LG ARND153DCR4 Bruksanvisning

LG Luftkonditionering ARND153DCR4

Läs gratis den bruksanvisning för LG ARND153DCR4 (50 sidor) i kategorin Luftkonditionering. Guiden har ansetts hjälpsam av 2 personer och har ett genomsnittsbetyg på 4.6 stjärnor baserat på 1.5 recensioner. Har du en fråga om LG ARND153DCR4 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/50
AIR
CONDITIONER
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring standards
by authorized personnel only.
Please retain this installation manual for future reference after reading it thoroughly.
www.lghvac.com
www.lg.com
Copyright © 2021 LG Electronics Inc. All Rights Reserved.
ENGLISH
SE UENCE MANUALQ
CONTROLLER
MFL71810502
Re .00v
LG SPLIT COMPACT DEDICATED OUTDOOR AIR SYSTEM(DOAS)
2
Introduction
NOTE:
Please read and save this instructions for future reference.
Read Carefully before attempting to assemble, install, operate
or maintain the product described. Protect yourself and others
by observing all safety information. Failure to comply with
these instructions will result in voiding of the product warranty
and may result in personal injury and/or property damage
WARNING
Electrical shock hazard. Can cause personal injury or
equipment damage. Service must be performed only by
personnel that are knowledgeable in the operation of the
equipment being controlled.
This Manual for Split Rooftop and Compact DOAS, It
should be read considering that there are structural
dierences.
Note:
RTD: Rooftop DOAS (ARND***DB Series) **
CTD: Compact DOAS (ARND***DC** Series)
Program Features
The microprocessor controller oers control through
easy monitoring and adjustment of unit parameters by
way of a lighted graphical display and an integral push-
button keypad.
Pre-Programmed Operating Sequences
The controller has been pre-programmed to oer
multiple control sequences to provide tempered air.
Factory default settings allow for easy setup and
commissioning. The sequence parameters are fully
adjustable. Refer to the Sequence of Operation for
details
BMS Communication
The user can remotely adjust set points, view unit status
points and alarms. The microprocessor controller is
capable of communicating over several protocols:
  BACnet® IP Modbus RTU
Reference Points List for a complete list of BMS points
Alarm Management
The microprocessor controller will monitor the unit’s
status for alarm conditions. Upon detecting an alarm, the
controller will record the alarm description, time, date.
Occupancy Modes
The microprocessor controller oers two modes of
determining occupancy: a digital input the BMS. If in the
unoccupied mode, the unit will either be shut down,
continue normal operation utilizing adjustable
unoccupied set points, recirculate with unoccupied set
points or will cycle on to maintain adjustable unoccupied
room temperature and humidity set points (room
temperature and humidity sensor is optional ).
Display Panel
The Web UI and Display are two ways to gain access to
the unit controller allowing monitoring of the unit and
parameter adjustment without being at the unit.
The Web UI can be accessed via a building network and
is included with every unit controller. The Display is an
LCD to be panel mounted in a controller section in the
unit.
3
TABLE OF CONTENTS
TAB C N NLE OF O TE TS ............................... ............................... ............................................................... .......................... 3. . .
NAVI I NGAT O ............................................................... ............................... ............................................................... ............ . .
PA ARAME ET R DJU NSTME T ............................... ............................... ............................................................... ................ 5. . .
MAIN NME U ............................................................... ............................... ............................................................... .............. . .
SE E EQU NCE OF OP RATION............................... ............................... ............................................................... ................ 7. . .
C N R WO T OLL RE OV VER IE ............................... ............................... ............................................................... ................. . . .10
UN T UI STAT S............................... ............................................................... ............................... ....................................... 4. . . .1
T TEMPERATUR C NE O ROL ............................... ............................... ............................................................... ................ . . .16
D HU DE MI IFI ICAT ON ............................... ............................................................... ............................... ........................... 7. . . .1
DAMPER C N RO T OL............................... ............................................................... ............................... ............................ 8. . . .1
F TAN C NO ROL ............................... ............................................................... ............................... .................................... 9. . . .1
OCCU CPAN Y ............................... ............................................................... ............................... ........................................ . . .2
EC NO OMIZER ............................... ............................................................... ............................... ...................................... 0. . . .2
CO2IN R CTE LO K............................... ............................................................... ............................... ................................... . . .2
A ADV NCED ............................................................... ............................... ............................................................... ........... . . .2
C C N ROIL O T OL ............................... ............................................................... ............................... .................................... . . .2
SE S SEN OR TTINGS............................... ............................................................... ............................... ............................ 2. . . .2
N R NETWO K SETTI GS ............................... ............................................................... ............................... ........................ 3. . . .2
A ADV CNED C N RO T OL............................... ............................... ............................................................... ....................... 4. . . .2
A AL RM ............................................................... ............................... ............................................................... ................... . . .2
SETTINGS ............................................................... ............................... ............................................................... .............. . . .2
SOFTWAR UE PDATE ............................... ............................................................... ............................... .......................... 7. . . .2
WE E EB US R INT RFACE............................... ............................... ............................................................... ...................... . . .28
B CA N DBU NET/MO S POI TS LIST............................................................... ............................... ....................................... . .43
O O O EPE SN URCE S F ETWAR N COTI OSS I EL O T OLLE . . . .NOT C -30 5_ _ RE 9 DO SA CA C N R R 1_ 0 0 0_ 092120 HTML
............................... ............ .45

