    Läs gratis den bruksanvisning för Mitsubishi MSZ-GS60VFD (8 sidor) i kategorin Luftkonditionering. Guiden har ansetts hjälpsam av 11 personer och har ett genomsnittsbetyg på 4.8 stjärnor baserat på 6 recensioner. Har du en fråga om Mitsubishi MSZ-GS60VFD eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
                        Sida 1/8
                    
                    
                    
JG79J919H01 Required Tools for Installation
Phillips screwdriver
Level
Scale
Utility knife or scissors
75 mm hole saw
Torque wrench
Wrench (or spanner)
4 mm hexagonal wrench
Flare tool for R32, R410A
Gauge manifold for R32, R410A
Vacuum pump for R32, R410A
Charge hose for R32, R410A
Pipe cutter with reamer
SPLIT-TYPE AIR CONDITIONERS
INSTALLATION MANUAL
ENGLISH
Model names are indicated in 1-3.
REFRIGERANT
Appropriate personal protective equipment
The installer should ensure they check the respective Work Health 
and Safety (WHS) Act within their jurisdiction as the requirements 
and obligations may differ.
1.  BEFORE INSTALLATION
MEANINGS OF SYMBOLS DISPLAYED ON INDOOR UNIT AND/OR OUTDOOR UNIT
WARNING
5LVNRI¿UH
7KLVXQLWXVHVDÀDPPDEOHUHIULJHUDQW
,IUHIULJHUDQWOHDNVDQGFRPHVLQFRQWDFWZLWK¿UHRUKHDWLQJSDUWLWZLOOFUHDWHKDUPIXOJDVDQGWKHUHLVULVNRI¿UH
Read the OPERATING INSTRUCTIONS carefully before operation.
Service personnel are required to carefully read the OPERATING INSTRUCTIONS and INSTALLATION MANUAL before operation.
Further information is available in the OPERATING INSTRUCTIONS, INSTALLATION MANUAL, and the like.
1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
•  Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing the air conditioner.
 %HVXUHWRREVHUYHWKHZDUQLQJVDQGFDXWLRQVVSHFL¿HGKHUHDVWKH\LQFOXGHLPSRUWDQWLWHPVUHODWHGWRVDIHW\
•  After reading this manual, be sure to keep it together with the OPERATING INSTRUCTIONS for future reference.
•  When using this product in Australia, carefully read the Australian Institute of Refrigeration and Flammable refrigerants Safety Guide in Air conditioning and Heating (AIRAH) as well.
 CAUTION
 WARNING
■  Do not install the unit by yourself (user).
 ,QFRPSOHWH LQVWDOODWLRQ FRXOG FDXVH ¿UH HOHFWULF VKRFN
injury due to the unit falling, or leakage of water. Consult 
the dealer from whom you purchased the unit or a quali-
¿HGLQVWDOOHU
■  Perform the installation securely referring to the in-
stallation manual.
 ,QFRPSOHWH LQVWDOODWLRQ FRXOG FDXVH ¿UH HOHFWULF VKRFN
injury due to the unit falling, or leakage of water. 
■  When installing the unit, use appropriate protective 
equipment and tools for safety.
  Failure to do so could cause injury.
■  Install the unit securely in a place which can bear the 
weight of the unit.
  If the installation location cannot bear the weight of the 
unit, the unit could fall causing injury.
■  Do not alter the unit.
 ,WPD\FDXVH¿UHHOHFWULFVKRFNLQMXU\RUZDWHUOHDNDJH
■  (OHFWULFDOZRUNVKRXOGEHSHUIRUPHGE\DTXDOL¿HG
experienced electrician, according to the installation 
manual. Be sure to use an exclusive circuit. Do not 
connect other electrical appliances to the circuit.
 ,IWKHFDSDFLW\RIWKHSRZHUFLUFXLWLVLQVXI¿FLHQWRUWKHUH
LVLQFRPSOHWHHOHFWULFDOZRUNLWFRXOGUHVXOWLQD¿UHRUDQ
electric shock.
■  Earth the unit correctly.
  Do not connect the earth to a gas pipe, water pipe, light-
ning  rod,  or  telephone  earth.  Defective  earthing  could 
cause electric shock.
■  Do  not  damage  the  wires  by  applying  excessive 
pressure with parts or screws.
 'DPDJHGZLUHVFRXOGFDXVH¿UHRUHOHFWULFVKRFN
■  Be sure to cut off the main power in case of setting 
up the indoor P.C. board or wiring works.
  Failure to do so could cause electric shock.
■ 8VH WKH VSHFL¿HG ZLUHV WR FRQQHFW WKH LQGRRU DQG
RXWGRRUXQLWVVHFXUHO\DQGDWWDFKWKHZLUHV¿UPO\WR
the terminal block connecting sections so the stress 
of  the  wires  is  not  applied  to  the  sections.  Do  not 
extend the wires, or use intermediate connection.
 ,QFRPSOHWHFRQQHFWLQJDQGVHFXULQJFRXOGFDXVH¿UH
■  'RQRWLQVWDOOWKHXQLWLQDSODFHZKHUHLQÀDPPDEOH
gas may leak.
  If gas leaks and accumulates in the area around the unit, 
it could cause an explosion.
■  Do  not  use  intermediate  connection  of  the  power 
cord or the extension cord and do not connect many 
devices to one AC outlet.
 ,WFRXOGFDXVHD¿UHRUDQHOHFWULFVKRFNGXHWRGHIHFWLYH
contact, defective insulation, exceeding the permissible 
current, etc.
■  %HVXUHWRXVHWKHSDUWVSURYLGHGRUVSHFL¿HGSDUWV
for the installation work.
  The use of defective parts could cause an injury or leak-
DJHRIZDWHUGXHWRD¿UHDQHOHFWULFVKRFNWKHXQLWIDOO-
ing, etc.
■  When plugging the power supply plug into the outlet, 
make sure that  there is no dust, clogging, or loose 
parts in both the outlet and the plug. Make sure that 
the power supply plug is pushed completely into the 
outlet.
  If  there  is  dust,  clogging,  or  loose  parts  on  the  power 
supply plug or the outlet, it could cause electric shock or 
¿UH ,IORRVH SDUWVDUH IRXQG RQ WKH SRZHU VXSSO\SOXJ
