R A N G E H O O D
INSTALLATION
G U I D E
TABLE OF CONTENTS
Safety Instructions.................................................... 1
Mounting Heights.................................................... 2
Ducting..............................................................3-7-9
Specications...........................................................4
Installation............................................................ 5-6
Form No. A/04/03 Part No. IMK5558-0303A ©2003 Maytag Appliances Sales Co. Litho U.S.A.
Model Number: UXT5230AD* UXT5430AD*
UXT5236AD* UXT5436AD*
Manufacturer Number: MK5500 MK5800
Size: 30” & 36” 30” & 36”

INSTALLATION GUIDE
Read all Instructions before Installing and operating this appliance
MODELS: UXT5230AD* UXT5236AD* UXT5430AD* UXT5436AD*
Installation
The installation in this manual is intended for qualied installers, service technicians or persons
with similar qualied background. DO NOT attempt to install this appliance yourself. Injury could
result from installing the unit due to lack of appropriate electrical and technical background.
All electrical wiring must be properly installed, insulated and grounded. Overly accumulated
grease in old duct work should be cleaned out or duct work should be replaced if necessary to
avoid the possibility of a grease re. Check all joints on duct work to insure proper connection
and all joints should be properly taped.
* Please check for latest specication revisions before any custom work or cutouts.
IMPORTANT SAFETY NOTICE
WARNING

INSTALLATION 2
MOUNTING HEIGHTS
DUCTING
6"
36"
96"
Min 24"-Max 32"
Minimum mounting height between range top
to hood bottom should be no less than 24".
Maximum mounting height should be no high-
er than 32".
It is important to install the hood at the
proper mounting height. Hoods mounted too
low could result in heat damage and re
hazard; while hoods mounted too high will be
hard to reach and will lose performance and
eciency.
If available, also refer to range manufacturer's
height clearance requirements and recom-
mended hood mounting height above range.
A minimum of 6” round or 3-1/4”x10” rectangular
duct must be used to maintain maximum air ow
eciency.
Always use rigid-type metal ducts only.
Flexible ducts could restrict air ow by up to 50%.
Also use calculation (on right) to compute total
available duct run when using elbows, transitions
and caps.
ALWAYS, when possible, reduce the number of
transitions and turns. If long duct run is required,
increase duct size from 6” to 7 or 8”. If a reducer
is used, install a long reducer instead of a pancake
reducer. Reduce duct size as far away from open-
ing as possible.
If turns or transitions are required:
Install as far away from opening and as far
apart, between 2, as possible.
*Minimum clearance of 24” hood above range
height.
** Maximum clearance 32" hood above range
height.
Minimum Duct Size:
Round:
6” minimum
Rectangular:
3-1/4”x10”
Duct Run Calculation:
Maximum run
6” or 3-1/4” x 10” duct
Deduct:
each 90 Elbow used
each 45 elbow used
each 6” to 3/14 x 10”
transition used
each 3/14 x 10” to 6”
each 3/14 x 10” to 6”
transition used
Side Wall Cap w/ damper
Roof Cap
100 FT
15 FT
9 FT
1 FT
5 FT
30 FT
30 FT
e.g.- 1 roof cap, 2x90 elbows, 1 45 elbow used:
=30' + 30' + 9' =69' used, 31' available for straight duct runs.

INSTALLATION 3
DUCTING
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or
garages. All exhaust must be ducted to the outside.
Use Metal ductwork only.
Fasten all connections with sheet metal screws and tape all joints w/ certied Silver Tape or DuctTape.
Some Ducting Options:
side wall cap
w/ gravity damper
side wall cap
w/ gravity damper
Sot or crawl space
Roof Pitch w/
Flashing & Cap
WARNING FIRE HAZARD

INSTALLATION 4
SPECIFICATIONS
3 1/4"
1 "0
3 " 3 "0or 6
6"
6"
7 3/4"
3 " 3 "0or 6
1 / "5 5 8
1 1/4"0
1 3/4" 1"
22 1/4"
4 1/4"
C L/
C L/
1/ " 2Elec. K.O.

