Master Lock 1500 Bruksanvisning
Läs gratis den bruksanvisning för Master Lock 1500 (2 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 16 personer och har ett genomsnittsbetyg på 4.4 stjärnor baserat på 8.5 recensioner. Har du en fråga om Master Lock 1500 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
                        Sida 1/2
                    
                    
                    
HOW TO CHANGE THE PRIMARY CODE Fig. A
Primary Code
UP
DOWN
Guest Code
RIGHT
Guest 
Code
LEFT
Guest 
Code
Fig. B
eONE™ User Manual 
Instructional Video at www.masterlock.com 
INDOOR USE ONLY 
(between 0°C to 50°C) 
Do not allow lock to get wet. 
KEEP THIS USER MANUAL FOR REFERENCE
CODE TYPES
Primary Code (Factory-set code, shown above):
• Stored at the UP arrow position.  • Can be changed, but not deleted. 
• Total access and programming control.   • Must be 4-12 positions in length.  
• For greater security, use a longer code with multiple directions.
Backup Master Code:
• Visit masterlockvault.com and enter Vault
® Product Code shown above right. 
• Factory-set code, unique to this lock, cannot be changed or deleted.
•  When entering your Backup Master Code, press and hold the Center Button. While continuing 
to press the Center Button, once the arrows fade, press the first position in the Code, and then 
release both buttons. Continue entering the rest of the code.
• Total access and programming control. 
Guest Codes: 
• Up to 3 Guest Codes can be set by Primary Code user or Backup Master Code user. 
• No Guest Codes are factory-set. 
• Can be stored at the RIGHT, DOWN or LEFT arrow positions. 
• No programming control. 
• Must be 4-12 positions in length. 
• For greater security, use a longer code with multiple directions.
NOTE: To safeguard programming access for the Primary Code user, a Guest Code cannot match 
or start with the same sequence of the current Primary Code (i.e. if Primary Code is UP/DOWN/
LEFT/RIGHT, a Guest Code cannot exactly match or start with UP/DOWN/LEFT/RIGHT).
LOCK STATUS
The center button and arrows light to indicate lock status during operation and programming. See 
the LED Display Chart below or www.masterlock.com for  
additional information.
HOW TO OPEN THE LOCK
1.   Enter a code by pressing the corresponding arrows. Do not pull on the shackle  
during code entry.
  •   All arrows light blue when any arrow is pressed. The center button lights blue during code 
entry. If the buttons do not light, or if the center button flashes yellow during code entry, the 
battery needs to be replaced.
  •   To clear the code entry at any time, press the center button. Re-enter the code  
from the beginning.
  •   After three consecutive incorrect code entry attempts, the lock times out  
and center button fades in and out red for one minute.
  •   When the proper code is entered, the center button lights green and the arrows  
light clockwise twice.
2.   After the center button lights green, open the lock within 5 seconds or lock will relock.
General Operation - LED Display Chart 
LED Display Status Condition
Arrows and center button on for 1 second. Wake Up When in locked sleep mode and center button is pressed.
(First arrow button pressed counts towards code entry)
Center button lights blue and arrows flash with each press. Code Entry When in locked sleep mode and any arrow button is pressed or during code 
entry to unlock.
Center button green for 1 second. Arrows rotate clockwise twice. Correct Code After valid code is accepted, shackle can be pulled open.
Center button blue. Arrows flash twice. Clear Entry After center button is pressed to clear a code entry.
Center button flashes red 3 times. Code Failed - Max. Length After 12 arrow button presses are made.
Center button green for 1 second. Arrows rotate counter-clockwise twice. After shackle is closed.Locked
Center button fades in and out red in 1 second, then off for 2 seconds.  
Repeats for 1 minute.
Lockout - 3 Incorrect Code Entries After 3rd incorrect code entry. Pressing center button during code entry to clear 
the lock counts as incorrect entry.
Center button red for 1 second, then sleep mode. Time Out 5 seconds after last button press in locked mode.
5 second time out, no lights on. Time Out - Lock Not Opened 5 seconds after unlocking without raising the shackle. Lock relocks.
Center button flashes yellow for 4 seconds. Low Battery After first button press from locked sleep mode if battery voltage low.
Program Mode - LED Display Chart
LED Display Status Condition
Center button white. Each arrow with a stored code lights until button is 
pressed.
Stored Code Positions After pressing center button 2 seconds to enter Program Mode.
Center button white. Selected arrow position flashes twice, then all ar-
rows off.
