Oasis R8 Bruksanvisning


Läs gratis den bruksanvisning för Oasis R8 (2 sidor) i kategorin ej kategoriserat. Guiden har ansetts hjälpsam av 2 personer och har ett genomsnittsbetyg på 4.8 stjärnor baserat på 1.5 recensioner. Har du en fråga om Oasis R8 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/2
REMOTE COOLING UNITS
NOT FOR USE WITH R.O. WATER
OASIS
®
R8, R12
SUNROC
RWCD8, RWCD12
INSTRUCTIONS
Inspect the carton and water cooler for evidence of rough handling and concealed damage. Damage claims should be filed
with the carrier.
2. MAINTENANCE
The only maintenance operation required is the removal of dirt and lint from the condenser. Inspection should be made at 3
month intervals. When condenser requires cleaning, remove dirt and lint with a vacuum cleaner. Observance of this
procedure will insure adequate air circulation through the condenser so operation is eicient and economical.
3. OVERLOAD PROTECTION
The compressor motor is equipped with an automatic reset protector which will disconnect the motor from the line in case of
an overload.
4. LUBRICATION
This unit is equipped with a hermetically sealed compressor and requires no additional lubrication. The fan motor on this unit
seldom needs oiling, but if required, a few drops of SAE 10 oil should be used.
5. COOLING UNIT INSTALLATION
a) Note: The following states require a licensed plumber to install cooler; AR, GA, MA, MI, OK, RI, SC, SD, TX, VT and WI.
CA, KS, MN, NM and OR allow for a state-registered installer or contractor as well. State and local plumbing codes may
prohibit the use of saddle tapping valves for water line connection in some applications. All connections must conform to
applicable plumbing codes.
b) This unit is a remote water cooling package suitable for mounting in most locations.
CAUTION: If located in a recess or alcove, the ventilated sides of the cooling unit requires a minimum of 5 clearance
from walls. This unit is not intended for cabinet or under-sink installation.
c) Locate and install plumbing and electrical service in accordance with the dimensional drawing.
d) Connect water supply tube from WATER-IN tube on cooling unit to the shut-o valve. If a lter is to be installed, place it
in-line between the shut-o valve and the WATER-IN tube on the cooling unit.
e) A lter kit is available for retrofit to this system. Refer to kit instructions for installation. WARNING: Do not flush
lter until WATER-OUT connection is made. A bracket or clip can be used to secure the lter. Refer to the Rough in
and Dimensional Drawing of the unit in which the filter is to be installed for specics on use and location. Pre-punched
holes are already located where the lter will be mounted.
f) Make connection to WATER-OUT tube on cooling unit.
g) Flush lter per instructions listed on the Oasis Versalter Cartridge Replacement Instructions sheet.
h) Check the available power supply against the cooling unit data plate to assure correct electrical service. Make service
connections to the outlet box.
i) Turn on power and water supply to the cooling unit. After cooling unit has lled as evidenced by the absence of the
audible lling sound, draw o water until no air bubbles are seen in the water stream.
6. TO DISCONTINUE USE OF COOLING UNIT
a) Disconnect power supply.
b) Close water supply shut-o valve.
c) Provide container to catch water and remove drain plug from cooling unit.
d) Replace plug when draining is complete.
e) ALWAYS DRAIN ALL WATER WHEN FREEZING TEMPERATURES ARE ANTICIPATED AND BEFORE
SHIPPING THE COOLING UNIT.
WARNING
The warranty and the Underwriters' Laboratories listing for this machine are automatically voided if this machine is altered,
modied, or combined with any other machine or device. Alteration or modication of this machine may cause serious ooding
and/or hazardous electrical shock or fire.
EXCEPT AS SET FORTH HEREIN, THE MANUFACTURER MAKES NO OTHER WARRANTY, GUARANTEE OR
AGREEMENT EXPRESSED, IMPLIED OR STATUTORY, INCLUDING ANY IMPLIED WARRANTY OR
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
222 East Campus View Blvd. Columbus, OH 43235 U.S.A.
1-800-950-3226
www.oasiscoolers.com
OASIS is a registered trademark of LVD Acquisition, LLC dba Oasis International 030099-246 Rev J
A WBENC Certied Womens Business Enterprise © 2014 LVD Acquisition, LLC


Produktspecifikationer

Varumärke: Oasis
Kategori: ej kategoriserat
Modell: R8

Behöver du hjälp?

Om du behöver hjälp med Oasis R8 ställ en fråga nedan och andra användare kommer att svara dig