Läs gratis den bruksanvisning för Lowell SEQ-8 (4 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 23 personer och har ett genomsnittsbetyg på 3.6 stjärnor baserat på 12 recensioner. Har du en fråga om Lowell SEQ-8 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/4

Lowell strives to provide accurate information while reserving the right to change specications and/or improve manufacturing methods without prior notication.
©2021 Lowell Manufacturing Co., 100 Integram Dr., Pacic MO 63069 / tel. 800.325.9660 / www.lowellmfg.com
Spec 1603
Model SEQ-8 Rev. 08-12-21 | pg. 1/4
INTERNAL USE ONLY: PN 24369
Compact low voltage eight step sequencer model SEQ-8 is
designed to work with single or multiple external switches and
low voltage remote power controls (RPCs) to provide time-
delayed activation and deactivation of AC powered equipment
on site or at remote locations.
Note: This sequencer is for use with compatible components that feature classic
connections. It is not for use with devices that feature pass-through connections.
FEATURES:
• Power Requirement: 100-240VAC 12W
• Activation Trigger: Sequencing is initiated by a remote
external SPST switch or switches (order separately). Slide the
bar to select single or multiple switch mode.
– For Single Switch Applications: Use an SPST switch with
MAINTAINED contact closure.
– For Multiple Switch Applications: Use SPST switches with
MOMENTARY contact closure.
• Eight (8) Step Delay:
– Eight time-delayed closure circuits activate in sequential
order (1, 2, 3, 4, 5, 6, 7, 8) and deactivate in reverse order.
– The delay between steps can be adjusted via an externally
accessible trimpot (0.5-10 seconds).
– LEDs provide visual status of the sequence.
– Includes auxiliary 24VDC output (300mA max.) for use with
remote indicators.
• Compact Chassis: 10" x 3.28" x 1.69" steel chassis with
black powder epoxy finish and mounting holes.
– Unit can be installed in a remote location or rack panel (2U).
– Operational diagram printed on top of chassis aids system
set-up.
• Country of Origin: Made in U.S.A. with global components
• Power Supply: UL Listed power supply (100-240VAC input,
24VDC 500mA output) with 6 ft. cord and NEMA 1-15P plug.
Includes three adaptors for international use (Schuko CEE
7/16, BS1362, AS3112).
• Installation: The sequencer is typically installed in a
convenient location, while remote power controls are placed
near equipment to be controlled—in another rack, room or
building.
– Maximum distance between sequencer and remote power
controls: 22 gauge wire = 6,600 ft.; 18 gauge wire =
17,160 ft.
– Maximum distance between sequencer and switch:
22 gauge wire = 100 ft.; 18 gauge wire = 200 ft.
– System Capacity: Accepts up to 10 RPCs per step.
• Connections: Order compatible remote power controls and
switches separately. (See last page.)
• A&E Specications: The power sequencer shall be Lowell
model SEQ-8, which shall feature barrier strip terminals for
connection to a single external SPST switch with maintained
contact closure or multiple external SPST switches with
momentary closure. The sequencer shall connect to remote
power controls (RPCs) to activate equipment in up to eight
steps with an adjustable time delay between each step. It shall
activate the RPCs in sequential order and deactivate them in
reverse order. The sequencer shall feature a steel chassis
with mounting holes, black powder epoxy finish, and overall
dimensions of 10" x 3.28" x 1.69". shall be made in the It
USA with global components, and include a UL Listed power
supply with NEMA 1-15P plug and three adaptors (Schuko
CEE 7/16, BS1362, AS3112). External switch(es) and remote
power controls are required for sequencer use and shall be
ordered separately.
Low Voltage Sequencer (8 step): SEQ-8
Made in USA
INPUT for activation trigger (select single or multiple switches)
Chart for connections
Screwdriver-adjustable delay setting
Includes power supply
with NEMA 1-15P plug
and three adaptors
OUTPUT to connections
(up to 10 RPCs per circuit)
LEDs show sequencing status
Produktspecifikationer
| Varumärke: | Lowell |
| Kategori: | Inte kategoriserad |
| Modell: | SEQ-8 |
Behöver du hjälp?
Om du behöver hjälp med Lowell SEQ-8 ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad Lowell Manualer
3 April 2025
11 December 2024
11 December 2024
7 December 2024
7 December 2024
7 December 2024
7 December 2024
7 December 2024
7 December 2024
7 December 2024
Inte kategoriserad Manualer
- Bomann
- Salus
- Intertechno
- Xtorm
- Rega
- Equip
- G-Technology
- OzCharge
- Point 65
- Python
- 4moms
- Vaillant
- Tovsto
- X-Lite
- Gitzo
Nyaste Inte kategoriserad Manualer
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025