Arrow Position Selection After pressing an arrow followed by the center button.
Center button green. Selected arrow flashes 3 times. Arrows with stored 
codes light for 1 second, then sleep mode.
Arrow Position Deletion After pressing and holding the selected arrow position for 5 seconds.
Center button flashes red 6 times, then sleep mode. After the UP position arrow is selected for deletion.Arrow Position Deletion Failed - Primary Code
Center button white. Awaiting New Code Entry After center button pressed to enter new code.
Center button lights white and arrows flash with each press. Code Entry During new code entry.
Center button fades in and out white in 1 second. Repeats until any but-
ton is pressed or timeout is reached.
Awaiting Code Confirmation Waiting for code confirmation entry.
Center button green. Selected arrow flashes 3 times. Arrows with stored 
codes light for 1 second, then sleep mode.
Code Accepted When confirmation code matches initial code.
Center button flashes magenta 6 times, then sleep mode. Code Rejected - Invalid When new code is invalid.
Center button flashes red 3 times, then sleep mode. Code Rejected - Does Not Match When confirmation code does not match initial code.
©2016 Master Lock Company LLC  •  92200 Neuilly-sur-Seine, France
   1.    Open the lock using the Primary or Backup Master Code.
  2.   Press and hold the center button for 2 seconds. Center button lights white indicating 
program mode. 
  3.   Each arrow position with a stored code lights blue. 
  4.   Press the arrow where a new code will be stored or  
an existing code will be changed or deleted. 
  5.   Press the center button. The selected arrow from step 4 blinks twice.
HOW TO CHANGE THE BATTERY
1.   Unlock the lock and pull the shackle up.
2.  Pull out the battery drawer  
  and remove the old battery. (Fig. B)
3.   Install a new CR2032 battery with the  
positive (+) side facing the (+) cutout  
in the drawer (down).
4.   Close the battery drawer.
HOW TO USE THE BATTERY JUMP SLOT 
 *   If battery voltage is insufficient to unlock the 
lock, pull out the battery drawer to expose 
the battery jump slot (Fig. C). Do not force 
the drawer open further. It will not extend 
fully with the lock in the locked position. 
Hold a new CR2032 battery in the jump 
slot with positive (+) side of battery facing 
toward the lock face and start at step 1 
above.
**   Program mode cannot be accessed when 
the lock is powered by a battery in the jump 
slot.
P49915
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may 
cause undesired operation. This Class B digital apparatus complies with Canadian ICES-003. 
For Backup Master Code, visit masterlockvault.com  
and enter Vault® Product Code at right.
Pour le Code Master de secours, visitez le site masterlock.com et 
saisissez le code produit Vault
® indiqué à droite.
Den Notfall-Mastercode erhalten Sie auf der Website von 
masterlockvault.com nach Eingabe des rechts angegebenen  
Vault®-Produktcodes.
Primary Code
Code primaire
Administratorcode
Vault® Product Code
Code Produit Vault®
Vault® Produktcode
QUICK START  
GUIDE
   6.  If adding or changing a code:
 7.   Select a new code, between 4-12 
positions in length, using directions,  
letters, or numbers. (Fig. A) 
  8.  Enter that code by pressing the  
        corresponding arrows.
  9.  Press the center button.
  10.   Re-enter the code entered in step 8 to confirm code.
  11.  Press the center button.
  12.   Repeat steps 2-11 to program additional codes.
  13.    Save your codes below or store them safely at: www.masterlockvault.com.
        _____________________________________________________________
If deleting a Guest Code:
Press and hold the selected arrow for  
5 seconds until center button lights green. 
Code deletion is complete.
Jump Slot 
Fente de la pile 
Batterieschlitz
Fig. C
1.   OPEN THE LOCK PRIMARY CODE the first time with the factory-set   above, by pressing the 4 corresponding arrow 
buttons in the sequence shown. Do not pull on the shackle when entering the code.
2.  When the center button lights green, open the lock within 5 seconds or it will relock.
HOW TO ADD, CHANGE, OR DELETE CODES 
IMPORTANT! Steps must be performed within 5 
seconds of each other or lock will time out and 
go into sleep mode. 
Primary Code is always stored in the UP arrow position 
and can only be changed, not deleted. Guest Codes 
can only be stored in the RIGHT, DOWN or LEFT arrow 
positions and can be changed or deleted. (Fig. A)
www.masterlock.eu
Figure 1 represents the requirements not to dispose of WEEE as unsorted municipal aster and to collect such waste separately
For private households: Information on Disposal for Users of WEEE This symbol (figure 1) on the product(s) and / or accompanying 
documents means that used electrical and electronic equipment (WEEE) should not be mixed with general household waste. For 
