Läs gratis den bruksanvisning för NGS Fortress Bunker (48 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 13 personer och har ett genomsnittsbetyg på 4.1 stjärnor baserat på 7 recensioner. Har du en fråga om NGS Fortress Bunker eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/48

www.ngs.eu
ENGLISH I FRANÇAIS I ESPAÑOL I DEUTSCH I ITALIANO I PORTUGUÊS
POLSKI I NEDERLANDS I ČEŠTINA I SLOVENČINA I ΕΛΛΗΝΙΚΑ

USER’S MANUAL
2
REMARKS ABOUT SAFETYSAVE THESE INSTRUCTIONS
In order to keep safe in using the UPS, please comply with the
following:
•Pleasechargethebatteryatleast12hoursbeforetheUPSisin
operation.
•Afterthebatteryisdischargedoroverthreemonthswithout
operarion,thebatteryshouldbechargedimmediatelyforatleast
12hours,ensuringthebatteryisfullandavoidinganyunnecessary
damageofthebattery.
•WhenACfailsandtheONbuttononthefrontpanelispressed,
theUPSwilloutputvoltage;iftheOFFbuttononthefrontpanelis
pressed,theUPSwillnotoutputvoltage.
This manual contains important safety instructions. Please follow
all instructions carefully during installation. Read this manual
thoroughlybeforeattemptingtounpack,installoroperate.
CAUTION Topreventtheriskofreorelectricshock,installina
temperature and humidity controlled indoor area, free
ofconductivecontaminants.
CAUTION Riskofelectricshock,donotremovethecover.Nouser
serviceableparts.Referservicingtoqualiedservice
personnel.
CAUTION Riskofelectricshock,hazardouslivepartsinsidethis
UPScanbeenergizedfromthebatterysupplyeven
when the input AC power is disconnected.
CAUTION Risk of electric shock, Battery Circuit is not isolated from
ACinput;hazardousvoltagemayexistbetweenbattery
terminalsandground.Testbeforetouching.
WARNING This is a Class A-UPS Product. In a domestic
environment,thisproductmaycauseradiointerference,
inwhichcase,theusermayberequiredtotake
additional measures.
NOTICE TheUPSisdesignedtobeforusewithcomputer
loads only.
NOTICE Topreventinjury,donotcarrywiththehandleoffront
coverwhenmovingtheUPS.

ENGLISH
3
MODEL SPECIFICATIONS INTRODUCTION
FORTRESSBUNKER 600VA/360W Battery:1x12V/7Ah
1.BatterychargingLed:itlitswhentheUPSispluggedtothemains.
2. Power failure Led: it lits when the UPS detects a power cut.
3.IndicatesoverloadinUPS.AlsoindicatesthattheUPSwillshut
down in less than thirty seconds when there is a power cut.
4.ON/OFFbutton:turnsUPSonando.
Press and release to turn on
Pressandreleasetoturno
MAIN SPECIFICATIONS
Model FORTRESS BUNKER
DCvoltageinbatterymode 12V
Type of load Computer, displayer
Inputvoltage 230V
Inputfrequency 50Hz
Outputvoltage 230V
Outputfrequency 50/60Hz
Power factor PF=0.6 (when input range -35%
to -23%, PF=0.45)
Backup time 5-10minutes(dependsofthe
load)
Transfer time 10ms
Short-circuit protection Circuitbreaker,limitedoutput
currencyininvertermode
Eciency of power >80%ininvertermode
Temperature 0°C ~ 40°C
Humidity 10%~90%
Display LED display: AC, charging,
inverting
312
4
Produktspecifikationer
Varumärke: | NGS |
Kategori: | Inte kategoriserad |
Modell: | Fortress Bunker |
Behöver du hjälp?
Om du behöver hjälp med NGS Fortress Bunker ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad NGS Manualer
23 September 2024
23 September 2024
23 September 2024
22 September 2024
15 September 2024
10 September 2024
9 September 2024
6 September 2024
26 Augusti 2024
16 Augusti 2024
Inte kategoriserad Manualer
- Syma
- Rossum Electro-Music
- Siemon
- Viscount
- Kelty
- Wasp
- Skaarhoj
- Herlag
- Potenza
- Anybus
- Acer
- Petzl
- Gys
- Milestone Systems
- GP
Nyaste Inte kategoriserad Manualer
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025