replace it.
■  Attach the electrical cover to the indoor unit and the 
service panel to the outdoor unit securely.
  If the electrical cover of the indoor unit and/or the service 
panel  of  the  outdoor  unit  are  not  attached  securely,  it 
FRXOG UHVXOW LQ D ¿UH RU DQ HOHFWULF VKRFN GXH WR GXVW
water, etc.
■  When  installing,  relocating,  or  servicing  the  unit, 
make  sure  that  no  substance  other than the speci-
¿HGUHIULJHUDQW5HQWHUVWKHUHIULJHUDQWFLUFXLW
  Any  presence  of  foreign  substance  such  as  air  can 
cause abnormal pressure rise and may result in explo-
sion or injury. The use of any refrigerant other than that 
VSHFL¿HG IRU WKH V\VWHP ZLOO FDXVH PHFKDQLFDO IDLOXUH
system  malfunction,  or  unit  breakdown.  In  the  worst 
case, this could lead to a serious impediment to securing 
product safety.
■  Do  not  discharge  the  refrigerant  into  the  atmos-
phere. If refrigerant leaks  during  installation,  venti-
late  the  room.  Check  that  the  refrigerant  does  not 
leak after installation has been completed.
 ,IUHIULJHUDQWOHDNVDQGFRPHVLQFRQWDFWZLWK¿UHRUKHDW-
ing part of such a fan heater, kerosene heater, or cooking 
stove, it will create harmful gas.
■  Use appropriate tools and piping materials for instal-
lation.
  The  pressure  of  R32  is  1.6  times  more  than  R22.  Not 
using  appropriate  tools or materials  and incomplete  in-
stallation could cause the pipes to burst or injury.
■  When pumping down the refrigerant, stop the com-
pressor before disconnecting the refrigerant pipes.
  If the refrigerant pipes are disconnected while the com-
pressor is running and the stop valve is open, air could 
be  drawn  in and the pressure  in the refrigeration  cycle 
could  become  abnormally  high.  This  could  cause  the 
pipes to burst or injury.
■  When installing the unit, securely connect the refrig-
erant pipes before starting the compressor.
  If the compressor is started before the refrigerant pipes 
are connected and when the stop valve is open, air could 
be  drawn  in and the pressure  in the refrigeration  cycle 
could  become  abnormally  high.  This  could  cause  the 
pipes to burst or injury.
■  )DVWHQDÀDUHQXWZLWKDWRUTXHZUHQFKDVVSHFL¿HG
in this manual.
 ,IIDVWHQHG WRR WLJKW D ÀDUHQXW PD\ EUHDNDIWHU DORQJ
period and cause refrigerant leakage.
■  The  unit  shall  be  installed  in  accordance  with  na-
tional wiring regulations.
■  :KHQXVLQJ D JDVEXUQHU RURWKHUÀDPHSURGXFLQJ
equipment, completely remove all of the refrigerant 
from the air conditioner and ensure that the area is 
well-ventilated.
 ,I WKH UHIULJHUDQW OHDNV DQG FRPHV LQ FRQWDFW LQ ¿UH RU
heating part, it will create harmful gas and there is risk of 
¿UH
■  Do not use means to accelerate the defrosting pro-
cess or to clean, other than those recommended by 
the manufacturer.
■  The appliance shall be stored in a room without con-
tinuously  operating  ignition  sources  (for  example: 
RSHQÀDPHVDQRSHUDWLQJJDVDSSOLDQFHRUDQRSHU-
ating electric heater.
■  Do not pierce or burn.
■  Be aware that refrigerants may not contain an odour.
■  Pipe-work shall be protected from physical damage.
■  The installation of pipe-work shall be kept to a mini-
mum.
■  Compliance  with  national  gas  regulations  shall  be 
observed.
■  Keep any required ventilation openings clear of ob-
struction.
■  In  Australia,  only  technicians  that  possess  the  ap-
propriate license issued by the Australian Refrigera-
tion Council (ARC) should install this product.
■   Install  an  earth  leakage  breaker  depending  on  the 
installation place.
  If an earth leakage breaker is not installed, it could cause 
electric shock.
■  Perform the drainage/piping work securely according 
to the installation manual.
  If there is defect in the drainage/piping work, water could 
drop from the unit, soaking and damaging household goods.
■ 'RQRWWRXFKWKHDLULQOHWRUWKHDOXPLQXP¿QVRIWKH
outdoor unit.
  This could cause injury. 
■  Do not install the outdoor unit where small animals 
may live.
If small animals enter and touch the electric parts inside the 
XQLWLWFRXOGFDXVHDPDOIXQFWLRQVPRNHHPLVVLRQRU¿UH
Also, advise user to keep the area around the unit clean. 
■  Do not operate the air conditioner during interior 
FRQVWUXFWLRQDQG¿QLVKLQJZRUNRUZKLOHZD[LQJ
WKHÀRRU
  Before operating  the air conditioner, ventilate the room 
well after such work is performed. Otherwise, it may cause 
volatile  elements  to  adhere  inside  the  air  conditioner, 
resulting in water leakage or scattering of dew.
(Could lead to serious injury in particular environments when operated incorrectly.)
(Could lead to death, serious injury, etc.)
Produktspecifikationer
| Varumärke: | Mitsubishi | 
| Kategori: | Luftkonditionering | 
| Modell: | MSZ-GS60VFD | 
Behöver du hjälp?
Om du behöver hjälp med Mitsubishi MSZ-GS60VFD ställ en fråga nedan och andra användare kommer att svara dig
Luftkonditionering Mitsubishi Manualer
                        