proper treatment, recovery and recycling, please take this product(s) to designated collection points where it will be accepted free 
of charge. Alternatively, in some countries, you may be able to return your products to your local retailer upon purchase of an 
equivalent new product. Disposing of this product correctly will help save valuable resources and prevent any potential negative  
effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please contact 
your local authority for further details of your nearest designated collection point. Penalties may be applicable for incorrect disposal 
of this waste, in accordance with your national legislation. For professional users in the European Union: If you wish to discard  
electrical and electronic equipment (EEE), please contact your dealer or supplier for further information. For disposal in countries 
outside of the European Union: This symbol is only valid in the European Union (EU). If you wish to discard this product please 
contact your local authorities or dealer and ask for the correct method of disposal.
2006/66/EC including amendment 2008/12/EC is the  
European Community Directive on batteries and  
accumulators and waste batteries and accumulators.
Figure 2 indicates “separate collection” for batteries  
and accumulators and battery packs.
WEEE
Figure 1
Battery Directive
Figure 2
1.   With the lock open,   for  . Center button will light press and hold center button 2 seconds white, 
indicating the lock is in program mode. The UP arrow will light, indicating a Primary Code is stored 
there.
2.   Press UP arrow. the   
The UP arrow is the only position 
in which you can program and store the Primary Code.
3.   Press the  . The UP arrow will blink twice, center button
indicating the PRIMARY CODE is ready to be changed.
4.   Enter a   of arrows, letters or new code as a sequence
numbers by pressing the corresponding buttons.  
The sequence must be at least 4 and no more  
than 12 positions in length.
5.   Press white the    It will flash center button. .
6.   Re-enter code the   entered in step 4 to confirm.
7.   Press green the   It will light center button.  to indicate you 
have successfully changed the PRIMARY CODE. Store 
your code at www.masterlockvault.com.
You can use the PRIMARY CODE  
as your everyday code  
or you can change it.
READ THOROUGHLY! Steps must be performed 
within 5 seconds of each other or lock will time 
out and go into sleep mode. 
Center  
Button
Up Arrow
Produktspecifikationer
| Varumärke: | Master Lock | 
| Kategori: | Inte kategoriserad | 
| Modell: | 1500 | 
Behöver du hjälp?
Om du behöver hjälp med Master Lock 1500 ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad Master Lock Manualer
                        
                         15 Oktober 2024
                        
                    
                                                            
                        
                         9 Oktober 2024
                        
                    
                                                            
                        
                         8 Oktober 2024
                        
                    
                                                            
                        
                         4 Oktober 2024
                        
                    
                                                            
                        
                         30 September 2024
                        
                    
                                                            
                        
                         30 September 2024
                        
                    
                                                            
                        
                         29 September 2024
                        
                    
                                                            
                        
                         27 September 2024
                        
                    
                                                            
                        
                         20 September 2024
                        
                    
                                                            
                        
                         17 September 2024
                        
                    
                                                            Inte kategoriserad Manualer
- Zagg
- Jilong
- KitchenAid
- Millecroquettes
- American BioTech Supply
- Coby
- Atlantis Land
- Losi
- Gastroback
- SuperFish
- Lowrance
- BBQ Premium
- Royale
- Burris
- Aerotec
Nyaste Inte kategoriserad Manualer
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025