INSTALLATION 5
MOUNTING THE RANGEHOOD
ELECTRICAL
All Electrical work must by performed by qualied electrician or person with similar technical
know how and background.
For personal safety, remove house fuse or open circuit breaker before beginning installation.
Do not use extension cord or adapter plug with this appliance.
Follow National electrical codes or prevailing local codes and ordinances.
Electrical Supply:
This appliance requires a 120V 60Hz electrical supply, connected to an individual, properly grounded
branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2
wire w/ ground. Please also refer Electrical Diagram labeled on product.
Cable Lock:
A cable locking connector (not supplied) might also required by local codes. Check with local
requirements and codes, purchase and install appropriate connector if necessary.
Cable Lock
WARNING

INSTALLATION 6
MOUNTING THE RANGEHOOD
1. This range hood is mounted under a
kitchen cabinet unit.
2. Select preferred duct location on rear or
top of unit. For ductless conversion, no
ducting is required.
3. Begin installation by temporarily removing
the diuser and lter panels.
4. Temporarily position the range hood in
the desired mounting location.
Measure and mark the mounting holes,
duct and electrical access locations with
a pencil.
5. Drill/cut out the required openings for
duct and electrical access; make sure the
duct opening is large enough to apply
duct tape.
6. Fasten mounting screws onto
cabinet as marked, do not tighten,
leaving half length of screws exposed.
7. Install electrical.
8. Hang hood onto screws through key
holes, and tighten.
9. Install duct work and duct-tape.
10. Reinstall the difuser panels.
11. Power up hood and check for leaks
around duct-tape.
duct/silver
tape

INSTALLATION 7
CONVERTIBLE OPTIONS
This range hood is equipped with the option of a 6” vertical discharge, 3 1/4”x10” vertical discharge,
or 3 1/4”x10” rear discharge. Additional accessories are provided to convert to either of the above
discharge methods.
Convertible Options
Vertical discharge 6” round
Vertical discharge 3 1/4”x10”
Horizontal rear discharge 3 1/4”x10”
Convertible Accesories
Round to rectangular transition adaptor
Rectangular to round transition adaptor
Gasket (pre-mounted)
Rectangular rear cap (pre-mounted)
3 1/4”x10” starting collar
3 1/4”x10” Vertical Discharge
1. Remove pre-mounted 6” transition adaptor or duct
opening. Leave attached gasket in its original place.
3. Mount the 3-1/4”x10” starting collar on top of
transition piece with remaining screws.
2. Place rectangular transition adaptor as shown over
gasket and by rst installing 4 screws on half round
section.
(pre-mounted)

INSTALLATION 8
CONVERTIBLE OPTIONS
3 1/4”x10” Rear Discharge
1. At rear of range hood, remove all screws on pre-
mounted rear rectangular cap and remove cap.
5. Mount starting collar (provided) at rear discharge
opening with gasket.
4. Mount rectangular cap (previously removed) on top
of transition adaptor.
3. Mount rectangular transition piece at opening with
gasket as shown.
2. Remove top pre-mounted transition piece. Leave
attached gasket in its original place.
Produktspecifikationer
Varumärke: | Maytag |
Kategori: | Fläktkåpa |
Modell: | UXT5230ADW |
Behöver du hjälp?
Om du behöver hjälp med Maytag UXT5230ADW ställ en fråga nedan och andra användare kommer att svara dig
Fläktkåpa Maytag Manualer

15 Oktober 2024

13 September 2024

13 September 2024

13 September 2024

13 September 2024

13 September 2024

13 September 2024

13 September 2024

13 September 2024

13 September 2024
Fläktkåpa Manualer
- Fläktkåpa Fulgor Milano
- Fläktkåpa FAURE
- Fläktkåpa Viva
- Fläktkåpa Airforce
- Fläktkåpa SEIKI
- Fläktkåpa Sauter
- Fläktkåpa Hotpoint-Ariston
- Fläktkåpa Baumatic
- Fläktkåpa Frigidaire
- Fläktkåpa Constructa
- Fläktkåpa JennAir
- Fläktkåpa Sirius
- Fläktkåpa Blanco
- Fläktkåpa Bertazzoni
- Fläktkåpa Samus
Nyaste Fläktkåpa Manualer

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025