                         16 September 2025
                        
                    
                                                            
                        
                         16 September 2025
                        
                    
                                                            
                        
                         16 September 2025
                        
                    
                                                            
                        
                         16 September 2025
                        
                    
                                                            
                        
                         16 September 2025
                        
                    
                                                            
                        
                         1 September 2025
                        
                    
                                                            
                        
                         1 September 2025
                        
                    
                                                            
                        
                         31 Augusti 2025
                        
                    
                                                            
                        
                         31 Augusti 2025
                        
                    
                                                            
                        
                         31 Augusti 2025
                        
                    
                                                            Luftkonditionering Manualer
- Tatung
- Berner
- ElectriQ
- Symphony
- Big Ass Fans
- Remeha
- Sanyo
- Itho
- Exquisit
- Osram
- Electroline
- Kogan
- Royal Sovereign
- Becken
- RIDGID
Nyaste Luftkonditionering Manualer
                        
                         20 Oktober 2025
                        
                    
                                                            
                        
                         20 Oktober 2025
                        
                    
                                                            
                        
                         20 Oktober 2025
                        
                    
                                                            
                        
                         19 Oktober 2025
                        
                    
                                                            
                        
                         17 Oktober 2025
                        
                    
                                                            
                        
                         17 Oktober 2025
                        
                    
                                                            
                        
                         16 Oktober 2025
                        
                    
                                                            
                        
                         16 Oktober 2025
                        
                    
                                                            
                        
                         16 Oktober 2025
                        
                    
                                                            
                        
                         13 Oktober 2025