Läs gratis den bruksanvisning för Napoleon Gemini BIPT750RBI (24 sidor) i kategorin Utegrill. Guiden har ansetts hjälpsam av 17 personer och har ett genomsnittsbetyg på 5.0 stjärnor baserat på 9 recensioner. Har du en fråga om Napoleon Gemini BIPT750RBI eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/24

APPLY SERIAL NUMBER LABEL FROM CARTON
Serial No.
XXXXXX000000
MODEL NO.
N415-0175 APR 17.14
BUILT–IN UNIT INSTRUCTION GUIDE
Please use this manual in conjuncon with your main manual to properly assemble your built-in grill. Refer to
the main manual for operang, cleaning, and maintenance instrucons.
WARNING! This grill is designed for enclosures only, and must be installed and
WARNING!
BUILT IN PROPANE GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping
should be located as shown in the built-in instrucons. A exible metal connector is included to simplify the
installaon of the unit. Connect this exible metal connector to the are ng on the end of the manifold.
Connect the other end of the connector to the gas piping. Ensure that the connector does not pass through a
wall, oor, ceiling or paron, and is protected from damage. Do not use a hose to connect the unit except to
connect the cylinder regulator to the piping system. It must be connected with rigid pipe, copper tube or an
approved exible metal connector which complies with Z21.4 /CSA 6.10.
The installaon must comply with CAN B149.1 Natural Gas and Propane installaon code in Canada, or to the
Naonal Fuel Gas code, ANSI Z223.1 in the United States. The gas supply pipe must be suciently sized to
supply the BTU/h specied on the rang plate, based on the length of the piping run. If installing a side burner,
a separate line must be branched o to the side burner unit and enter the side burner opening at the specied
locaon. If the enclosure is to house a propane cylinder, the tank poron of the enclosure must be venlated
according to local codes, and must not have communicaon with the cavity used to enclose the gas grill. A
propane tank can not be stored below the gas grill.
BUILT IN CYLINDER ENCLOSURES: Built in cylinder enclosures which completely enclose the cylinder must have
both of the following:
1. At least one unobstructed venlaon opening on the exposed exterior side of the enclosure located within
5 in (127 mm) of the top of the enclosure. The opening must have a total free area of more than 20 in
2
(130
cm2)
for a 20 lb (9.1 kg) cylinder and 30 in2 (195 cm2) for a 30 lb (13.6 kg) cylinder.
2. At least one venlaon opening on the exposed, exterior side of the enclosure located 1 in (25.4 mm) or less
from the oor level. The opening must have a total free area of more than 10 in 2 (65 cm2) for a 20 lb (9.1 kg)
cylinder and 15 in2 (100 cm2) for a 30 lb (13.6 kg) cylinder. The upper edge must be no more than 5 in (127
mm) above the oor level.
www.napoleongrills.com
Napoleon Group of Companies
Produktspecifikationer
| Varumärke: | Napoleon |
| Kategori: | Utegrill |
| Modell: | Gemini BIPT750RBI |
Behöver du hjälp?
Om du behöver hjälp med Napoleon Gemini BIPT750RBI ställ en fråga nedan och andra användare kommer att svara dig
Utegrill Napoleon Manualer
8 Januari 2025
8 Januari 2025
27 Oktober 2024
10 September 2024
9 September 2024
8 September 2024
7 September 2024
5 September 2024
5 September 2024
4 September 2024
Utegrill Manualer
- Boretti
- Trisa
- Cloer
- Proline
- Pit Boss
- Morso
- Oklahoma Joe
- Ofyr
- ECS
- Neff
- Supermicro
- Blaze
- G3 Ferrari
- GSI
- Wmf
Nyaste Utegrill Manualer
9 April 2025
5 April 2025
2 April 2025
2 April 2025
2 April 2025
2 April 2025
29 Mars 2025
27 Mars 2025
13 Mars 2025
4 Mars 2025