
| Varumärke: | Kyoritsu | 
| Kategori: | Inte kategoriserad | 
| Modell: | 8329 | 
Behöver du hjälp?
Om du behöver hjälp med Kyoritsu 8329 ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad Kyoritsu Manualer
                        
                         18 September 2024
                        
                    
                                                            
                        
                         18 September 2024
                        
                    
                                                            
                        
                         18 September 2024
                        
                    
                                                            
                        
                         18 September 2024
                        
                    
                                                            
                        
                         18 September 2024
                        
                    
                                                            
                        
                         18 September 2024
                        
                    
                                                            
                        
                         18 September 2024
                        
                    
                                                            
                        
                         17 September 2024
                        
                    
                                                            
                        
                         17 September 2024
                        
                    
                                                            Inte kategoriserad Manualer
- Promise Technology
- BlueDri
- PATLITE
- Procare
- Hagor
- Boso
- POGS
- Bestar
- Pfaff
- IMG Stage Line
- KS Tools
- Gemini
- Newport Brass
- JDC
- Glide Gear
Nyaste Inte kategoriserad Manualer
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025