Produktspecifikationer

Varumärke: LG
Kategori: Luftkonditionering
Modell: ARND153DCR4
Enhetsplacering: Ingebouwd
Typ av operation: Scrollbar, Touch
Färg på produkten: Zwart
Antal effektnivåer: 9
Inbyggd display: Ja
Timer: Ja
Vikt: 10500 g
Bredd: 600 mm
Djup: 545 mm
Höjd: 53 mm
Barnlås: Ja
Håll varm funktion: Ja
Typ av material (överst): Glaskeramiek
Brännare/kokzonseffekt 2: 3000 W
Brännare/kokzonseffekt 3: 3700 W
Brännare/kokzonseffekt 1: 3700 W
Antal brännare/kokzoner: 4 zone(s)
Typ av häll: Inductiekookplaat zones
Brännare/kokzon typ 1: Groot
Brännare/kokzon typ 2: Regulier
Typ av brännare/kokzon 3: Groot
Antal gasbrännare: 0 zone(s)
Antal elektroniska kokzoner: 4 zone(s)
Normal brännare/kokzon: 3700 W
Kontrollposition: Boven voorzijde
Ansluten last (elektrisk): 7400 W
Installationsfackets bredd: 585 mm
Installationsfack höjd: 50 mm
Ansluten last (gas): 0 W
Automatisk avstängning: Ja
Skriv timer: Digitaal
Forma vanlig brännare/kokzon: Rechthoekig
Installationsutrymmets djup (min): 490 mm
Varningssignal: Ja
Restvärmeindikator: Ja
Antal kokzoner som ska användas samtidigt: 4
Mått (B x D) normal brännare/kokzon: 180 x 200 mm
Ramtyp: Full trim
Pansigenkänning: Ja
Rengöringslås: Ja
Ramfärg: Chroom
Ramform: Direct
Typ av brännare/kokzon 4: Regulier
Brännare/kokzonseffekt 4: 3000 W
Strömkälla brännare/kokzon 1: Electrisch
Strömkälla brännare/kokzon 2: Electrisch
Strömkälla brännare/kokzon 3: Electrisch
Strömkälla för brännare/kokzon 4: Electrisch
Installationsutrymmets djup (max): 530 mm
Placera brännare/kokzon 1: Links achter
Diameter brännare/kokzon 1: 210 mm
Placera brännare/kokzon 2: Links voor
Brännare/kokzons diameter 2: 180 mm
Placera brännare/kokzon 3: Rechts achter
Brännare/kokzons diameter 3: 210 mm
Placera brännare/kokzon 4: Rechts voor
Brännare/kokzons diameter 4: 180 mm
Kokzon 1 form: Rond
Kokzon 2 form: Rond
Kokzon 3 form: Rond
Kokzon 4 form: Rond
AC-ingångsspänning: 230-400 V
AC-ingångsfrekvens: 50 - 60 Hz

Behöver du hjälp?

Om du behöver hjälp med LG ARND153DCR4 ställ en fråga nedan och andra användare kommer att svara dig